Showing results: 1921 - 1935 of 4155 items found.
-
Megger Group Ltd.
The primary test methods used to assess the condition of the active insulation components in transformers and bushings, on site, include:1) power factor/tan δ,2) variable frequency power factor/tan δ (1 - 500 Hz)3) dielectric frequency response (DFR) [a dielectric response method], and4) moisture in oil measurements (for transformers).
-
Bode 100 -
OMICRON Lab
With the multifunctional Bode 100 you get an exact picture of your electronic circuits and components in a frequency range from 1 Hz to 40 MHz. The Bode 100 is not only a state of the art Vector Network Analyzer, it also works as: Frequency Response Analyzer, Impedance Meter, Gain Phase Meter, Sine Wave Generator.
-
Schwarzbeck Mess Elektronik
Helmholtz-Coils are especially designed to generate precisely defined magnetic fields from DC to the upper end of the audio frequency range and beyond. The generated fields are in a strongly linear relation to the coil current. The field- strength can be calculated exactly by analytical (or numerical) methods, based on the coils' geometry, the number of turns and the coil current.
-
Rosenberger Hochfrequenztechnik GmbH & Co. KG
Rosenberger offers the following types of calibration kits with a range of coaxial connector series for vector network analyzers (VNAs). All Rosenberger calibration kits can be used from DC to their maximum frequency. Full version with adaptors and sliding loads for variable measurements Industrial version for standard measurements LRL and TRL version
-
Howard Butler Ltd.
96 x 48mm digital panel meters with 3.5 digit, 14.2mm high 7 segment LED’s. The products offer a wide range of AC or DC input parameters. Essentially there are 3 main product group types:- AC Volts, Amps, Milliamps, DC Volts, Amps, Milliamps, Millivolts, Frequency.
-
XY Plotter -
ZETLAB Company
XY Plotter is used for visualizing (form evaluation) the transfer characteristics of two values to be measured. The following instruments can be used for transfer characteristics: DC and AC voltmeters, a selective AC voltmeter, a frequency meter, and a phase meter. Characteristics can be displayed in 3 planes (XY, XT, and YT), as well as in a three-dimensional (XYT) view.
-
DER EE Electrical Instrument
LCD display3 Digits LCD With 1999 Counts Low Battery Display On LCD Overload"OL" Display On LCD Accuracy(3%+3dgt) at 50Hz./60Hz. Frequency Response30Hz~400Hz Sampling RateApprox. 2.5 times/sec. Max Hold / Data Hold Battery9V x 1 Specifications0.1~200mG (milli Gause)
-
FE-5121 -
Ceibo Inc.
* Emulates AT89C5121 Derivatives with 6/12 Clocks/Cycle * 16K Code Memory * Software Trace * Real-Time Emulation * Frequency up to 16MHz/ 3V, 5V * X1 and X2 Mode Support * MS-Windows Debugger for C and Assembler * Keil mVision2 Debugger Compatible * PLCC-52 and SSOP-24 Emulation Headers * Serially Linked to PC at 115Kbaud
-
GPS120 -
INSTOCK Wireless Components, Inc
Wideband Frequency (1000-2000 MHz)Low Insertion Loss (0.6 dB avg)High Port to Port Isolation (30 dB avg)Excellent VSWR (1.15 : 1 avg)15 VDC & 75 mA Max on DC Block PortsTri Alloy Type N Female (Jack) Low PIM
-
GPS160 -
INSTOCK Wireless Components, Inc
Wideband Frequency (1000-2000 MHz)Low Insertion Loss (0.6 dB avg)High Port to Port Isolation (30 dB avg)Excellent VSWR (1.15 : 1 avg)15 VDC & 75 mA Max on DC Block PortsTri Alloy Type N Female (Jack) Low PIM
-
Schwarzbeck Mess Elektronik
Helmholtz-Coils are especially designed to generate precisely defined magnetic fields from DC to the upper end of the audio frequency range and beyond. The generated fields are in a strongly linear relation to the coil current. The field- strength can be calculated exactly by analytical (or numerical) methods, based on the coils' geometry, the number of turns and the coil current.
-
FMC407 -
Sundance Multiprocessor Technology Ltd.
The FMC407 is a low-noise clock generation and distribution module with eight clock outputs and eight trigger outputs that are fully synchronized. This module can either distribute an externally supplied or a locally generated clock. In the standard configuration, the FMC407 can generate any clock frequency between 34.375 MHZ and 4.4GHz and lock it to an internal or external reference.
-
EB-51X2 -
Ceibo Inc.
* Emulates 8051 Derivatives with 6/12 Clocks/Cycle * 64K Code And 64K Data Memory * Memory With Mapping Capabilities * Real-Time Trace * Frequency Range up to 40MHz * Source-Level Debugger For C And Assembler * MS-Windows Debugger Software * Performance Analyzer * Emulation Header and Signal Testpoints * Serially Linked to IBM PC at 115Kbaud
-
MOX Series -
EM Research, Inc.
*Low phase noise OXCO *Interface between VSAT Modems and Frequency Converters *Robust housing is gasket sealed for weather resistance *OCXO iwth low G-sensitivity available *Single or dual multiplexer *Single or dual bias tee *Available in various OCXO frequencies: 10, 50, 100, 120 MHz
-
Mercury Systems, Inc.
Our family of distributed amplifiers utilize advanced broadband design techniques to achieve solid performance in gain, flatness, noise figure and output power over a wide frequency range. The experienced design team has the know-how and tools available to take any standard product and customize it for your specific application.