Filter Results By:

Products

Applications

Manufacturers

Showing results: 3991 - 4005 of 5298 items found.

  • Smoke Detection Sensor - UL Approved, TAA Compliant

    ENVIROMUX-SDS-TAA - Network Technologies Inc

    For warning of smoke. Photoelectric smoke detector. Built-in 135° F (57° C) thermal heat sensor. Includes mounting hardware. Connect to RJ45 or digital input sensor ports. Supports CAT5/5e/6 UTP or STP cables. Voltage Supply: 8-35VDC. Current Consumption: 200uA. Alarm Output: Relay (NO). Screw terminal. To connect to the RJ45 inputs use CAT5/5e/6 cable terminated at one end with RJ45 connector. Connect the un-terminated end to the sensor screw terminal. Maximum cable length: 1,000 ft (305 m). Powered by ENVIROMUX-2D/5D/16D. Regulatory approvals: UL. TAA compliant.

  • SparkFun Thermocouple Breakout

    MAX31855K - SparkFun Electronics

    The SparkFun MAX31855K Thermocouple Breakout is a simple 14-bit resolution, SPI-compatible, serial interface thermocouple digitizer that makes reading a wide range of temperatures possible. A thermocouple works by taking two wires made of dissimilar metals, connecting them at the two ends, and making a temperature gradient between one end and the other (a 'hot' end and a 'cold' one). Once this is achieved, a voltage potential is formed and current flows. The SparkFun Thermocouple Breakout takes a standard Type-K thermocouple in one end, digitizes the temperature measured and sends that data out the other end via a SPI interface, thereby interpreting the data and translating it for you to read!

  • Test Advisory Services

    TestingXperts

    The QA function has unique challenges in every enterprise, be it a small enterprise that is just at the beginning to set up a QA team or a multi-billion dollar giant with matured QA processes. The right QA strategy can help you improve the overall product quality, reduce release cycle time enabling faster time-to-market and controlling the rising QA costs. TestingXperts’ Test Advisory Services provides you the specialist advice to achieve these objectives and help you move to the next maturity level in QA. We deliver custom solutions that address your current business needs and align with your future aspirations.

  • Thin Film/Metal Film Chip SMD Chip Resistors

    Panasonic Industrial Devices Sales Company of America

    Panasonic’s industry leading Thin-Film Chip Resistors features include high reliability at high temperature and high humidity as well as high accuracy, low current noise and excellent linearity. Panasonic’s High Precision Thin Film Resistors are designed for robust applications where long life is crucial in markets such as automotive, appliance or industrial. These Resistors boast a high accuracy of up to 10ppm, 0.05% making them one of the best-in-class Resistors on the market today. Panasonic Thin-Film Resistors are available in case sizes down to 0201. Compliant standards include: IEC 60115-8, JIS C 5201-8, and EIAJ RC-2133B. These Resistors are AEC-Q200 Certified.

  • 150W Electronic Load

    EL63150B - MCH Instruments Co.,Ltd.

    Features:*Number operation and control*LED display with high definition and high contrast, rich display information*Easy operation of knob encoder switch*Basic load function: constant current, voltage, power and resistance*Multi units used to multiple load ability*Short-circuit test*Battery test*Dynamic test*Multi parameters measured in the list*Remote voltage measurement*Panel and exterior trigger function*Protection function: over-voltage, over-current, over-power, over-heat, polarity connection in reverse*10 sets of parameters memorized and loaded, and automatically loaded on turning on the instrument*Intelligent fan control*Key lock and knob lock functions

  • 300W Electronic Load

    EL3630B - MCH Instruments Co.,Ltd.

    Features:*Number operation and control*LED display with high definition and high contrast, rich display information*Easy operation of knob encoder switch*Basic load function: constant current, voltage, power and resistance*Multi units used to multiple load ability*Short-circuit test*Battery test*Dynamic test*Multi parameters measured in the list*Remote voltage measurement*Panel and exterior trigger function*Protection function: over-voltage, over-current, over-power, over-heat, polarity connection in reverse*10 sets of parameters memorized and loaded, and automatically loaded on turning on the instrument*Intelligent fan control*Key lock and knob lock functions

  • AC Clamp Meters

    CHY firemate Co., Ltd.

    Power measure of Active power (KW), Reactive power (KVAR),Apparent power (KVA), Power Factor (PF)PF (cosØ), for 3Ø4W, 3Ø3W, 1Ø2W, 1Ø3W.Triple display: KW+V+A easy to read.Recorded each wire parameters of V, A, KW, KVA, KVAR, PF, Hz,total 25 parameters.AC current up to 1000A, AC voltage up to 600V.INRUSH (100mS), HOLD and PEAK functions.MAX and MIN recorded functions.MAX. Cable size: Ø34mm.Auto power off (10 mins), Black-light.EN61010-1, 600V CAT IV, 1000V CAT III.Dimensions: 246mm (H) x 80mm (W) x 43mm(D).

