DL6404 -
Di-Log
The top of the range DL6404 provides True RMS reading on AC current and AC voltages allowing accurate measurement regardless of the wave form. This makes it the ideal instrument for commercial and industrial applications where non linear loads are present.
-
FIXUROOF 300 -
Com-Ten Industries
The Fixuroof portable pull-tester is an accurate unit, designed for testing in the field the pull-out force of base ply fastener. Easily determine whether the mechanical fastener provides sufficient resistance to static uplift force to meet the wind load requirements.
-
IMADA, Incorporated
Desktop force/displacement testers record both force and displacement. Programming is facilitated by the unique program dial using plain language menu screens.The jog movement moves the sensor .05mm for each click of the program dial (under no load).
-
1043 -
The Eastern Specialty Company
The Current Transformer Burden Test Set (Catalog No. 1043) is a simple and inexpensive means whereby a current transformer installation may be quickly checked for many sources of trouble. The tests are made without interrupting the customer’s service and while the load is on.
-
Iris Power LP
Rotor magnetic flux variations are the result of the degradation of the rotor winding insulation by mechanisms like load cycling, thermal aging and contamination. Iris Power provides solutions for measuring the magnetic flux in the generator in order to plan maintenance requirements.
-
imc Test & Measurement GmbH
Development test stands from imc are characterized by high flexibility in electric motor trials. A comprehensive variety of motor types can be tested and a complete range of tests carried out. The mechanical configuration consists of a test bed with a load machine and a torque measuring shaft. The load machine and torque sensor shaft are mounted on a linear guide and precisely aligned axially by means of laser. It can be moved towards the test object on ball bearings, as a complete unit. Especially time-saving: no need to realign the load machine assembly when changing the torque sensor.
-
imc Test & Measurement GmbH
Development test stands from imc are characterized by high flexibility in electric motor trials. A comprehensive variety of motor types can be tested and a complete range of tests carried out. The mechanical configuration consists of a test bed with a load machine and a torque measuring shaft. The load machine and torque sensor shaft are mounted on a linear guide and precisely aligned axially by means of laser. It can be moved towards the test object on ball bearings, as a complete unit. Especially time-saving: no need to realign the load machine assembly when changing the torque sensor.
-
JMeter™ -
The Apache Software Foundation
Apache JMeter may be used to test performance both on static and dynamic resources (Webservices (SOAP/REST), Web dynamic languages - PHP, Java, ASP.NET, Files, etc. -, Java Objects, Data Bases and Queries, FTP Servers and more). It can be used to simulate a heavy load on a server, group of servers, network or object to test its strength or to analyze overall performance under different load types. You can use it to make a graphical analysis of performance or to test your server/script/object behavior under heavy concurrent load.
-
Axe Technology Corp.
Accuracy 0.05% F.S.±1digitMeasuring DCA/DCV/ACA/ACV/Potentiometer/Pt-100/Thermocouple/Load Cell/Resistor/etc...Input type J/K/T/E/R/S/B can be modifiedProgrammable rate -19999~99999 digitDecimal point can be modifiedDimension small and High stability CE EMC certification
-
TE Connectivity Ltd.
TE Connectivity (TE) enables OEMs to measure force using MEMS-based technology load cells. The same proprietary piezoresistive silicon strain gage technology used to measure pressure can also be configured into a reliable, low-cost package to measure force.
-
Fuel Cell Technologies, Inc
The Fuel Cell Test Stations provides control of flow, temperature and pressure for the anode and cathode gases. The station incorporates a DC electronic load. The Station also includes two humidity bottles, an Operating Manual and a computer utilizing LabView-based software.
-
Hanatek Instruments
Small, lightweight and durable the gloss meter can be used in production and laboratory environments. The high specifications, including statistical analysis, graphical analysis and software-free PC down load facility make it the ideal gloss meter for matt to mirror surface finishes
-
Hilkar
The widespread use of nonlinear loads such as power electronics based equipment and electric arc & ladle melt furnaces all around the world hinder the quality of electric power. One of the most important parameters for defining the power quality is harmonic distortion.
-
TC 1.3kW to 3.5kW -
ET System Electronic GmbH
*Inverters up to 3500 VA*Quartz stabilized output ± 0.5%*Overload capacity up to 300%*Intelligent standby circuit*Adjustable load detection*EMC tested according to EN 61000-6-3 / 61000-6-1*Modified versions on request
-
Q Series -
Reliance Controls Corp.
The Pro/Tran Q Series features 1-inch interchangeable circuit breakers. A 30A double-pole circuit breaker and a 20A double-pole circuit breaker, to handle heavier loads on the generator side, are included on each model. The balance of the circuit breakers are single-pole 15A.