Filter Results By:

Products

Applications

Manufacturers

Loads

test full state.

See Also: Load Boards


Showing results: 991 - 1005 of 2309 items found.

  • Low Profile Solid State Relays, Utilizing MIL-PRF-28750 Test Methods

    Series KD and LD - Teledyne Defense Electronics Relays & Coax Switch

    Your product description goes here.​Series KD and LD solid-state relays utilize MIL-PRF-28750 test methods and are packaged in low-profile hermetically sealed cases. They feature fully floating power FET output technology. Options include short-circuit and current overload protection plus a status output line. Switch status returns the true status of the output switch and is optically isolated from the load.MSL 1KD & LD relays are controlled with 15mAdc/3.8Vdc (TTL), and 1mAdc/0.3Vdc (CMOS).Available options include:KD00CK 5Adc, 60Vdc Load KD02CK 5Adc, 60Vdc Load; with switch status​​KD20CK 5Adc, 60Vdc Load; with short circuit protectionKD22CK 5Adc, 60Vdc Load; short circuit protection & switch statusLD00CM 10Adc (5Adc without heat sink), 60Vdc LoadLD02CM 10Adc (5Adc without heat sink), 60Vdc Load; with switch status​​LD20CM 10Adc (5Adc without heat sink), 60Vdc Load; with short circuit protectionLD22CM 10Adc (5Adc without heat sink), 60Vdc Load; short circuit protection & switch status

  • Emergency Battery Test Fixture

    TA-60 - Tech-Aid Products

    This test fixture will allow servicing of the 60-1321-( ) series of emergency exit light power supply. These supplies are used in many aircraft to annunciate exit lighting when aircraft power failure occurs. The TA-60 test fixture is equivalent to the suggested test fixture in the OEM 60-1321 CMM. The four load lamps are conveniently placed behind an acrylic red lens for proper viewing while performing load test. The bench cable is provided as part of the test fixture.

  • Loop Calibrator

    Model KM CAL-904-MK1 - Kusam Electrical Industries Limited

    • 4-20mA (1kΩ Load, 24V Loop Output).• 0-20mA and 0-24mA output ranges.• 0.025% Basic Accuracy.• Auto Ramp and Step functions.• 0-100% output with percentage step option.• 0-24V DC voltage source.• Open loop and overload buzzer alarm.• Low battery indication.• Simple Operation Interface• Warning beeper when output is open• Pollution Degree 2.• Ambient temperature 0~40℃.• Power Consumption 150mA at 24V 1kΩ load

  • Phase Monitors

    North Atlantic Industries

    NAI''s AC- and DC-powered Phase Monitors are used to protect three-phase loads from damage due to phase reversals or phase absence. Contacts may be used to disconnect the load or to operate alarm circuits or both. Upon application of power, the output relay energizes if all phases are connected and the phase sequence is ABC. If any phase becomes disconnected or if the phase rotation is abnormal, the relay immediately de-energizes. These monitors are specifically designed for rugged defense and industrial applications.

  • Single Phase AC ISSRs

    Series DRS - Teledyne Defense Electronics Relays & Coax Switch

    Series DRS relays are designed for all types of loads. These relays feature our new high efficiency back-to-back thyristors for long lifetime expectancy. The relays utilize optical isolation to protect the control from load transients. These relays are​ Zero-Cross switching.Features Include:• AC Semiconductor Contactor with Diagnostic• Compact size and DIN rail mounting• Zero Cross switch ON in case of overvoltage• Large control range: 3-32Vdc• IP20 housing• UL conformity

  • Solid-State Relay with Power FET Switch to Protect Against Overload and Short-Circuit Currents

    Part No. SR75-2 - Teledyne Defense Electronics Relays & Coax Switch

    The SR75-2 solid-state relay utilizes a power FET switch that is protected against overload and short-circuit currents. The short-​circuit protection feature not only provides protection should a short or overload occur while the relay is on, but will provide protection should the relay be switched into a short. It comes in through-hole or surface-mount 16-pin DIP packages.MSL 6Available options include:SR75-2 0.5Adc, 400Vdc Load; 3.8-32Vdc Control; through-hole mountSR75-2S 0.5Adc, 400Vdc Load; 3.8-32Vdc Control; surface mount

  • PXI Single 8x2 1-Pole 10A Power Matrix

    40-551-002 - Pickering Interfaces Ltd.

    Used for switching inductive/capacitive loads up to 10A with 125VDC/250VAC hot switching and 400VDC/250VAC cold switching. X and Y connections are made via a 20-way GMCT plug, the 8x4 module with loop-thru has an additional 20-way GMCT plug for module-to-module connection. Power Matrix Modules are intended for switching heavy AC or DC loads or for slaving large external relays, contactors and solenoids. Suitable for applications requiring switching of either mains voltage or direct current.

