Showing results: 1636 - 1650 of 2295 items found.
-
DT3 -
North Atlantic Industries
The DT3 module (the enhanced version) feature 4 independent, high current, isolated, programmable channels that can be used for input voltage measurements (±100 V), or as a bi-directional current switch (up to 3 A per channel). When programmed as a switch with the switch closed, both the current through the switch and the voltage across the switch can be monitored. These modules include diode clamping on each channel. Clamping is useful for inductive loads, such as relays and short circuit protection.
-
40-661-101 -
Pickering Interfaces Ltd.
The 40-661 is a single pole power multiplexer module, suitable for switching inductive/capacitive loads up to 10A with 125VDC/250VAC hot switching and 400VDC/250VAC cold switching. The multiplexer is available in 8-bank 4-channel, 5-bank 6-channel, 4-bank 8-channel, 2-bank 16-channel and 1-bank 32-channel formats. Also, 4-bank 4-channel, 2-bank 8-channel and 1-bank 16-channel half density configurations are available. Signal connections are made via front panel mounted 20-way GMCT plugs.
-
40-661-003 -
Pickering Interfaces Ltd.
The 40-661 is a single pole power multiplexer module, suitable for switching inductive/capacitive loads up to 10A with 125VDC/250VAC hot switching and 400VDC/250VAC cold switching. The multiplexer is available in 8-bank 4-channel, 5-bank 6-channel, 4-bank 8-channel, 2-bank 16-channel and 1-bank 32-channel formats. Also, 4-bank 4-channel, 2-bank 8-channel and 1-bank 16-channel half density configurations are available. Signal connections are made via front panel mounted 20-way GMCT plugs.
-
40-661-004 -
Pickering Interfaces Ltd.
The 40-661 is a single pole power multiplexer module, suitable for switching inductive/capacitive loads up to 10A with 125VDC/250VAC hot switching and 400VDC/250VAC cold switching. The multiplexer is available in 8-bank 4-channel, 5-bank 6-channel, 4-bank 8-channel, 2-bank 16-channel and 1-bank 32-channel formats. Also, 4-bank 4-channel, 2-bank 8-channel and 1-bank 16-channel half density configurations are available. Signal connections are made via front panel mounted 20-way GMCT plugs.
-
40-661-103 -
Pickering Interfaces Ltd.
The 40-661 is a single pole power multiplexer module, suitable for switching inductive/capacitive loads up to 10A with 125VDC/250VAC hot switching and 400VDC/250VAC cold switching. The multiplexer is available in 8-bank 4-channel, 5-bank 6-channel, 4-bank 8-channel, 2-bank 16-channel and 1-bank 32-channel formats. Also, 4-bank 4-channel, 2-bank 8-channel and1-bank 16-channel half density configurations are available. Signal connections are made via front panel mounted 20-way GMCT plugs.
-
40-661-002 -
Pickering Interfaces Ltd.
The 40-661 is a single pole power multiplexer module, suitable for switching inductive/capacitive loads up to 10A with 125VDC/250VAC hot switching and 400VDC/250VAC cold switching. The multiplexer is available in 8-bank 4-channel, 5-bank 6-channel, 4-bank 8-channel, 2-bank 16-channel and 1-bank 32-channel formats. Also, 4-bank 4-channel, 2-bank 8-channel and 1-bank 16-channel half density configurations are available. Signal connections are made via front panel mounted 20-way GMCT plugs.
-
40-661-102 -
Pickering Interfaces Ltd.
The 40-661 is a single pole power multiplexer module, suitable for switching inductive/capacitive loads up to 10A with 125VDC/250VAC hot switching and 400VDC/250VAC cold switching. The multiplexer is available in 8-bank 4-channel, 5-bank 6-channel, 4-bank 8-channel, 2-bank 16-channel and 1-bank 32-channel formats. Also, 4-bank 4-channel, 2-bank 8-channel and 1-bank 16-channel half density configurations are available. Signal connections are made via front panel mounted 20-way GMCT plugs.
