DC502 -
Lisun Electronics Inc.
DC502 is CONSTANT CURRENT DC POWER SUPPLY for standard lamp. Function and technical indexes are as follows: • output voltage 4 grades: 6V/12V/24V/50V • output current: DC 0~2.5A (adjustable) • Output current drift at full scale: ±0.05% reading value/10 mins • Monitor range of ampere meter: 0.0000A ~1.9500A, 1.950 A ~2.500A • Accuracy of ampere meter: ± (0.08% reading value + 0.02% full scale) • Max output power: 80W • Continuous working time: 8 hours • Work environment: Temperature 0℃ -25℃, humidity ≤ 85%R.H, supply source: AC220 ±10%, 50/60HZ • Holding conditions: -20~50℃ humidity < 75%R.H • Outside dimension (W×H×D): 333mm×114mm×307mm • Weight: about 8kg • Power: about 1000VA
-
KT3201 -
Ketai instrument (kunshan) Ltd.
KT3201 KT3202 KT3203 KT3204 four high-precision multimeters are specially designed for European student watches.It has AC and DC voltage, DC current, resistance, capacitance, continuity, and diode measurement functions.Comply with safety standard CAT III 600V Fuse Φ6x31mm 600VKT3202 is a specially designed AC and DC voltmeter.KT3203 is a specially designed AC and DC ammeter .KT3204 is a specially designed DC low-current, low-voltage meter. The voltage can be measured from 0 to 100mV, and the current can be measured from 0 to 50uA.The pointer "0" is at the median value, and the voltage and current are divided into two sides.This set of four tables has certain practical significance for students' knowledge and understanding of Ohm's law in electrical engineering.This set of meters complies with the CAT III 600V standard.
-
Kyoritsu Electrical Instruments Works, Ltd.
Live circuit warning LED:Immediate illumination of a warning lamp if the circuit under test is live Auto Discharge:Allows fast and safe discharge of electrical energy stored in capacitive circuits following testing Integral overload protection on internal continuity and insulation test circuitry Autoranging 500V DC test voltage for insulation tests 200mA short circuit current on continuity ranges Loop and RCD Testing Wiring connection check LED''s:Immediate indication if wiring of circuit under test is correct Overheat Protection:Rapid detection of overheating of internal circuitry,display of warning signal to user and automatic halting of measurement Supply Voltage Indication:Can display supply voltage value in loop impedance mode Low Current Loop Impedance Test:Short duration low test current will prevent tripping of many passive RCDs
-
16502 -
Chroma Systems Solutions, Inc.
Basic accuracy : 0.05%Pulsed test current output mode is used to reduce thermal EMFs affection on milliohm measurementDC test current output mode is used to fasten measurement speed for inductive DUTDry-circuit test current output mode (limited Max. 20mV) is used to measure such contact resistances where the maximum open-circuit voltage must be limited to 50mVTemperature correction (TC function) regardless of material or temperatureUseful temperature conversion function for motor/ coil evaluation4 channels R scan with balance check function for fan motor (combined with A165017 option)0.001mΩ~1.9999MΩ wide measurement range with 4½ digits resolutionStandard RS-232 interfaceOptional GPIB & Handler interfaceBin-sorting functionComparator and pass/fail alarming beeper functionLarge LCD display (240 x 64 dot-matrix)Friendly user interface
-
2670A -
Shenzhen Chuangxin Instruments Co., Ltd.
0-5KV AC withstand voltage tester Features: High voltage,small current, high accuracy. Leakage current, testing time, continuous arbitrarily, well-adapted.
-
AF Series -
Com-Power Corporation
The AF series CDNs are for unshielded cables with two, four and eight conductors carrying low current. AF series CDNs are supplied 2 mm shrouded banana sockets
-
Renesas Electronics Corp.
Renesas' charging system safety circuits are optimized to provide a redundant safety protection to an Li-ion battery charging system by monitoring input voltage, battery voltage and charge current.
-
Renesas Electronics Corp.
Renesas' charging system safety circuits are optimized to provide a redundant safety protection to an Li-ion battery charging system by monitoring input voltage, battery voltage and charge current.
-
Tinsley Precision Instruments
The Delta series consist of clamp meters and clamp CT''s. This meter is basically used where the electric current in the conductor can be measured, without having to make physical contact with it.
-
HIOKI E.E. Corp
AC/DC Clamp True RMS 600/2000 A range V, A, Hz, , and other extensive measurement parameters Inrush current Max/Min/Avg/Peak Wireless data download to a tablet or smartphone
-
HEM Data Corp
The DAWN Mini ADAQ™ measures a variety of input types including voltage, current, temperature, digital, frequency, PWM, and inclination. It outputs measured data to a CAN network.
-
CPC Chassis Mount Series -
Semiconductor Circuits, Inc.
High performance DC-DC converters offer high efficiencies of 93% typical (12V model.) This high efficiency allows for minimal output current derating at elevated ambient temperatures.
-
Tinsley Precision Instruments
The Gamma series consists of digital multimeters. They are capable of measuring electrical parameters like current, voltage, frequency, temperature, resistance, diode test and continuity test of the circuit respectively.
-
Sanwa Electric Instrument Co., Ltd
Test tool used to measure two or more electrical values—principally voltage (volts), current (amps) and resistance (ohms). It is a standard diagnostic tool for technicians in the electrical/electronic industries.
-
041-970 -
ELMA Electronic, Inc.
The Hall-Sensor Board is the right accessory for your system in combination with the Elma SysMon. It's possible to measure up to 4 currents and to monitor them with the Elma SysMon 3 Gen.