Chroma Systems Solutions, Inc.

World recognized leader in power supply testing equipment which includes automated power supply test systems, electronic loads, programmable AC power supplies and related equipment to support the power conversion industry.

  • 949-600-6400
  • 949-600-6401
  • customercare@ChromaUSA.com
  • 19772 Pauling
    Foothill Ranch, CA 92610
    United States

Filter Results By:

Products

Applications

Showing recent results 1 - 15 of 57 products found.

  • Bidirectional DC Power Supply + Regenerative Load

    62000D - Chroma Systems Solutions, Inc.

    Chroma 62000D programmable bidirectional DC power supplies have both power source and load characteristics, two quadrant operation, and allows feedback of the power from the DUT. They can be used for testing renewable energy power systems including PV/storage hybrid inverters, power conversion system (PCS) on charging/discharging, and as a battery simulator. The 62000D also is a fit for testing power components used in electric vehicles, such as bidirectional on-board chargers (BOBC), bidirectional DC convertors, and DC-AC motor drivers, and power conversion simulation tests of batteries in both directions.

  • Benchtop DC Electronic Load

    63000 - Chroma Systems Solutions, Inc.

    Rated power: 250W, 350WVoltage range: 150VCurrent range: 60A max.CC, CR, CV & CP operation modesUser-defined waveforms (UDW)CZ mode for turn on capacitive load simulationReal time power supply load transient response simulationUser programmable 100 sequences viafront panelHigh precision voltage & current measurementVoltage, current & Pmax measurement for OCP/OLP testTiming & discharging measurement for batteriesShort circuit simulationSmart fan controlFull protection: OC (adjustable), OT, OP (adjustable) protection & OV warning, polarity reverse alarmStandard USB, optional Ethernet and GPIB interfaces

  • Modular DC Electronic Load

    63600 - Chroma Systems Solutions, Inc.

    Max. Power : 100W x 2(Dual), 300W, 400WVoltage Range : 80V, 150V, 600V5 module mainframe Max. 2000W, load modules up to 400W/eaUp to 10 channels in one mainframe, fit for testing multiple output SMPS0.4V @ 80A (Typical) low voltage operating characteristicsFlexible CC, CR, CV and CP operation modesCZ mode for turn on capacitive load simulation (up to 50,000uF capacitance emulation)Parallel mode for high current and power application up to 2kWMulti Channel synchronous controlReal time power supply load transient response simulation and Vpk+/- measurementUser programmable 100 sequential front panel input status for user-friendly operatingOver current protection (OCP) testing functionPrecision voltage and current measurementPrecision high speed digitizing measurement/ data captureVoltage, Current and Pmax measurement for OCP/OLP testingTiming measurement for batteriesShort circuit simulationSelf-test at power-onFull Protection : OC, OP, OT protection and OV alarmEthernet, USB and GPIB interfacesUser Defined Waveforms

  • Modular DC Electronic Load

    6310/A - Chroma Systems Solutions, Inc.

    Max Power: 200W, 100W2(Dual), 30W & 250W, 300W, 600W, 1200WWide range 0~500V operating voltageCompatibility between 6310 and 6310AUp to eight channels in one mainframe, for testing multiple output SMPSParallel load modules up to 1200W for high current and power applicationsSynchronization with multiple loadsFlexible CC, CR, CP and CV operation modesDynamic loading with speeds up to 20kHzFast response of 0.32mA/s ~ 10A/s slew rateMinimum input resistance allows the load to sink high current at low voltagesReal time power supply load transient response simulation and output measurementsUser programmable 100 sequences. Front panel input status for user-friendly operationHigh/Low limits of testing parameters to test GO/NGDigital I/O controlOver current protection (OCP) testing function16-bit precision voltage and current measurement with dual-rangeRemote sensing capabilityShort circuit testSelf-test at power-onFull Protection: OV, OC, OP, OT and reverse protectionUSB, GPIB & RS-232 interfaces