-
40-661-005 -
Pickering Interfaces Ltd.
The 40-661 is a single pole power multiplexer module, suitable for switching inductive/capacitive loads up to 10A with 125VDC/250VAC hot switching and 400VDC/250VAC cold switching. The multiplexer is available in 8-bank 4-channel, 5-bank 6-channel, 4-bank 8-channel, 2-bank 16-channel and 1-bank 32-channel formats. Also, 4-bank 4-channel, 2-bank 8-channel and 1-bank 16-channel half density configurations are available. Signal connections are made via front panel mounted 20-way GMCT plugs.
-
Algodue elettronica
UEM1P5-4D R for RS485 Modbus RTU/ASCII communicationUEM1P5-D M for M-Bus communicationUEM1P5-4D E for Ethernet (Modbus TCP) communicationFor 1 or 5A CTProgrammable CT ratioFully bi-directional four quadrants measurements for all energies and powersFor 3 / 4 wire networks with balanced or unbalanced load (UEM1P5-4D R and UEM1P5-4D E only for 4 wire networks)Class B according to EN 50470-3S0 output for energy pulse emissionAvailable with MID certification
-
40-661-001 -
Pickering Interfaces Ltd.
The 40-661 is a single pole PXI power multiplexer module, suitable for switching inductive/capacitive loads up to 10A with 125VDC/250VAC hot switching and 400VDC/250VAC cold switching. The multiplexer is available in 8-bank 4-channel, 5-bank 6-channel 4-bank 8-channel, 2-bank 16-channel and 1-bank 32-channel formats. Also, 4-bank 4-channel, 2-bank 8-channel and 1-bank 16-channel half density configurations are available. Signal connections are made via front panel mounted 20-way GMCT plugs.
-
Abstracta
Ensure your system is robust and reliable enough to handle peak loads.If your site is running slow or your system is down, you’re losing money. Using the right tools and best practices for your business, our performance engineers help to avoid system failures for websites, APIs, and mobile apps through load testing, stress testing, performance monitoring, and more. Learn more about our performance testing services below.
-
Teledyne Marine Webb Research
The Slocum glider configuration allows you to balance energy consumption, speed, deployment conditions and sensor load. All parameters are user configurable. Webb Research can help you optimize your glider for your unique mission requirements. The Slocum G2 glider offers two energy options, alkaline or lithium primary. Full set includes (1) Pitch battery set, (1)Aft battery set, (2) Nose battery sets.
-
AMETEK Sensors, Test & Calibration
Our reference sensors can be used as your daily working-reference sensors in laboratory or field calibration applications. A large selection of types are available, including; straight, 90 degree angle, 4 mm or 1/4”. The superior design and specifications combined with a long history of reliability and low drift have made the STS probes the working-standard in many EN/IEC 17025 accredited laboratories worldwide. The DLC sensors are a part of our patented Dynamic Load Compensation system.
-
MBT 1000 EUROSYSTEM | VP 610012 -
Maschinenbau Haldenwang GmbH & Co. KG.
The MBT 1000 EUROSYSTEM roller brake tester is used to test the brakes of single and two-lane vehicles such as motorcycles, trikes and quads with a wheel load of up to 1.0 t. Due to its short roller spacing, it is also especially suitable for testing small two-wheelers. Its MAHA modular design enables an optional motorcycle clamping and holding device for the rear and front wheel, whose removable clamping jaws ensure simple and rim-friendly testing.
-
Torch -
Teledyne LABS
The Torch is considered the premium TOC combustion analyzer due to its many useful features and automated analysis processes. For example, it makes serial dilutions of stock standards to form a calibration curve and auto-dilute samples with concentrations above the calibration curve. The Torch software has built-in diagnostic and troubleshooting capabilities. For a luxury but affordable TOC combustion analyzer that you can just load and walk away, look no further than the Torch. You won't regret it!