Filter Results By:

Products

Applications

Manufacturers

Frequency

number of times waves occur per unit time.

See Also: Gigahertz, Microwave, Terahertz, Band


Showing results: 1366 - 1380 of 4162 items found.

  • 1.533 Μm Frequency-Locked Laser

    Thorlabs, Inc.

    Thorlabs' LLD1530 Frequency-Locked Laser is a narrow linewidth, DFB-laser-diode-based, turnkey system with a vacuum emission wavelength of 1532.8323 nm and a high SMSR of at least 35 dB. The laser frequency is actively stabilized to a National Institute of Standards and Technology (NIST)-traceable molecular transition of acetylene and has an absolute accuracy at start-up that is better than ±25 MHz. The emission frequency immediately after start-up is then maintained with a ±25 MHz stability, providing an overall frequency accuracy of ±50 MHz. The LLD1530 is an accurate frequency reference designed to provide low-noise laser emission with excellent frequency stability, accuracy, and precision immediately at start-up. This source is ideal for use in demanding FTIR instrumentation, instrument calibration, gas sensing, and coherent telecommunications applications.

  • Rubidium Instruments

    Quartzlock (UK) Ltd.

    Our range of atomic / rubidium disciplined time and frequency standards in a variety of enclosures and sizes to suit all appliations. These acurate time and frequency references are used in telecoms, aviation, nautical and precision test and measurement enviroments.

  • Rubidium Oscillators

    Quartzlock (UK) Ltd.

    Our range of atomic / rubidium disciplined time and frequency standards in a variety of enclosures and sizes to suit all appliations. These acurate time and frequency references are used in telecoms, aviation, nautical and precision test and measurement enviroments.

  • DC Filter Inductors

    Osborne Transformer Corp.

    Osborne DC filter inductors (aka filter chokes) are commonly used in AC to DC conversion circuits to present an inductive voltage drop to the AC component of rectified current. This inductive voltage drop acts as a filter. Osborne designs filter inductors to  components to function effectively (without saturation) in the presence of the DC current. Osborne will work with you to mitigate the impact of ripple frequency in conversion circuits. Every Osborne DC filter choke is designed for high performance with special consideration given to your circuit´s power supply frequency and conversion configuration.

  • Linear Accelerometers

    Columbia Research Laboratories

    Columbia Research Labs line of Force Balance Linear Accelerometers offers low cost, high performance, general purpose single axis accelerometers that are ideal for DC and low frequency measurements, with both voltage and current signal outputs available. Also offered are Columbia's Solid State Sensors and our specialized Airborne Sensors that generate outputs specifically designed to operate from +24 to +32VDC aircraft power, that is excellent for airborne telemetry applications. And our Low Noise Sensors are designed for use in seismic, low level, low frequency motion studies.

  • PTP Grandmaster

    OSA 5335 - Oscilloquartz sa

    Our OSA 5335 Modular PTP Grandmaster is a scale-able and high-performance IEEE 1588 v2 standard compliant Grandmaster Clock for the distribution of frequency, phase and time synchronization over packet-based network infrastructure including IP/MPLS, Carrier Ethernet, PON and DSL networks. Its carrier-class design provides high client capacity and a wide range of redundancy options to deliver scale-able performance and maximum availability. Our OSA 5335 is designed to deliver precise and reliable frequency, phase and time-of-day information in markets including telecommunications, media broadcast and power utility communications.

  • TV Signal Generator

    Eiden Co., Ltd.

    This device is equips with the simulator. The following condition can be simulated. Non Liner: Non-linear assumed the satellite repeater - AWGN: C/N assumed the rain attenuation.- Phase Noise: Phase noise assumed the LNB - Frequency Drift: Frequency drift assumed the LNB- Echo: Reflection by the reception wiring and so on The MPEG-2 TS and the TLV (Type Length Value) can be transmitted. The test stream generator is equipped. Thus, the files can be rewritten through the USB2.0 interface. A seven-inches WVGA touch-panel is equipped. Thus, an excellent operation ability is provided. The remote control through the Ethernet is possible.

  • Wideband Power Analyzer

    2335A - Clarke-Hess Communications Research

    The Model 2335A Wideband Power Analyzer is a precision, high accuracy, high frequency auto-ranging instrument which measures and displays true rms Voltage, true rms Current, and true mean Power over a frequency range from dc to more than 1MHz. Full scale Current and Voltage inputs are typically measured within 0.1% of the amplitude reading to at least 500kHz. The corresponding Power is typically measured to within 0.1% of the input Volt-Amperes to 250kHz and to within 0.2% of the input Volt-Amperes to 500kHz for loads having any Power Factor.

