Filter Results By:

Products

Applications

Manufacturers

Frequency

number of times waves occur per unit time.

See Also: Gigahertz, Microwave, Terahertz, Band


Showing results: 2956 - 2970 of 4162 items found.

  • Signal Generators

    Aaronia AG

    Whether the BPSG generators with their precisely generated RF signals for testing EMC shielding and EMI/RFI measurements, or the brand new SPECTRAN V6 VSG vector signal generators with a frequency range of 10 MHz - 6 GHz and a large number of modulation types, the Aaronia signal generators impress with their quality and price.

  • Digital Multimeter

    189 DM - Standard Electric Works Co., Ltd

    ● 4000-count LCD.● Auto ranging.● Voltage, Resistance, Continuity, Diode measurement.● Frequency, Capacitance, Current measurement.● Wide range for capacitance test : 0~4000μF.● Data hold function.● Low battery indication.● Over range indication.● Auto power off.● With a convenient stand for viewing.● Compact and lightweight.

  • PCIe-6612, PCI Express, 5 V, 8-Channel Counter/Timer Device

    782351-01 - NI

    The PCIe‑6612 performs encoder position measurement, event counting, period measurement, pulse-width measurement, pulse generation, pulse-train generation, and frequency measurement. It features eight counter/timers, digital debouncing filters, and TTL/CMOS-compatible digital I/O. The PCIe‑6612 can perform three simultaneous high-speed DMA transfers.

  • Digital Multimeter

    DMT-4010RMS - Monacor International GmbH & Co. KG

    *True RMS measurement method*Dust and water protection according to IP class 67 with covered measuring sockets*Auto ranging for faster measurements*4000 digit resolution*Additional bar display*Voltage measurement up to DC/˜ 1000 V*Current measurement up to DC/˜ 10 A*Frequency measurement up to 10 MHz*Resistance measurement up to 40 MΩ*Capacitance measurement up to 40 mF*Temperature measurement -20 °C to +760 °C*Acoustic continuity test*diode test*Data hold (measured value memory)*peak hold*Maximum and minimum value recording*LC display with switchable background lighting*Automatic shutdown*overload protection*Supplied with test leads and protective case

  • Handheld Digital Spectrum Analyzer,

    Seeed Technology Inc.

    Frequency band: 240 - 960 MHz and 2.35 – 2.55 GHzFrequency span: 112KHz - 100MHzGraphics LCD 128x64 pixels, great visibility outdoorsPC Windows client supports Windows XP/Vista/Win7 both 32 and 64bitsBacklight for great indoor visibility2 standard SMA 50 ohms connector, one for Sub-GHz wideband Nagoya NA-773 telescopic antenna included and another one for 2.4GHz band with helical antenna included.Amplitude resolution: 0.5dBmDynamic range: -115dBm to 0dBmAbsolute Max input power: +5dBmAverage noise level (typical): -110dBm2.4GHz RF Generator amplitude: -30dBm to +1dBmFrequency stability and accuracy (typical): +-10ppmAmplitude stability and accuracy (typical): +-3dBmFrequency resolution: 1KhzResolution bandwidth (RBW): automatic 2.6Khz to 600KhzWeight: 185gSize: 113x70x25 mm

  • Leakage Current Clamp Mete

    Nanjing ELIKE Meter Co, Ltd.

    Basic functions:AC current:20mA resolution: 0.01mA, ± (2.5%, +5)200mA resolution: 0.1mA, ±(2.5%, +5)2A resolution: 1mA, ±(2.5%, +5)60A resolution: 100mA, ±(3%, +8)AC voltage: 600V, ±(0.8%, +5)DC voltage: 600V, ±(0.8%, +5)Special functions:Auto ranging Low battery display Data hold Auto power-off Over-load protection Input impedanceDC voltage measurement: ≥10MΩ Sampling frequency: 3 times/s Maximum display: 1999 Maximum distance between clamps: 30mm General characteristics:Product colors: iron-gray and redProduct net weight: approximately 136gLCD size: 25x36mmProduct size: 183x63x29mmPower: 2x1.5V, 7#Standard accessories: packing carton and handheld bag English user's manual and battery

  • RF And Microwave Signal Generation And Analysis

    Sample Technology

    The need for microwave test and measurement technology is even more urgent than the need for microwave equipment itself. Therefore, Shengbo Technology is relying on its own research and development capabilities to strive to become one of the comprehensive microwave test and measurement equipment suppliers. We provide a wide range of RF microwave test products, including a good-quality full-band broadband up-down converter . You can provide 2GHz real-time bandwidth signal up-down conversion function in the frequency range of 0.1 ~ 40 + GHz. With our channel simulator , we Became the first company in the world to provide channel analog solutions in such a wide range of broadband signals. At the same time, we are also an innovativesupplier of noise sources and multi-channel microwave signal sources in the industry.

  • RF Spectrum Analyzers

    RF Explorer - Nuts About Nets, llc

    RF Explorer is a new series of low-cost, portable, RF spectrum analyzers designed by Arocholl that are available in a variety of frequency ranges. Nuts About Nets has been developing diagnostic tools for troubleshooting wireless networks for a number of years and when RF Explorer was first introduced to us we were extremely impressed. The price-performance of these RF spectrum analyzers is truly remarkable and is the best, by far, on the market -- nothing else comes close. These RF analyzers operate both standalone as handheld devices, plus they interface via USB cable to a PC running more sophisticated data acquisition and analysis software. Prices for these RF spectrum analyzers (including PC software) begin at $119 USD -- which is unheard of in the test equipment industry.

