Showing results: 3541 - 3555 of 4188 items found.
-
346A -
Keysight Technologies
The Keysight 346A noise source is the ideal companion to Keysight's noise figure solutions. Since it is broadband (10 MHz to 18 GHz), it eliminates the necessity for several sources at different frequency bands. The low SWR of the noise source reduces a major source of measurement uncertainty; reflections of test signals. The very small change in reflection coefficient (<0.01) from ON to OFF is designed especially for accurate characterization of input-impedance-sensitive devices (like GaAsFETs and many UHF amplifiers).
-
B1500A -
Keysight Technologies
Current-voltage (IV) measurement capabilities of spot, sweep, sampling and pulse measurement in the range of 0.1 fA - 1 A / 0.5 V - 200 VAC capacitance measurement in multi frequency from 1 kHz to 5 MHz and Quasi-Static Capacitance-Voltage (QS-CV) measurement capabilitiesAdvanced pulsed IV and ultra-fast IV measurement capability from minimum 5 ns sampling interval (200 MSa/s)Up to 40 V high voltage pulse forcing for non-volatile memory evaluation
-
P9400C -
Keysight Technologies
The Keysight P9400C solid state PIN diode transfer switch offers outstanding performance in terms of port-to-port isolation, switching speed and low insertion loss over a broad operating frequency range of 100 MHz to 18 GHz. The P9400C is particularly well suited for ultra-fast RF and microwave switching applications in instrumentation, communications, radar, switch matrices and various other test systems where high isolation, speed and lifetime of a switch is critical.
-
4112 EL -
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● 2 Lines × 16 Characters LCD.● Very low consumption.● Menu-driven.● Accurate digital readout of disconnection time.● Automatic data hold function.● Zero Crossing Circuitry permit testing at 0° or 180°.● Disconnection Phase Polarity Shown on LCD.● Auto off and off override.● Polarity Trip indicator (Positive or Negative Phase).● Wiring polarity indicator.● Measure voltage between line and earth before testing.● Indicates frequency of voltage L-E.
-
40-881-001 -
Pickering Interfaces Ltd.
The 40-881 is a 50 Ohm 6 to 1 6GHz multiplexer available as a single or dual MUX in one and two PXI slots respectively. The 40-881 exhibits low VSWR characteristic over the full operating frequency range and consistent insertion loss characteristics. The use of solid state switches ensure a long service life with no wear out mechanism, making the 40-881 ideal for ATE systems requiring frequent and fast operating RF switching with no contact bounce.
-
40-881-002 -
Pickering Interfaces Ltd.
The 40-881 is a 50 Ohm 6 to 1 6GHz multiplexer available as a single or dual MUX in one and two PXI slots respectively. The 40-881 exhibits low VSWR characteristic over the full operating frequency range and consistent insertion loss characteristics. The use of solid state switches ensure a long service life with no wear out mechanism, making the 40-881 ideal for ATE systems requiring frequent and fast operating RF switching with no contact bounce.
-
Data Patterns Pvt. Ltd.
The Generic RF ATE is developed to test the Radar and Radar Subsystems. The ATE is primarily built using an instrumentation control, precision RF routing systems and rack mounted test instruments. Generic RF ATE system enables measurement of parameters of Radar equipment such as Local Oscillators, Waveform Generators, Up and Down Converters, Analog Receivers, Array Group Receiver Units, TR Modules. The ATE is configured to test the Radars upto 18GHz frequency range.
-
Model 5791 -
Pentek, Inc.
- Simultaneous synthesis of up to five different clocks- Eight SMC clock outputs- Typical phase noise: -105 dBc/Hz @ 1 kHz offset- All clocks are phase-locked to input reference signal- Input reference frequency of 5 to 100 MHz- Four programmable VCXOs with 32-bit tuning resolution- Output clocks of 1, 2, 4, 8, or 16 submultiples of VCXO base frequencies- Output clock frequencies between 50 and 700 MHz- Control and status over the VPX backplane
-
Model 5891 -
Pentek, Inc.
- Simultaneous synthesis of up to 10 different clocks- 16 SMC clock outputs- Typical phase noise: -105 dBc/Hz @ 1 kHz offset- All clocks are phase-locked to input reference signal- Input reference frequency of 5 to 100 MHz- Eight programmable VCXOs with 32-bit tuning resolution- Output clocks of 1, 2, 4, 8, or 16 submultiples of VCXO base frequencies- Output clock frequencies between 50 and 700 MHz- Control and status over the VPX backplane
-
Model 71624 -
Pentek, Inc.
- Modifies 34 IF signals between input and output- Up to 80 MHz IF bandwidth- Two 200 MHz 16-bit A/Ds- Two 800 MHz 16-bit D/As- 34 DDCs and 34 DUCs (digital downconverters and digital upconverters)- Signal drop/add/replace- Frequency shifting and hopping- Amplitude boost and attenutation- PCI Express Gen 1: x4 or x8- RoHS Compliant Lead-Free Version Available- Synchronize up to eight modules with Model 7893 System Synchronization and Distribution Amplifier - PCIe
-
LV-7000 series -
Ono Sokki
The LV-7000 series detects speed, uneven speed, distance, length of moving object or rotating object without contact. By contacting with 2 sensors, it enables to calculate difference in velocity/length between the two points in real time and output with 3,000 ppm of accuracy. The frequency response can be expanded up to 20 kHz, which achieves to understand phenomena and evaluate mechanical systems at high speed, efficiently, and accurately. It is useful for evaluation of motor control and behavior measurement, improving parts quality, and reducing loss of material.
-
MM94 -
Martindale Electric Co. Ltd
The MM94 is a high performance True RMS multimeter with a 600V CAT IV safety rating.
It has an extended current measurement range up to 20A for short cycle measurements. Measurement capabilities include AC/DC voltage, capacitance, resistance and temperature with the included K Type thermocouple. Features include Min/Max and Peak measurement and a high frequency filter to optimise readings for distorted waveforms plus a relative mode.
The rugged design includes a 60,000 count backlit display with analogue bargraph.
-
Series ABC -
Kepco, Inc.
Kepco¹s ABC bench power supply embodies the latest features: keyboard data entry, interactive digital display, integral GPIB support, software calibration, high frequency switch mode conversion, wide range input (85-264V a-c) and power factor correction. It meets the EN 61000-3-2 harmonic limits. A built-in EN 55022 Class B input EMI filter is provided. Integral External Trigger and RS 232 ports are now standard features.
-
FLIR CM46 -
Teledyne FLIR
The FLIR CM46 clamp meter is designed for commercial and residential electricians. Featuring both AC/DC measurement, the meter is equipped with a bright backlit display for use inside electrical panels. Accu-Tip™ technology delivers amperage measurements on smaller-gauged wires more accurately — to a tenth of a digit. The meter also offers MAX/MIN/AVG recording; measures DCµA, temperature, capacitance, and frequency; and has electrical field detection to help you determine voltage presence and relative strength of the field.
-
upj10 -
KEYCOM Corp
KEYCOM''s cryogenic millimeter-wave / microwave test fixtures and calibration kits are specifically optimized for testing the performance of patterns between the edges of printed boards(edge type) and circuit testing on the printed boards(probe type). They are also designed to minimize heat capacity by miniaturizing their dimensions so they cool off efficiently, and materials with low coefficient of linear thermal expansion such as invar are used for major parts where high dimensional stability is required. Their operating frequency ranges from DC to 110GHz.