Showing results: 571 - 585 of 2309 items found.
-
MODEL DPM-3 -
Transducer Techniques, Inc
The DPM-3 is a smart Plug & Play TEDS IEEE 1451.4 compliant Digital Panel Mount Load Cell meter. Just plug in a TEDS compatible Load Cell or Torque Sensor and the DPM-3 will automatically self-calibrate. When used with a non-TEDS Load Cell or Torque Sensor, the DPM-3 can be set up by simple front panel push buttons. The DPM-3 can be scaled to a full 5 digit display from 0 to 99,999 counts to read directly in engineering units such as grams, ounces, pounds, etc. The DPM-3 samples 60 readings per second (50 for 50Hz operation) for fast control response and true peak/valley reading capability. The meter has an adaptive digital filter that can automatically select the best time constant for minimum noise, yet respond rapidly to an actual change in signal level. The peak and valley values can be displayed by a push of a button on the front panel. Auto-tare allows the meter to be set to zero for any input signal level. Available options include dual relays, analog output, serial communications, and low voltage power supply.
-
33430G Series(1800W / 3600W) -
PRODIGIT Electronics Co, Ltd.
Each 33430G Series has its own control and display panel, LED/CC/CR/CV/CP/ Dynamic modes, panel with 150 sets Store/Recall memory which provides load set-up more efficiently,also can be controlled intranet via RS232、Ethernet、USB and GPIB interface.
-
LAB / HPL -
ET System Electronic GmbH
*Output from 5kW to 10kW*Output voltage up to 600V*Output current up to 500A*Dimensions: 19 "x 3 U x 620mm*Integrated load; voltage controlled*For 2-quadrant operation*Compact design*Low noise development for pleasant work in the immediate vicinity of the device
-
Creative Design Engineering, Inc.
*Type: Floor Standing*Wafer load: FOUP LoadPort*Wafer size: 300mm, 8" and 300mmopen cassette with adapter*Mini Environment: yes*Probe Changer: 1,2 or 4 probes*Aligner: yes*Range: 1m/ to 10M/*Accuracy:0.5%*Repeatability: 0.02% *Static Repeatability: 0.1% dynamic
-
S94573B -
Keysight Technologies
The software enables power amplifier distortion measurements under varying load conditions that are controlled across the entire modulation bandwidth. When design verification and robustness evaluation require testing the device away from the optimum loading condition, this application provides powerful insight into device performance and degradation.
-
6034 -
Associated Equipment Corp.
• Carbon pile tester handles all 6/12 volt batteries• Two large 4.5″ analog meters display amps and volts• DC test leads are 2.5′ 4 AWG cable• Unit comes with manual adjust knob• Buzzer sounds after load is engaged for 15 seconds• Imported
-
Creative Design Engineering, Inc.
*Type: Table Top*Wafer load: open cassette*Wafer size: 4" to 8"*Mini Environment: N/A *Probe Changer: N/A *Aligner: N/A*Size: 12" x 28" x 10"*Range: 1m/ to 10M/*Accuracy: 0.5%*Repeatability: 0.02% *Static Repeatability: 0.1% dynamic
-
34300E Series(5KW~40KW) -
PRODIGIT Electronics Co, Ltd.
34300E Series has its own control and display panel, CC / CR / CV / CP / Dynamic modes, 150 sets Store / Recall memory which provides load set-up more efficiently, also can be remote controlled via GPIB、RS232、USB and LAN interface.SHORT time setting and SHORT_VH, SHORT_VL setting function, also can measure Short Voltage and Current.
-
36300E Series(50KW/60KW) -
PRODIGIT Electronics Co, Ltd.
36300E Series has its own control and display panel, CC / CR / CV / CP / Dynamic modes, 150 sets Store / Recall memory which provides load set-up more efficiently, also can be remote controlled via GPIB、RS232、USB and LAN interface.SHORT time setting and SHORT_VH, SHORT_VL setting function, also can measure Short Voltage and Current.
-
Hilkar
Line and load reactors are generally serial-connected to the input and/or output terminals of three phase equipment such as motor speed controllers, inverters and UPS systems. These equipment make use of semiconductor switches such as IGBTs, thyristors, and diodes and therefore create harmonic distortion and high switching over-voltages (dv/dt). Use of such equipment has been becoming more widespread as the technology advances. However, the negative effects of these equipment should not be overlooked.
-
Mantracourt Electronics Ltd
Mantracourt provide a range of signal converter modules which take load cell or strain bridge inputs and provide a data output in a variety of bus and protocol formats. Hardware formats include RS232, RS422 RS485, CAN and USB. Signal converter protocols include Industry Standards such as MODBUS, or Mantracourt’s own proprietary protocols which have been optimised for either ease of use (MantraASCII2) or higher speed communications (MantraBus2).
-
PLZ-5W/5WZ Series -
Kikusui Electronics Corp.
The PLZ-5W Series high performance electronic load is the successor to the highly respected PLZ-4W series, whilst still retaining the same high specification and build quality. Advances include a high visibility color display, low voltage operation from a minimum of 1 V to a maximum of 150 V. Programmable profiles of voltage/current can be applied (using the new ARB function, as used in LED/solar testing) in addition to the inherited 6 modes of operation: Constant Current, Constant Resistance, Constant Voltage, Constant Power, Constant Current + Constant Voltage, Constant Resistance + Constant Voltage.
-
62000D -
Chroma Systems Solutions, Inc.
Chroma 62000D programmable bidirectional DC power supplies have both power source and load characteristics, two quadrant operation, and allows feedback of the power from the DUT. They can be used for testing renewable energy power systems including PV/storage hybrid inverters, power conversion system (PCS) on charging/discharging, and as a battery simulator. The 62000D also is a fit for testing power components used in electric vehicles, such as bidirectional on-board chargers (BOBC), bidirectional DC convertors, and DC-AC motor drivers, and power conversion simulation tests of batteries in both directions.
-
LCD20 -
Mantracourt Electronics Ltd
Our intelligent strain gauge bridge amplifier is a compact, stackable microprocessor based unit specifically designed to control and monitor process applications. Flexible connection to most load cells, pressure or strain gauges over a wide range of sensitivities. The unit provides isolated current 4-20mA and voltage 0-10V analogue outputs and two digital inputs. Two set point relays can be configured to set thresholds such as net, gross, peak and valley. Powered from a wide ranging DC supply, the DIN rail amplifier is supplied with 2 part screw connectors for ease of installation.
-
IT8912E Series -
I-TECH Electronic Co., Ltd
IT8900 series high accuracy LED specific testing electronic loads can simulate the real output of LED lights with different characteristics.Their specific circuit can realize CR-LED mode, adjustable frequency, duty ratio PWM dimming output port (frequency: 20Hz-2KHz), I-pp/I-max measurement function can test current ripple and start up surge current of LED constant flow source. Voltage and current testing speed can reach 50KHz. IT8900 series provides CR-LED / CC / CV + CC / CR /CW and other working modes, built-in USB / RS232 / GPIB communication interface. Widely used in LED driver power dimming test.