  • Tap Adapter

    Techimp HQ S.r.L

    Techimp Voltage Tap Adapter is gender changer which allows the user to connect to the test tap (sometimes called power factor tap) of high voltage transformer bushings.While keeping the test tap well below the safety voltage level required by the manufacturer, the Tap Adapter lets the user to drain high frequency PD signals for diagnostic assessment of insulating materials.A synchronization signal can be derived as well.It is suitable for both single shot as well as continuous PD monitoring.Although it must be customized on the basis of the shape and dimension of the test tap (to be provided by the Customer), many models are readily available for the most established transformer bushings. A list of the presently available models is reported below.Several thousands of hours of operation are a guarantee of reliability and accurate design.

  • Variable Attenuators

    Pasternack Enterprises, Inc.

    Continuously variable attenuators from Pasternack are available in 50 Ohm impedance and with SMA connectors. SMA continuously variable attenuators have RF db attenuation values that range from 7 dB to 40 dB. The frequency range of our continuously variable attenuators is from 1 GHz to 18 GHz. This variable attenuator product line includes low to high power attenuators which have the power handling up to 5 Watts.Variable attenuators from Pasternack include female genders and can be bidirectional, depending on the power rating. Our continuously variable attenuators are manufactured to precise industry specifications and the bodies are constructed of. Pasternack commonly uses Pi attenuators or Pi pads for its continuously variable attenuator designs.

  • Calibration Executive Software

    CalEasy Series - Marvin Test Solutions, Inc.

    CalEasy is a full-featured, Calibration Executive software package that supports the verification and calibration of Marvin Test Solutions instruments. The software is intended for use by users that prefer to perform in-house calibration and verification for their Marvin Test Solutions instruments. By calibrating or verifying the instrument in-house, the time and cost associated with returning an instrument to Marvin Test Solutions for calibration service can be eliminated or reduced. CalEasy is also used internally by Marvin Test Solutions production to perform initial calibration and to recalibrate the instrument when received for service. This ensures that user and factory based calibration performance is similar. Depending on the specific instrument, standards instrumentation supported for calibration / verification includes a DMM, and a frequency standards module. Some modules require the use of matrix switch card.

  • 1226 Auto Switch/Distribution

    Precise Time and Frequency, Inc.

    To complement the range of high quality frequency and timing references, Precise Time and Frequency, Inc. has now introduced a new version of the ptf 1226A Auto Switch that includes an additional switch channel (now 3 channels total) of RF, and/or Digital, and/or Time Code, Auto Switching, and a full Ethernet/RS232 remote monitoring/control interface.In addition to the auto switching capability, the new ptf 1226 delivers up to thirty six channels of RF, Digital or Time Code frequency and/or timing references to critical applications such as Satellite Communications, Broadcasting, WiMax and others.Analog channels include a unique output level monitoring feature to provide remote indication of rms voltage output level.The unit can accept up to three pairs of inputs (usually from separate primary and backup sources), and provides monitoring of both the inputs and outputs for signal integrity. In addition RF channels include analog level monitoring. If the primary input on any auto switch channel fails, the unit will automatically switch to the backup input and indicate a primary signal fault.Full remote monitoring and control via RS232 and Ethernet interfaces includes telnet, http (web browser), and SNMP protocols.

  • Electronic Ballast Tester

    WT4000 - Lisun Electronics Inc.

    • Measure parameter: 1) Input: Vrms, Lrms, W, PF, Hz, Phasic angle, total harmonic and 0-39 component of harmonic. 2) Output: Lamp voltage, Lamp current, Filament current, Guided cathodic current, Lamp power, crest factor and oscillatory frequency, single high frequency analysis. • Startup: Startup lamp voltage, lamp current, filament current, guided cathodic current curve and parameter, preheating time; • Simultaneously display on 8 windows for input and output parameters, convenient for comparison and analysis; • Test preheat energy, filament preheat time. And the parameters changes from 0 to 5s of filament voltage, filament current and filament power; • Up to 1MHz lrms test content to every EB; • Analysis symmetry of high Frequency curve of lout; • 12-bit high-speed A/D, sampling rate up to 10MHz, can easily analyse signal curve of output; • Finish an input and output testing at the same time within 1 minute; • Portable, can test, display, print without computer. Test report include data and curve, comply with international standard; • Communication port for PC, run under Windows98 or Windows2000, English Version available.

  • Hardy Shaker

    HI-903 - Metrix

    This is our top of the line Hardy Shaker. It provides the ability to set the amplitude and change the frequency range without the amplitude changing. This automation makes conducting vibration tests easier. Tests can be conducted on multiple vibration transducers, and then the saved data can be transferred via USB Flash Drive to be displayed in an automated and customizable report using an Excel template on your computer. In manual mode, the vibration test level and test frequency can be set from 7 Hz to 10,000 Hz. The high accuracy instrument can display the vibration level in terms of g’s peak, velocity peak (in/sec or mm/s) or displacement peak-to-peak (mils or µm). The unit can support payloads up to 800 grams (see frequency limits in the manual). A built-in display reads the output sensitivity, which can be stored in memory. Complete testing sequences and data can be stored in memory for each tested sensor, the unit logs the data on the spot or stores it for later use. For testing of heavy transducers or at high frequencies, the HI-903 automatically corrects the sensitivity calculation for the effects of transducer mass loading. A built-in self-test program checks for accuracy of all calculations. The HI-903 has a built-in battery charger that can operate on 120 or 240 VAC. The unit comes in a rugged Pelican case.

  • Leakage Current Clamp Tester

    M-1141 - MULTI MEASURING INSTRUMENTS Co., Ltd.

    ・Auto 5-range : AC 30mA / 300mA / 3A / 30A / 300A・CT inside diameter : φ40mm・Minimum resolution : 0.01mA・Maximum value hold / Data hold function available・Band path filter with center frequency(fo = 55Hz)・Compliant with EN 61010, CAT-III 1000V / CAT-IV 600V・With backlight

Get Help