product
Pocket Size Analog Multimeter
HH2708
Basic Accuracy 4.0%. 5 Functions / 14 Ranges. Voltage test up to AC500V and DC500V. Current test up to 250mA. Resistance test up to Ω x 1K. Test Batteries 1.5V and 9V. Power: 1 x 1.5V "AA" battery. Fuse: 0.5A, 250V type Φ 5 x 20mm
-
product
96 Pin 1.27mm Pitch Micro-D Connector & Cable Accessories
The 96 Pin 1.27mm Pitch Micro-D Connector is used on high-density PXI modules that require 1A current rating and voltage handling up to 150Vdc. If you would like to develop your own cabling solutions, we offer mating connectors and connector hoods that allow you to create either your own cable based solutions, or a PCB header solution. Connector Blocks directly terminate the module connector and convert the connection to arrays of screw terminal blocks, or you can select to use a remote DIN rail mounted breakout to terminate the cables at the end of a cable assembly. You can also try our Cable Design Tool to graphically design a customized cable assembly.
-
product
LXI Scalable Matrix - 2Amp Y1 To Y20 Plugin Module
65-219-102
This plug-in module is part of a scalable matrix platform designed to provide a large matrix solution with 2A current carrying capacity on all Y paths.
-
product
Ultra High 6.70 (190.00) - 11.80 (335.00) General Purpose Probe
EPA-4H-2
Current Rating (Amps): 7Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,320Overall Length (mm): 33.53
-
product
PXI/PXIe High Density 2A Multiplexer, 8-Bank, 8-Channel, 2-Pole
40-614D-004
The 40-614D-004 (PXI) and 42-614D-004 (PXIe) 8-bank, 8-channel, 2-pole multiplexers are part of the High Density 2A multiplexer module range available in 22 configurations (see 'Also in this Range' link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
product
AC Power Sources, Frequency Converter
MAC-01, -02, -03
For reliability, all models of the Titan AC Power Sources/Frequency Converters are fully current limit protected against either continuous or transient short circuit or overload conditions. When an overcurrent condition exists, the internal current control loop overrides the voltage control loop and scales back the sinewave drive until it sees a safe output current level.
-
product
Instrument Transformer
CT & PT Test Equipment
Measurements International Ltd.
Calibration of Voltage and Current Transformers from a Single Instrument, Calibration of Instrument Transformers with Different Rated Ratios Using One Single Reference Standard, Calibration of Voltage Transformers (VT) up to 800 kV When Used with MI 2500 Series of HV Dividers and Standard Capacitors, Calibration of Current Transformers (CT) Up to 10000 A When Used With MI 7020 and/or 7200 Series of Precision Current Transformers and/or Current Comparators, Test Frequency from 15 Hz to 100 Hz70.
-
product
Standard 1.00 (28.00) - 3.20 (91.00) General Purpose Probe
P2550-8
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,453Overall Length (mm): 36.91Rec. Mounting Hole Size (mil): 126Rec. Mounting Hole Size (mm): 3.20Recommended Drill Size: #30 or 3.20 mm
-
product
Battery Data Logging Device
FST-AM
Foresight Electronics Co., Ltd.
A data logger, is an electronic instrument that records measurements at set intervals over a period of time. Depending on the particular data logger, measurements can include: air temperature, relative humidity, AC/DC current and voltage, differential pressure, time-of-use (lights, motors, etc.), light intensity, water temperature, water level, dissolved oxygen, soil moisture, rainfall, wind speed and direction, leaf wetness, pulse signals, room occupancy, plug load, and many more.
-
product
PXI High Voltage Power Multiplexer, Twelve 2:1 (SPDT)
40-331A-006
The 40-331A-006 twelve 2:1 MUX is part of our range of 40-331A/332 High Voltage Power Multiplexer and Matrix Modules and is suitable for applications requiring high voltage power relay switching with high density. They feature current handling up to 5A, 1000VDC/1000VAC peak cold switching and 110VDC/250VAC hot switching.
-
product
Fixed Aperture RF Current Monitoring Probe
TBCP1-200
The TBCP1-200 is a fixed aperture RF current monitoring probe.The probe has a 3dB bandwidth of approximately 200 MHz. The aperture of the RF current monitoring probe is 25 mm. Its transfer impedance is > 14 dB Ohm in the range from 40 kHz to 200 MHz.
-
product
PXI/PXIe Battery Simulator Module, 2-Channel, V/I Readback, Simplified Current Sink, 750 V Isolation
43-752A-913
Targeting EV, automotive, aerospace, energy storage and electric aircraft applications, the new battery simulator modules occupy a single PXI slot. These 2-channel battery simulators are capable of supplying up to 7 V and 300 mA per channel. The channels are fully isolated from ground and from each other, allowing series connection to simulate batteries in a stacked architecture.
-
product
AC/DC Digital Clamp Tester (CE)
M-260
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Wide current measurements with tear drop type 55mmφCT up to 2000A.*Data-hold and Auto power off function.*Additional AC/DC voltage, resistance, diode test, continuity check.*Auto zero adjustment for DC current offset.*Conform to IEC safety requirements.
-
product
Network Analyzers
Contrel Elettronica s.r.l. Company
Complete monitoring of the plant. The network analyzers have been designed to combine maximum simplicity of operation with a wide choice of advanced functions. Measurements range from currents and voltages through energy consumption, harmonic components. Multifunction measuring instruments with basic energy quality analysis.