  • Analyzers and Timers

    CAT Advanced Series - Amperis sl

    Description The Advanced CAT Series Analyzers and Timers are stand-alone or PC-controlled digital instruments for circuit breaker status evaluation. Timing channels record arc closing and opening, resistance and auxiliary contacts. The main contact channels can also measure the resistance value of pre-insertion resistors (if present in the breaker). The advanced CAT series records graphs of the opening and closing coil currents and the movements of the moving parts of the high and medium voltage circuit breaker. Test results are printed on the 112 mm (4.4 inch) thermal printer (optional accessory) in tabular and graphical form. The advanced CAT series provides easy selection of different operating modes:

  • Harmonics & Flicker Analyser

    AC2000A - Laplace Instruments Ltd.

    The Laplace Harmonics and Flicker analyser provides the user with a complete system for testing product compliance with IEC61000-3-2 and IEC61000-3-3. Quick and easy to use, the built-in screen provides a clear pass/fail indication of compliance status, plus a full listing of results for each harmonic, in either tabular of bargraph format. The instrument is properly configured to cope with fluctuating harmonics. The Flicker mode provides proper measurement of short term and long term parameters, using algorithms specified in IEC61000-4-15. In addition, inrush current measurements can be automated such that the product under test can be automatically cycled on/off with user entered time profiles.

  • Particulate Filter Management System

    PFS-ONE - HORIBA, Ltd.

    The highly precise weighing of emission particles has become increasingly important due to new legislative regulations such as Euro 6, WLTP, EPA 1066 or PM 10. PFS-ONE, the Particulate Filter Management System offers different weighing methods. This supports full compliance with current legislation in the automotive and environmental industry and also allows for flexibility of internal testing processes. The system covers the measurement, organization, tracking and control of particulate filter weighing. Built as a modular system, the PFS-ONE can be expanded from a stand-alone installation up to a fully integrated laboratory module and can be used for manual weighing or automated weighing via a robot.

  • Wind Direction Sensor

    ENVIROMUX-EWDS - Network Technologies Inc

    Balanced wind direction vane with a near-zero friction bearing and a high accuracy magnetic angle sensor to provide precision wind direction. Sensor range: full 360 degrees , zero deadband. Accuracy: ±1.8 degrees. Resolution: 12 bit or 0.025 degrees. Directional Vane approximately 8 inches (203 millimeters). 3 wire flying leads, 25-feet (7.6-meter). Supply voltage: 4.5 to 5.5 VDC. Current: 15 mA typical. Output: 5 to 95% of input voltage (0.25 to 4.75VDC). Requires the ENVIROMUX-S5VDC-5V to operate with ENVIROMUX-2D/5D/16D. Maximum cable length: 1000 ft (305m)

  • Thermal-Optical Analysis

    Elemental Analysis, Inc.

    As with other current organic carbon and elemental carbon (OC/EC) procedures, Thermal-Optical analysis is method-defined. However, this unit has been designed to specifically address some of the problems observed in other methods in assigning carbon to either the organic or the elemental fraction. By careful system control and continuous monitoring of the optical absorbance of the sample during analysis, this method is able to both prevent any undesired oxidation of original elemental carbon and make corrections for the inevitable generation of carbon char produced by the pyrolitic conversion of organics into elemental carbon. The OC/EC instrument utilized by EAC is used to analyze both bulk samples, and aerosol particles collected on quartz-fiber filters.

  • Camera Modules

    CameraModule - OtO Photonics Inc.

    Series is built with the linear back-thinned 2048 x 64 pixels CCD type sensor and high performance 32bits RISC controller in. CM series contains a Thermal Electric Cooler (TEC) along with cooling system design to reduce dark current and maintain a lower stable operating temperature. CM Series has outstanding sensitivity, high SNR ratio, high dynamic range, low electrical-heat noise and fast spectrum responds, suitable for 785 nm laser 2800 cm-1(790~1010nm) or 3500 cm-1(790~1090 nm) Raman application and long wavelength measurement (180~1100 nm).

  • IR Sensor

    JonDeTech

    The sensor measures a very useful 0.17 mm in thickness and is made of plastic. Essentially it is a piece of robust plastic that can be used “bare” – without protective housing, such as a metal casing commonly used by other producers. The sensor it is less than 0.2 mm. thin and it is made using plastic membrane. This configuration makes the sensor so robust it can be used “bare” – without protective housing such as a metal container. Due to the fact thatSince the sensor chip can be used applied bare, means it can be used in a totally new ways, which can re-defines todays the current view on application design and reduces the cost of the entire system, and not just the sensor-element as such.

  • USB-6525, 16-Channel, 60 V, 8 Solid-State Relays, 8 Inputs, Ch-to-Ch Isolated Digital I/O Device

    779640-01 - NI

    The USB-6525 is an industrial, bus-powered USB I/O device that can automate even the most demanding applications. The solid-state relay outputs are ideal for controlling pumps, valves, motors, and various other industrial actuators. The USB-6525 features channel-to-channel isolated digital inputs that you can use to read from industrial digital sensors, and eight solid-state relay outputs featuring 60 VDC/30 Vrms switching voltage and 500 mA per channel maximum switching current. Using programmable power-up states, you can configure the initial output states in software to ensure glitch-free, safe operations when connected to industrial actuators.

Get Help