Showing results: 1366 - 1380 of 6560 items found.
-
McLAREN Applied Technologies
The output of a hall effect sensor is a voltage which changes in proportion to the shaft extension. A constant voltage is required across the supply and ground wires of the sensor. The sensor consists of a Hall Effect element, and a shaft which houses a magnet. When the position of the sensor changes relative to the shaft, the change in magnetic field in the sensor results in a change in output voltage.
-
Yokogawa Test & Measurement Corp.
Instrument transformer is a general term for voltage transformers and current transformers that are used with electrical instruments. The main purpose of instrument transformers is to extend the measurement range for electrical quantities (voltage, current, power, power factor) on large-current and high-voltage circuits. They serve to convert currents and voltages to levels that are suitable for measurement, and to insulate the instrument, etc. from high-voltage circuitry.
-
SY 1065 -
Hong Kong Songyang Industrial Ltd.
This kind of meter integrates many functions into one, realizes the functions of time-sharing electricity measurement for active double-direction, measuring demand, sinusoidal reactive, calculating power factor, displaying and tele-transmitting present voltage, current, power and load curve etc. and it realizes the function of recording all the missing voltage, missing current and the percent of pass for voltage,
-
APCI-2200-16-8 -
TEAM SOLUTIONS, INC.
16 electromechanical relays with change-over contacts ? Max. switching voltage for the relays: 60 V/DC, 48 V/AC ? Max. switching current: 1 A ? Short response time ? Option: 8 input channels for AC voltage, optically isolated, input voltage range: 12 - 24 V DC ? Watchdog: software-programmable release, stop and time selection.
-
Extech MN10 -
Extech Instruments Corporation
The Extech MN10 is an affordable, Pocket Multimeter that is fully loaded with functions such as a built in non-contact voltage (NCV) detector, AC/DC voltage, current, resistance, and a battery test. Its easy-to-use manual ranging design allows you to select the voltage, current, or resistance range you are testing. Perfect for students, DIYs, and entry level electricians.
-
33502A -
Keysight Technologies
The Keysight 33502A is a dual-channel, high voltage output amplifier. It has an isolated analog front end with up to 50 Vpp (25 V) output voltage range. It is also a very low-distortion amplifier with < 0.01% @ 10 kHz and 40 Vpp. The 33502A is designed to work as a companion for function generators to offer low-distortion, higher voltage outputs.
-
810 EL -
Standard Electric Works Co., Ltd
● Wiring check.● Can be used on 2 wires L-E (ELCB/RCCB/GFCI tester).● Can be used on 3 wires L-E-N (with wiring check).● Sense automatically 50 or 60 Hz.● No battery required.● Simple operation.● Current injected in phase with the voltage.● Fused.● Wide operating voltage (195Vac to 265Vac).● Other voltage optional (110V).● Robust.
-
MC133C -
Powertek LLC
The Model MC133C is a compact single housed three phase electric power/energy calibrator. It can supply the device under test with precision one phase AC voltage and current with calibrated phase shift along with DC voltage and current. Output voltage can be set in five ranges up to 280V and output current in six ranges up to 30A.
-
Helmut Fischer AG
Maximum safety with high voltage generation directly in the probe head and low-energy voltage according to ISO 2746Three instrument versions with different test voltage ranges:HV5: 0.8 5 kVHV20: 4 20 kVHV40: 8 40 kVIntuitive operation with menu navigation, rotary push switch and OLED displayExtensive selection of electrodesDisplay of the test voltage applied directly to the electrode Pore detection sensitivity: detection threshold settable to a voltage drop of 10, 20, 30 or 50 %Porosity detector switchable between static and dynamic thresholdBattery operation by means of a Li-ion battery with smart battery technology, a controller monitors the battery state permanently and avoids deep discharge
-
SBF -
Wuhan Sangao Electrical Test Installations Limit Co.
Specificationstripping test transformer1.easy to operate, with stable features.2.Can meet the induced voltage withstand request ofTtripping est transfromer,frequency tripling transformer, frequency tripling generator, frequency power generatorproduct features1.Easy to operate, with stable features.2. Can meet the induced voltage withstand request of the transformer, mutual inductor.product parameters1. Output voltage: three phases 380V 50HZ2. Input voltage: single phase 0~300V/0~500V(continuously adjustable) frequency:150HZ3. Output capacity: 5KVA and above.Harmonic distortion:<5%-8%4. No-load running time:≤5minutes5.duration of the measured equipment under rated voltage: 40 seconds
-
277 HP -
Standard Electric Works Co., Ltd
● 2 ranges for selection ( 2 function buttons ) LOW : 50V~1.5kV Press the LOW button, 277 HP is ready for low voltage detection. HIGH : 1.5kV~132kV Press the HIGH button, 277 HP is ready for high voltage detection.● Power consumption: Off : Less than 5uA Low voltage detection mode: Less than 40mA High voltage detection mode: Less than 40mA● Circuit test function Press the Test button to make sure the whole circuit is working well before testing actual high voltage circuits.● Optional accessory: HS-175 Telescopic hot stick (triangle-type) HS-120 Hot stick
-
-
-
HIOKI E.E. Corp
Non- metalic voltage measurements Non- metalic measure voltage and detect phase sequence simultaneously 90 to 520 V AC 6 - 30 mm (0.24 - 1.18 in) core dia.
-
Advanced Energy
Advanced Energy’s chassis-mount, DC-to-DC, high voltage modules work easily within OEM equipment as component power supplies. Benefit from full-range control and voltage and current monitoring.