Showing results: 721 - 735 of 2295 items found.
-
IVCAD MT930 Series -
Maury Microwave Corporation
IVCAD advanced measurement and modeling software, offered by Maury Microwave and AMCAD Engineering supports multiple load pull techniques including traditional load pull using external instrumentation, VNA-based load pull, active load pull and hybrid load pull. It performs DC-IV and pulsed-IV measurements and incorporates device modeling tools. Its modern visualization capabilities give users a greater ability to view, plot and graph measurement data in an intuitive manner.
-
National Technical Systems
To determine the failure point or break strength, you will need to define what a break is (break detector). Generally, there are two common types of breaks: the sharp break is referred to the measurement when load or force drops by 5% from its peak load measurement. A percentage break is another form of break and is generally determined by the sample material and its relationship to load degradation from a peak load measurement. A plastic material will likely have a load drop of 5%, but not represent a break. In this case, a percentage break would need to be applied. In a tensile test, the breaking load is the break strength.
-
Series G -
Teledyne Defense Electronics Relays & Coax Switch
Series G relays are designed for medium-power loads. The design incorporates a thyristor output. Series G relays utilize optical isolation to protect the control from load transients. An internal MOV is also provided to protect against load transient voltages. The compact size makes it ideal for designs where space is limited. Zero-Cross and Random switching options available.Available options include:G24R12-06 12Arms, 12-320Vrms, 520Vpeak Load; 3-32Vdc Control; RandomG24D12-06 12Arms, 12-320Vrms, 520Vpeak Load; 3-32Vdc Control; Zero-Cross
-
LXinstruments GmbH
An electronic load offers the possibility of testing the specimen under different loads. Various load changes are simulated, as they can occur in normal operation. For this purpose, the relevant load current is set in a defined range and electronically controlled. For the test, different operating states are either programmed or entered into the system via an interface (USB, RS-232, GPIB...). For easy handling and quick use, there are four operating modes.
-
-
Holding Informtest
Measure current using either "Average responding" meters reading linear loads or "True RMS" meters measuring non linear loads.
-
SUBT-3.0 -
Dynamic Load Monitoring Ltd.
The Subsea Tensile Link is specially designed for working in subsea conditions and is used for measuring tensile loads. With an optional integral 4-20mA amplifier the load cell is packaged in a wooden case with a subsea rated signal cable to customer specific lengths or alternatively can be supplied with a TW-3.0-S display. Fully sealed with a subsea connector and pressure tested to over 250Bar the load cell is the ideal instrument for easily and accurately measuring subsea loads.
-
PI-41400 -
Pulse Instruments
The PI-41400 is a dual channel Clock Driver card capable of operating up to 190 MHz into a 50-ohm load and up to 80 MHz at an amplitude of 8 volts into a 1-megohm load. Into a high impedance load the output voltage range is from a –3 volts to 8 volts with the output pulse amplitude ranging from 0.5 V to 9 V. When driving a 50 load the voltage range is –1.5 volts to 4.5 volts with the output pulse amplitude ranging from 0.25 V to 4.5 V. The rise and fall times of the output pulse are variable from 1.2 ns to 9 ns into a 50-ohm load and <5 ns to 9 ns into a HiZ load. The output pulse amplitude and the load being driven determine the range of variability. The driver output can be set for tri-state operation and the output polarity can be set for ‘Normal’ or ‘Inverted’ operation through software.
-
LQ404 -
Computer Gesteuerte Systeme GmbH
The qualification tester LQ402 is designed to support up to 12 DUTs (Device under Test), for which the loads are installed in separate load boxes. The system consists out of 3 cabinets. One is for the electronic components with the primary measurement devices and the other two hold the 12 load boxes.
-
LQ402 -
Computer Gesteuerte Systeme GmbH
The qualification tester LQ402 is designed to support up to 6 DUTs (Device under Test), for which the loads are installed in separate load boxes. The system consists out of 2 cabinets. One is for the electronic components with the primary measurement devices and the other one holds the 6 load boxes.
-
Series DH -
Teledyne Defense Electronics Relays & Coax Switch
Series DH relays are designed for all types of loads. These relays feature our new high efficiency back-to-back thyristors for long lifetime expectancy. The relays utilize optical isolation to protect the control from load transients. All relays offer a green control LED and Zero-Cross switching.Available options include:DH24D25 25A, 12-280Vrms, 600Vpeak Load; 3-32Vdc ControlDH24D35 35A, 12-280Vrms, 1200Vpeak Load; 3-32Vdc Control
-
AW Dynamometer, Inc.
AW is the world leader in AG/PTO dynamometers with over 14,000 units sold. AW's hydraulic activated load unit is water cooled allowing it to test high torque loads for continuous periods of time. AW's heavy duty load units are well known to last for decades. Combine this with all new computerized electronic load control, software, thermocouples, sensors and you have a system second to none - the AG.X Series.
-
515 -
Clarke-Hess Communications Research
The Model 515 High Accuracy AC Reference Generator fills a need for a relatively low cost and practical solution for supplying a reference excitation to typical LVDT and Synchro/Resolver transducers. The Model 515 has built-in load sensing which, in effect, yields "zero" output impedance and virtually eliminates the effects of fluctuating output loads. With up to 15 VA of output into loads with as much as 80 of phase shift, the Model 515 is ideally suited to driving inductive loads.
-
Series CD -
Teledyne Defense Electronics Relays & Coax Switch
The CD series Solid-state Relay utilizes the latest technology to provide a low ON resistance. The control circuit is buffered to enable the relay to be driven directly from standard CMOS or open collector TTL logic circuits. Available options include short circuit protection and current overload protection or a status output line.MSL 1CD relays are controlled by 3.8-6VdcC = Through-hole mount SC = Surface mountAvailable options include:CD00CF 2A, 60Vdc LoadSCD00CF 2A, 60Vdc LoadCD01CF 2A, 60Vdc Load; control statusSCD01CF 2A, 60Vdc Load; control statusCD20CD 1A, 60Vdc Load; short-circuit protectionSCD20CD 1A, 60Vdc Load; short circuit protectionCD21CD 1A, 60Vdc Load; short-circuit protection & control statusSCD21CD 1A, 60Vdc Load; short circuit protection & control status
-
spriteCloud