-
product
PXI-4072, 6½-Digit, ±300 V, Onboard 1.8 MS/s Isolated Digitizer, L and C Measurement Support, PXI Digital Multimeter
778270-01
6½-Digit, ±300 V, Onboard 1.8 MS/s Isolated Digitizer, L and C Measurement Support, PXI Digital Multimeter - The PXI‑4072 is a high-performance 6½‑digit, 300 V DMM that provides the measurement capabilities found in two common test instruments: a high-resolution DMM and a digitizer. As a DMM, the PXI‑4072 delivers fast, accurate AC/DC voltage, AC/DC current, 2‑ or 4‑wire resistance, frequency, period, and basic L and C measurements, as well as diode tests. In the high-voltage, isolated digitizer mode, the PXI‑4072 can acquire waveforms at sample rates up to 1.8
-
product
Super Megohmmeters | Electrometers | Picoammeters
Combine with specially designed power source unit PSU-8541 for high-speed measurement Resistance measurement Max. 310^16 Current measurement 0.1fA to 100A
-
product
Metal Foil Llow Resistance Chip Resistor
MFR (Metal foil)
*Low Resistance / TCR / EMF 9only FOR MnCu) / Inductance*Excellent long term stability*RoHS compliant and halogen free.*Lead free.* High precision current sensing and voltage division.
-
product
Standard CT
2000A
• High accuracy of 2000/5A (0.05%) • multiple ratios • Various Current ratings
-
product
Current logger0 to 20mA
TK-4802
Supplied with an input cable, this logger can measure current between 0 and 20mA DC and can be connected to many industry standard devices, such as CO2 sensors and current clamps, enabling the logging of a wide range of process parameters.
-
product
Elevated 1.68 (48.00) - 7.00 (198.00) High Performance Lead Free Probe
LFRE-1I-7
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Counter Electrodes
For a system using a three-electrode potentiostat, we measured current when a potential is applied between the working electrode and the reference electrode. Passage of current through an electrical circuit requires electron transfer reaction between the working electrode and the counter electrode.The main function of the counter electrode is to provide the location of the second electron transfer reaction. Important parameter of the counter electrode is the surface area. It is required (area) l...show more -
product
High Accuracy Digital Puncture Tester
KT-5000Pi
This product improves the absurdity that the existing Puncture Tester has many errors between the indicated voltage on its meter and the real output voltage, and also that one cannot check how much current flows during test, and then attaches a voltage meter and a current meter. Its accuracy is high due to Digital method adopting a three point adjustment type. Also, for user's convenience and for making easy to connect with automation line, many input, output functions are added. Now, Puncture Tester also should be accurate and a high-grade product
-
product
3-5 Watt Power Amplifiers
CCM1095 and CCM2096
The CCM1095 and CCM2096 are power amplifiers that use current efficient Silicon Carbide output semi-conductors to achieve +35 to +38 dBm output power. An internal sequencing circuit is included to provide for safe operation of the output power device.
-
product
High Power Digital Lab Series Regulated DC Power Supply – 3000W
- 3000W different combination- High current density.- 19″ rack adaptable -5U high- Remote sensing.- Front panel potentiometer to set V&I- 3Digit seven segment display for V&I- High stability and close regulation- Phase controlled preregulation plus linear post regulation Optional, at extra cost- Over voltage protection- 19″ rack mounting
-
product
PXI/PXIe Battery Simulator Module, 2-Channel, Simplified Current Sink, 750 V Isolation
43-752A-903
Targeting EV, automotive, aerospace, energy storage and electric aircraft applications, the new battery simulator modules occupy a single PXI slot. These 2-channel battery simulators are capable of supplying up to 7 V and 300 mA per channel. The channels are fully isolated from ground and from each other, allowing series connection to simulate batteries in a stacked architecture.
-
product
Open Loop Hall Effect Current Sensors Transducers With Rectangle Windows
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on open loop principle and designed with a highgalvanic isolation between primary conductor and secondary circuit. It can be used formeasurement of DC current, DC pulse currents etc. The output of the transducer reflects thereal wave of the current carrying conductor.
-
product
High Voltage Probes To Measure Primary Waveforms With A Power Analyzer
Volt Litewire
The Litewire is a true RMS meter designed for use by electric utilities to sense currents or voltage waveforms from the primary side of their distribution networks.
-
product
Professional Multimeter
Shenzhen UYIGAO Electronic Technology Co., Ltd
*This MultiMeter is a handheld digital multimeter, high reliability and portability, a perfect tool for the laboratory, factory and home.*It can measure AC/DC voltage, AC/DC current, resistance, capacitance, frequency, duty cycle, diode, continuity, NCV and temperature.*Moreover, more advantages such as backlight, data hold, auto range, true RMS, auto power off, low battery indication and over range indication.
-
product
Primary Injection Test Systems
Weshine Electric Manufacturing Co., Ltd
1.DC display primary current, secondary current test value, easy to observe and record the experiment..2.High measuring accuracy: 0.5 level.3.Small size light weight easy to carry.
-
product
PXI 48 x SPDT Power Relay Module
45-157-001
The 45-157 SPDT Power Relay Module consists of 48 single pole changeover relays controlled by a PXI/CompactPCI interface. It is suitable for applications were conventional reed-relay based switching modules do not have sufficient voltage rating or current carrying capacity. All 48 contacts are electrically isolated from each other and are capable of switching resistive and inductive loads up to 2000VA at 240V AC.