  • Low Power Programmable AC Source

    61600 Series - Chroma Systems Solutions, Inc.

    Power:500VA (61601)1000VA (61602)1500VA (61603)2000VA (61604)4000VA (61605)Voltage range: 0-150V/0-300V/AutoFrequency: 15Hz 1000HzCompact size and weight attributable to advance PWM technologyBuilt-in PFC, provide input power factor over 0.98 (full load)AC+DC output mode for voltage DC offset simulationProgrammable slew rate setting for changing voltage and frequencyProgrammable voltage, current limitOne-key recall for 9 different voltage and frequencyLow output impedance for testing IEC 61000-3-2 ( 61605 )Comprehensive measurement capability, V, Irms, Ipk, Inrush, P, Q, S, PF, CF of current and etc.High output current crest factor, ideal for inrush current testingTurn on, turn off phase angle controlTTL signal which indicates ON/OFFAnalog programming interface3 units combined to 3-phase power outputEasy-use software for operation and ON/OFF testOptional GPIB and RS-232C interfaceFull protection: OP,OC,OV and OT protection

  • 16 Channel Battery Cell Tester

    17216M - Chroma Systems Solutions, Inc.

    Chroma’s 17216M is a standalone 16 channel version of their 17011 series high precision charge/discharge tester specifically designed for Lithium-ion batteries, electrical double layer capacitors (EDLC), and lithium-ion capacitors (LIC). Suitable for product characteristics screening, cycle life testing, incoming and shipping inspection, material experiment, and balancing battery voltages.

  • Battery Test Systems

    Chroma Systems Solutions, Inc.

    These high precision, integrated battery test systems are designed for lithium ion and other chemistries and applications including EV batteries and energy storage systems. From R&D to battery production, Chroma’s battery test equipment provides advanced features including regenerative discharge systems that recycles energy from the battery back into the channels in the system or to the grid. Systems are configurable and flexible with multiple channel capabilities that can be upgraded as testing requirements change. In addition, the test system the finds charge rates, discharge rates, states of charge (SOC), states of health (SOH), and depths of discharge (DoD) with accurate measurements in voltage, current, temperature and power – statically and dynamically.

  • 100Hz-50kHz LCR Meter –

    11021/11021-L - Chroma Systems Solutions, Inc.

    The Chroma 11021/11021-L are the most cost-effective digital LCR Meters available, providing 100Hz, 120Hz, 1kHz, and 10kHz test frequencies for the 11021 and 1kHz, 10kHz, 40kHz, 50kHz test frequencies for the 11021-L. The standard RS232 interface, optional GPIB & Handler interfaces, high speed and stable measurement capabilities enable the Chroma 11021/11021-L for use in both component evaluation on the production line and fundamental impedance testing for bench-top applications.

  • 3-Phase Programmable AC Source

    61700 - Chroma Systems Solutions, Inc.

    Power: 1500VA, 3 (61701); 3000VA, 3 (61702); 4500VA, 3 (61703); 6000VA, 3 (61704); 12000VA, 3 (61705)Voltage: 0~150V/0~300VFrequency: 15~1.2KHzPhase angle: 0~360Built-in PFC, provides input power factor over 0.98Advanced PWM technology delivers high power density in a compact rack-mountable packageBuilt-in output isolation relaysAC+DC output modeProgrammable slew rate setting for changing voltage (optional function)Turn on, turn off phase angle controlUser-definable power-on statusPower line disturbance (PLD) simulation capability (optional function)Comprehensive measurement capability: V, Irms, Ipk, I inrush, P, PF, CF of current etc.Programmable r.m.s. current limitFull protection: OP, OC, OV and OT protectionGPIB and RS-232C interface (optional)Easy-use software for operation

  • AC / DC Electronic Loads – Benchtop Testing to Automated Test Systems

    Chroma Systems Solutions, Inc.

    Chroma is the global leader in Electronic Load manufacturing. Chroma’s AC Electronic Loads are designed for testing uninterruptible power supplies(UPS), Off-Grid Inverters, AC sources, and other power devices such as switches, circuit breakers, fuses and connectors. Chroma’s DC Electronic Loads are used for power testing in all markets including automatic test systems, LED, power supply testing, battery testing, and fuel cell testing. Chroma loads can do it all including full current down to 0.4VDC, CZ mode, user defined waveforms, timing measurements, and 3 current ranges per load. Chroma’s electronic loads come standard with either USB or RS232 ports for control and can be configured for GPIB (IEEE-488) control as well.

