Showing results: 1651 - 1665 of 4157 items found.
-
EZ-FDTD -
EMS-PLUS
Based on the Finite-Difference Time-Domain method, EZ-FDTD brings the full power of electromagnetics to solve complex EMI/EMC real-world problems for any frequency ranges that your application demands. Eliminate guessing for critical problems. Eliminates rule of thumb uncertainty. Provides insight, confidence and solutions.
-
AC Selective Voltmeter -
ZETLAB Company
AC Selective Voltmeter is used for measuring AC voltage coming to the input channels of ADC modules and FFT spectrum analyzers. The specific feature of the AC selective voltmeter is perfomance of voltage measurements on the main signal-carrier frequency, which allows to eliminate the harmonics influence on the readings.
-
EB-6V -
EverBeing Int'l Corp
The EB-6V probe station is designed for all frequency extenders such as those from VDI, OML, R&S, Keysight, Anritsu. If you are using an Anritsu VNA VectorStar ME7838A4 model, or commonly Anritsu 3743A mmW Extenders and related sizes, the station of interest is the EB-6A.
-
Focus Microwaves
Minimum Noise Figure (Fmin): This is the smallest Noise Figure that the device can reach at a given frequency and bias, if it is optimally matched at the source.Equivalent Noise Resistance (Rn): This is a number with the dimension Ohm that indicates how fast the Noise Figure increases when we mismatch the input (source).
-
HGS01 -
Hangzhou Huatai Optic Tech. Co., Ltd.
*Zinc alloy die-casting chassis, surface with tin plating treatment.*Frequency range: 5-2400MHz. *Shielding degree 40-450MHz ≥ 75dB, 450-860MHz ≥ 65dB, 860-2400MHz ≥ 75dB. *All ports can be passed by maximum voltage: 24V, maximum current: 1A. *75Ω British F-type connector.
-
APC464 -
Acromag, Inc.
Four 16-bit multifunction counters/timers are configurable for pulse width modulated output, watchdog timer, event counter, frequency measurement, pulse width measurement, period measurement, or one shot pulse output. The four 16-bit counters can also be configured into two 32-bit counter/timers.
-
4002 -
Valon Technology, LLC
sThe Valon 4002 Phase Detector module Independently measures both Gain/Loss and Phase between two signals. It is a perfect complement to all our Frequency Synthesizer modules and ideal for many experimental RF applications. The 4002 enhances the performance of the AD8302 base core.
-
5125A -
Microsemi Corporation
The 5125A makes accurate phase-noise measurements on signals from 1 MHz to 400 MHz, covering the full range of the most commonly used frequency references. The 5125A, which requires absolutely no configuration, displays measurement results seconds after the Start button is pressed.
-
EE-120A-3 -
EMSYST Ltd
The Current Source is able to generate three-phase currents, synchronized with the service voltage, with unprecedented stability and measurement accuracy. The amplitude and phase-shift of each current is individually adjustable. The values of voltage, current, power, power factor, phase shift, THD and frequency are indicated on the LCD display.
-
EE-120A-3 + EE-500V-3 -
EMSYST Ltd
The Phantom Load is able to generate three-phase voltages and currents with unprecedented stability and measurement accuracy. The amplitude and phase-shift of each current and voltage is individually adjustable. The generated values of voltage, current, power, power factor, phase shift, THD and frequency are indicated on the LCD display.
-
1287A -
Ametek Scientific Instruments
The Solartron Analytical 1287A potentiostat and galvanostat is a high accuracy, wide bandwidth instrument which offers a range of DC test capabilities. The 1287A can be coupled with a frequency response analyzer, such as the Solartron Analytical 1260A or 1255B, and ZPLOT software for AC tests such as Electrochemical Impedance Spectroscopy.
-
PD2578 -
INSTOCK Wireless Components, Inc
Wideband Frequency (2.4 - 6.0 GHz)Low Insertion Loss (0.5 dB avg)High Port to Port Isolation (22 dB avg)Excellent VSWR (1.20 : 1 avg)Outdoor Weatherproof ConstructionTri Alloy SMA Female (Jack) Low PIM
-
PD2568 -
INSTOCK Wireless Components, Inc
Wideband Frequency (2.4 - 6.0 GHz)Low Insertion Loss (0.4 dB avg)High Port to Port Isolation (20 dB avg)Excellent VSWR (1.25 : 1 avg)Outdoor Weatherproof ConstructionTri Alloy SMA Female (Jack) Low PIM
-
PD2558 -
INSTOCK Wireless Components, Inc
Wideband Frequency (2.4 - 6.0 GHz)Low Insertion Loss (0.3 dB avg)High Port to Port Isolation (25 dB avg)Excellent VSWR (1.15 : 1 avg)Outdoor Weatherproof ConstructionTri Alloy SMA Female (Jack) Low PIM
-
AMZC-304 -
Amperis sl
Short circuit loop impedance measurement in networks with nominal voltage: 220/380V, 230/400V, 240/415V, with frequency 45…65Hz ; Short circuit loop impedance measurement with 15mA current, without triggering RCD. ; Detection of the replacement L and N in the socket and automatic swap in the meter