  • Precision LCR Meter (20Hz to 1MHz)

    ST2827 - Saluki Technology Inc.

    ST2827 series precision LCR meter has multiple functions and higher test frequency. With small size and portable appearance, it is convenient for use on the shelves. This instrument has a basic accuracy of 0.05%, maximum test frequency of 1MHz and resolution of 10 mHz. ST2827 series is easy to operate with a 4.3-inch LCD screen as well as English operation interfaces. Integrated transformer test function greatly improve the test efficiency. The instrument is also provided with multiple interfaces which can meet various requirements of the automatic sorting test, data transmission and storage.

  • 30MHz Arbitrary Waveform Signal Generator

    Model AWG30D - Aplab Limited

    - 4.3′ High Resolution TFT LCD Display- Two Independent Channels Output, Same Characteristic- 1μHz Frequency Resolution for whole range- 120 MSa/s Sampling Rate, 14 Bits Vertical Resolution- 5 Standard Waveforms, 50 Built-in and 5 User-defined Arbitrary Waveforms- FM, AM, PM, PWM, Sum, FSK, BPSK and SUM Modulation, Sweep and Burst Function- Channel Coupling and Combine Features On CHB- Build in 350MHz Frequency Counter- Arbitrary Waveform Edit PC Software- Standard Interface: USB Host, USB Device and RS-232

  • Radar Electronic Support Receiver

    RR024 - Teledyne Defence & Space

    The RR024 is designed for Radar Electronic Support (RES) and Radar Warning Receiver (RWR) applications where high performance and small size are of prime importance, with filtering, amplification, detection and pulse parameter measurement being combined into one multi-function unit. Four amplitude measurement channels allow direction finding by amplitude comparison between adjacent antennas. An IFM, fed from one of the amplitude channels via an SPDT switch, performs 14 bits of frequency measurement on the selected input. Frequency resolution is nominally 1 MHz over a 2 to 18 GHz band.

  • Varactor Tuned Gunn Oscillators

    ERAVANT

    Varactor tuned Gunn oscillators utilize high performance GaAs Gunn diodes and various cavity configurations to deliver moderate output power with low AM/FM noise and harmonic emissions. The oscillators are specially designed for a broader tuning bandwidth and an electrical tuning capability. The standard offering covers the frequency range of 8.2 to 110 GHz and features a self-locking set screw for fine frequency setting. While standard models offer a waveguide interface, a coaxial interface is also available. The performance of the oscillator can be further enhanced by adding an isolator, Gunn oscillator modulator/regulator, and temperature heater.

  • Full Band Phase Shifters

    STP-18-10-M2 - ERAVANT

    Full band phase shifters are micrometer-driven, waveguide-based phase shifters. The configuration of the micrometer-driven phase shifters is similar to that of level setting attenuators, where the phase shifting is caused by an E-plane dielectric insert in the rectangular waveguide. The amount of phase shifting is directly dependent on the volume of the insert. The VSWR and the insertion loss of these phase shifters are dependent on the frequency. The below standard offering covers the frequency range of 18 to 110 GHz and a phase shifting range of 180 degrees. These micrometer-driven phase shifters are typically used to introduce a certain amount of phase shifting when the absolute number is not a focus.

  • Precision LCR Meter

    TH2827C - Changzhou Tonghui Electronic Co., Ltd.

    TH2827 series is a new precision LCR meter with various functions and a higher test frequency. With small size and portable appearance, it is convenient for use on the shelves. This instrument has a basic accuracy of 0.05%, maximum test frequency of 1MHz and resolution of 10 mHz. It is easy to operate with a 4.3-inch LCD screen as well as selectable Chinese and English operation interfaces. Integrated transformer test function  greatly improve the test efficiency. The instrument is also provided with multiple interfaces which can meet various requirements of the automatic sorting test, data transmission and storage.

  • 6U Processor Board

    VP62107 - LinkedHope Intelligent Technologies Co.,Ltd.

    VP62107 supports Intel® Xeon-D Processors up to D-1577(16x 1.3GHz). Based on Broadwell microarchitecture, Xeon® Processor D-1577 possessor has 16 computing cores sharing 24MB L3 Cache, and its base operating frequency is 1.3GHz. VP62107 also supports Intel Turbo (automatic overclocking) technology enabling CPU maximum operating frequency up to 2.7GHz. By using Turbo technology of VP62107, users do not have to increase the cost or complexity of the system configuration just to meet the demand of system peak computing performance.

Get Help