  • Impulse Winding Tester

    19301A - Chroma Systems Solutions, Inc.

    10V~1000V impulse voltage test, with 0.25V test resolutionHigh impulse test sampling rate (200MHz), 10bitsHigh/Low inductance test (0.1uH~100uH)Inductance contact check functionInductance differential voltage compensation functionBreakdown voltage analysis functionLow voltage range to increase the sensitivity of waveform analysis (32V/64V/128V/256V/512V/1024V)USB port for storing waveform & screen captureMulti-language, graphical color displayStandard LAN, USB, and RS232 interfaces

  • High Frequency LCR Meters up to 30MHz

    11050 - Chroma Systems Solutions, Inc.

    The Chroma 11050 Series HF LCR Meter is a precision test instrument designed to accurately measure and evaluate passive components at high speeds. Its measurement capabilities cover the primary and secondary parameters required for testing the inductance, capacitance, resistance, quality factor and loss factor of passive components. The HF LCR Meter has a broad testing frequency range 75kHz~30MHz/1kHz~10 MHz/60Hz~5MHz suitable for analyzing component characteristics under different frequencies. Its 0.1% basic measurement accuracy provides stable and highly reliable results. A fast 7ms measurement speed effectively increases productivity when working in an automated environment.

  • Chroma LCR Meters

    Chroma Systems Solutions, Inc.

    Some of the key features to look for in an LCR meter (also known as an impedance meter) are: accuracy, test frequency, measured parameters, test voltage and test current. Additionally, an easy to understand display of test results and the ability to access and use these results has become increasingly important. Component testing often requires much more than simply a resistance, capacitance or inductance value at a given test frequency and stimulus voltage. An LCR meter or impedance meter must have the flexibility to provide multi-parameters over wide frequency and voltage ranges.

  • 50Hz-100kHz LCR Meter

    11022/11025 - Chroma Systems Solutions, Inc.

    0.1% basic accuracyTransformer test parameters (11025), Turns Ratio, DCR, Mutual Inductance0Hz, 60Hz, 100Hz, 120Hz, 1kHz, 10kHz, 20kHz, 40kHz, 50kHz, 100kHz test frequencies21ms measurement time (≥100Hz)Agilent 4263B LCR Meter commands compatible4 different output resistance modes selectable for non-linear inductor and capacitor measuringHigh resolution in low impedance(0.01mΩ) and high accuracy 0.3% till 100mΩ rangeAdjustable DC bias current up to 200mA (constant 25Ω) (11025)1320 Bias Current Source directly control capability0.01mΩ ~ 99.99MΩ wide measurement range (4 1/2 digits)Dual frequency function (11022 option) for automatic productionBIAS comparator functionComparator function and 8/99 bin-sorting functionPass/fail judge result for automatic productionHandler interface trigger edge (rising/falling) programmableTest signal level monitor functionStandard RS-232, GPIB, and Handler I/FOpen/short zeroing, load correctionLabView® Driver

  • Battery Simulator Model

    A170202 - Chroma Systems Solutions, Inc.

    Multichannel battery packs state simulation.Follow the battery cell curve behavior to simulate battery state.Able to set frequently used parameters for battery pack and rapidly customize initial output state.Regenerative battery energy discharge function, power saving, environment-friendly and low heat output with 85% efficiency.Up to 60 channels can be paralleled for large current request.Operating mode: Constant Current/Constant Voltage/Constant Power discharge 600W, 1.25kW, 2.5kW, 5kW,10kW, 20kW, 30kW, 50kW, 60kW power per channel 20V, 60V, 100V, 200V and 500V voltage modules 2600A maximum current (paralleled)Dynamic current charge and discharge simulation.Highly accurate current and voltage measurement.Smooth and rapid current charge and discharge switching without interruption.Current smooth without surge when altering charge and discharge mode (CC-CV-CP).Independent channel protection function.