Showing results: 661 - 675 of 2309 items found.
-
MOHT-400B Open loop method -
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Hall effect measurement for DC/AC/Pulsed current.*For the use of UPS, batteries, switching power supply, DC motor drivers, etc.
-
MOHT-500B Open loop method -
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Hall effect measurement for DC/AC/Pulsed current.*For the use of UPS, batteries, switching power supply, DC motor drivers, etc.
-
MOHT-200B Open loop method -
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Hall effect measurement for DC/AC/Pulsed current.*For the use of UPS, batteries, switching power supply, DC motor drivers, etc.
-
MOHT-800B Open loop method -
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Hall effect measurement for DC/AC/Pulsed current.*For the use of UPS, batteries, switching power supply, DC motor drivers, etc.
-
MOHT-1000B Open loop method -
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Hall effect measurement for DC/AC/Pulsed current.*For the use of UPS, batteries, switching power supply, DC motor drivers, etc.
-
MOHT-1500B Open loop method -
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Hall effect measurement for DC/AC/Pulsed current.*For the use of UPS, batteries, switching power supply, DC motor drivers, etc.
-
MOHT-600B Open loop method -
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Hall effect measurement for DC/AC/Pulsed current.*For the use of UPS, batteries, switching power supply, DC motor drivers, etc.
-
MOHT-1200B Open loop method -
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Hall effect measurement for DC/AC/Pulsed current.*For the use of UPS, batteries, switching power supply, DC motor drivers, etc.
-
LD400 Series -
Aim-TTi
Versatile solution for testing dc power sourcesConstant current, resistance, conductance, voltage and power modesWide voltage and current range, 0 to 80V and 0 to 80A400 watts continuous dissipation at 28°C (360W at 40°C)600 watts short-term dissipation (up to 60 seconds)Low minimum operating voltage of <1V at 40AHigh resolution and accuracy for level settingBuilt-in transient generator with variable slewCurrent monitor output for waveform viewingVariable drop-out voltage for battery testingHigh resolution backlit graphic LCD with soft key controlAnalogue remote control of levels and TTL control of on/off and transient switchingFront and rear input terminals (front terminals 30A max.)Full bus control via USB, RS232 and LXI compliant LAN interfaces (LD400P)GPIB option (LD400P only)
-
6036B-24 -
Associated Equipment Corp.
• Same features as Model 6036B • PLUS the added value of 24 Volt battery testing capacity• Made in USA of US and Global Components
-
MODEL TMO-2 -
Transducer Techniques, Inc
The TMO-2 Transducer Modules is a complete differential amplifier/signal conditioners with self contained power. The units provide excitation, balance and span adjustment via precision 10 turn pots, and shunt calibration necessary to couple a user supplied bridge type transducer to an indicating instrument. Full scale output is specified at plus or minus 10 VDC. The TMO-2 provides a floating shunt calibration circuit which applies calibration at the transducer, thereby eliminating errors due to line losses. The excitation supply incorporates a Wagner Ground to greatly improve Common Mode Rejection. The factory set bandwidth of the module is narrow to improve stability for applications such as weighing scales. The removal of a single capacitor will increase the frequency response DC to 60K Hz for dynamic data applications.
-
MODEL TMO-2A -
Transducer Techniques, Inc
The TMO-2A Transducer Modules is a complete differential amplifier/signal conditioners with self contained power. The unit provide excitation, balance and span adjustment via precision 10 turn pots, and shunt calibration necessary to couple a user supplied bridge type transducer to an indicating instrument. Zero to full scale output is specified at 4-20 mA. The TMO-2A provides a floating shunt calibration circuit which applies calibration at the transducer, thereby eliminating errors due to line losses. The excitation supply incorporates a Wagner Ground to greatly improve Common Mode Rejection. The factory set bandwidth of the module is narrow to improve stability. The removal of a single capacitor will increase the frequency response DC to 60K Hz for dynamic data applications.
-
Aarohi Embedded Systems Pvt. Ltd
Aarohi introduced fully automatic routine testing panel. The primary purpose of the routine test is to insure freedom from electrical and mechanical defects, and to demonstrate by means of key tests the similarity of the motor to a “standard” motor of the same design. this panel also help to enhance productivity, Work efficiency & reduces need for skill operator.
-
Aarohi Embedded Systems Pvt. Ltd
Aarohi introduced fully automatic routine testing panel. The primary purpose of the routine test is to insure freedom from electrical and mechanical defects, and to demonstrate by means of key tests the similarity of the motor to a “standard” motor of the same design. this panel also help to enhance productivity, Work efficiency & reduces need for skill operator. More then 500 Indian pump manufacturer ware installed this system & satisfied with performance.
-
PLZ6000R -
Kikusui Electronics Corp.
PLZ6000R is a DC electronic load that regenerates load power to the AC line. Regular electronic loads consume load power by having semiconductor devices convert it into heat. By contrast, PLZ6000R converts load power into reusable electric power, rather than converting it into heat as is typically done, and feeds this power to the AC line, thereby substantially reducing the amount of waste energy. PLZ6000R is an environment-friendly electronic load that can contribute significantly to your energy saving efforts.