  • PXI Single 8x4 1-Pole 10A Power Matrix

    40-551-001 - Pickering Interfaces Ltd.

    Used for switching inductive/capacitive loads up to 10A with 125VDC/250VAC hot switching and 400VDC/250VAC cold switching. X and Y connections are made via a 20-way GMCT plug, also available with loop-thru has an additional 20-way GMCT plug for module-to-module connection. Power Matrix Modules are intended for switching heavy AC or DC loads or for slaving large external relays, contactors and solenoids. Suitable for applications requiring switching of either mains voltage or direct current.

  • PXI Single 4x4 1-Pole 10A Power Matrix

    40-551-003 - Pickering Interfaces Ltd.

    Used for switching inductive/capacitive loads up to 10A with 125VDC/250VAC hot switching and 400VDC/250VAC cold switching. X and Y connections are made via a 20-way GMCT plug, the 8x4 module with loop-thru has an additional 20-way GMCT plug for module-to-module connection. Power Matrix Modules are intended for switching heavy AC or DC loads or for slaving large external relays, contactors and solenoids. Suitable for applications requiring switching of either mains voltage or direct current.

  • Electronic Circuit Breaker Unit

    Astronics Corporation

    The CorePower® DC or AC Electronic Circuit Breaker Unit replaces conventional thermal mechanical circuit breakers and functions as both a breaker and a switch for controlling loads. By placing ECBUs closer to loads, aircraft manufacturers gain a significant reduction in wire weight, need fewer system components, and lower installation labor costs while increasing safety, efficiency, and reliability. This new smaller unit requires less space and provides more flexible mounting options.

  • PXI Functional Test System

    U8989A - Keysight Technologies

    The TS-8989 PXI functional test system is an integrated, all in one switch, load and measurement system in a box for high voltage or current mechatronics functional test applications of up to 104 nodes and 40A current loads.

  • Power Supply

    NZXT HALE90 850w - Rexus Corp.

    *80+ Gold certified: The HALE 90 series from NZXT operates atultra high efficiency, at 20%, 50% and 100% loads, efficiencies are87%, 90%, and 87% respectively.*Single140mm two ball-bearing fan operates with minimal noiseeven at full load. Maximum decibel levels are 20db for wattagesbetween 550-750W and 30db for 850W and above.*Strong Single Rail Design: A single +12V rail provides stabilityand ease of use making the most out of your power supply. Offers stable & clean current delivery under heavy load.*Modular cable design: Modular cable design allows the user topick and choose which cables they want to use, optimizing cablemanagement and airflow inside the chassis. Flat cables allow for easier routing and bending inside the computer chassis during wire management.

  • Power Supply

    NZXT HALE90 1000w - Rexus Corp.

    *80+ Gold certified: The HALE 90 series from NZXT operates atultra high efficiency, at 20%, 50% and 100% loads, efficiencies are87%, 90%, and 87% respectively.*Single140mm two ball-bearing fan operates with minimal noiseeven at full load. Maximum decibel levels are 20db for wattagesbetween 550-750W and 30db for 850W and above.*Strong Single Rail Design: A single +12V rail provides stabilityand ease of use making the most out of your power supply. Offers stable & clean current delivery under heavy load.*Modular cable design: Modular cable design allows the user topick and choose which cables they want to use, optimizing cablemanagement and airflow inside the chassis. Flat cables allow for easier routing and bending inside the computer chassis during wire management.

  • Pressure Switches

    Kobold Instruments, Inc.

    Pressure switches are built for industrial gas and compatible low-viscosity fluid applications. These pressure-operated switches are ideal for uses demanding a rugged, robust design. Environmental protection is provided by a high-grade IP67 (NEMA 6) enclosure, and the internal design provides excellent resistance to shock and vibration. Both the KAS and KPS Series feature SPDT switches with a DC contact rating of 125V, 12W. The KAS Series pressure switch has an AC contact rating of 250V, 0.1A inductive load. The KPS Series pressure switch has an AC contact rating of 440V, 6A inductive load and 440V, 10A resistive load. Many conventional, as well as some unconventional, requirements for outdoor and indoor use are covered by KOBOLD KAS and KPS Series pressure switches.

  • Platforms

    PENKO Engineering B.V.

    At PENKO we can design and manufacture custom-made platforms of any size and weighing capacity which are suited to your requirements. Our wide range of platforms come in various sizes and weights, with dimensions from 300mm x 300mm to 2m x 3m and weight capacities from 3kg to 6000kg. A platform is the combination of a framework or a top and bottom frame, one load cell or four load cells and a cover. As the load cell / cells are integrated, it offers a measuring system that is immediately ready for use. PENKO’s range of industrial platforms includes dimensions from 150mm x 150mm up to 4 x 1.5m and weighing capacities from 0 – 3kg up to 0 – 6.000kg. The finish takes in stainless steel or mild steel, coated, place.

Get Help