Filter Results By:

Products

Applications

Manufacturers

Showing results: 3571 - 3585 of 5298 items found.

  • Turns Ratio Meter

    Model TRM200 - Gopal Electronics

    Turns Ratio Meter Model TRM200 is widely used in transformer industry in manufacturing and repairing service. It directly display the ratio of LT turns & HT turns. It is capable to measure turns ratio till 1:1200. Turns ratio meter is designed to be a rugged and reliable. It is equipped with stable 250mA source. The design is based upon in-house invented & patented technology. TRM200 has also option for 1amp current source on demand.

  • X1 Pro DC/DC Multi-Charger

    44215 - Hitec RCD USA

    Our X1 Pro DC/DC battery charger delivers a powerful 180 watts to your Lithium-based, NiCd, NiMH and Lead-Acid batteries. With an adjustable charge current rate of 0.1~16 amps, this single port powerhouse provides exactly what your hobby demands in the workshop, at the field or in the pits. The X1 Pro design includes docking capability with our ePowerBox 17A power supply upping its ante in convenience and portability.

  • DC Power Analyzers

    Keysight Technologies

    DC Power Analyzer provides unrivaled productivity gains when sourcing and measuring DC voltage and current into a DUT. The Keysight N6705C DC Power Analyzer is a highly integrated instrument that combines up to four advanced DC power supplies, DMM, oscilloscope, arbitrary waveform generator and datalogger. It provides an easy-to-use interface, with all sourcing and measuring functions available from the front panel. The N6705C makes these tasks easy:

  • PXI Digital to Analog Converters

    Keysight Technologies

    Keysight's PXI digital to analog converters and V/I sources are capable of supplying high and low voltages levels as well as source currents on one or multiple channels.

  • Multiphase Power Analyzer

    2800 Series - Valhalla Scientific Inc.

    The Valhalla Scientific 2800 High-Precision Power Analyzer is available in 1-, 2-, 3-, 4-, 5-, or 6-phase versions.  All voltage inputs 0.3V up to 1500V peak and all current inputs 1.5mA up to 1A; 15mA up to 5A; 1A up to 40A; and shunt inputs 60mV up to 6V are potentially free and exhibit low noise, high common mode suppression, excellent DC-stability, wide frequency range (DC-2MHz) and very low self-heating on current inputs.There is no need to fiddle with DC-compensation, or changing current plugging.  All is built into the input sections of the power analyzer, ready for measurements.  It is simple to use, your intuition will guide you to operate the Power Analyzer touch screen correctly.

  • Circuit Breaker Identifiers

    188 FFF - Standard Electric Works Co., Ltd

    ● The 188FFF doesn't have the function of the sensitivity adjustment. If the customers need the sensitivity adjustment function, plase refer to other models.● The 188FFF is a Fuse and Fault Finder which comprises of two parts : The Receiver and the Transmitter.● The Transmitter, draws a current from the mains supply circuit to which it is connected to. The Signal● Current from the Tx is at about 10kHz. The Transmitter is powered by the mains and requires no batteries.● The 10kHz signal current generated by the Transmitter is then searched(sniffed) by the Receiver to detect the Fuse, Circuit Breaker or the faulty circuit.● The Receiver is a tuned circuit which has it's center frequency tuned to about 10kHz. The sensor is located in the tip of the Receiver.● The amplitude of the received signal is shown on a bar-graph type Leds.● The more Leds ON, the stronger the signal.

  • Cable & Insulation Testers

    Greenlee Tools

    A cable insulation resistance test is a test that is performed by applying 500 V or more between the conductor and ground and measuring the resulting leakage current. An insulation resistance tester is a test instrument that measures current that leaks through the insulation into ground. Insulation resistance tests can be performed with insulation multi- meters (IMMs) or megohmmeters. Insulation resistance testers are calibrated to display megohms (MΩ) of resistance. A satisfactory insulation resistance measurement should be in millions of ohms.

  • Supercapacitor Test

    Landt Instruments, Inc

    The CT3001A/C battery test systems are upgraded from CT2001A/C with higher precision and data logging rate. The tester can be used to run precision tests for coin cells, pouch cells, prismatic cells, and especially supercapacitors (ultra-capacitors). Each tester has 8 independent channel which can be programmed to run constant current charge/discharge, constant voltage charge, constant power discharge, constant resistant discharge, and direct current internal resistance (DCIR) tests.

  • High-Voltage Power Amplifier

    Model 40/15 - TREK, INC.

    The Model 40/15 is a DC-stable, high-voltage power amplifier featuring an all solid-state design for high slewrate, wide bandwidth, and low-noise operation. It is configured as noninverting with a fixed gain of 4000 V/V and is protected against overvoltage and overcurrent conditions that may be generated by active loads or by output short circuits to ground. Precision voltage and current monitors provide low-voltage representations of the high-voltage output and load current for monitoring purposes or for use as feedback signals in a closed-loop system.

  • FTL Test Block

    SecuControl inc.

    FTL testblock with dust cover and current disconnect pinThe FTL is a test block for interfacing substation devices (protection relays, fault recorders, revenue meters, ... ) to the voltage and current transformers and to other equipment on the system side of a power grid. The FTL test block uses disconnect pins to isolate the substation devices from the system side equipment. Once isolated, secondary injection can be performed using banana jacks on the front side of the test block.

  • Insulation & Multifunction Tester (LCD Display)

    4167 MF - Standard Electric Works Co., Ltd

    ● High Quality Taut Band movement.● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● Test test leads are supplied as standard accessories for simplified two-wire measuring system.● Two insulation test voltages(DC) : 250V and 500V.● Alternation voltage measurement.● Battery life indicator.● Fuse protected.

  • 3 Wire (Digital) Earth Resistance Tester

    1620 ER - Standard Electric Works Co., Ltd

    ● Microprocessor-controlled.● Measures earth resistance in three ranges : 40Ω, 400Ω, 4kΩ.● Capable of measuring earth voltage.● 3 ¾ digit (4000 counts).● LCD backlight display.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● Data hold function.● Relative function.● Auto power-off function.● Low battery indication.● Calibration performed with supplied test leads.

  • Multi-purpose Tester

    DEL-101 - Standard Electric Works Co., Ltd

    ● Mains wiring polarity check.● ELCB/RCD testing.● Measuring ear for line current.● Measuring ear for leakage current.● Helps calculate insulation resistance.● Helps calculate power consumption.● Helps fault finding of standing earth fault.● Fused main adapter.● Appliance testing (with the aid of a clamp meter).● Fused appliance socket.● No batteries required.● HRC fuse inside.● Fused, color-coded universal test sockets.● Universal mains IEC Lead.

  • Relay Protection Test Cabinet

    SFJ018 - Shanghai Launch Electric Co., Ltd.

    SFJ018 relay protection test cabinet uses double carbon brushes regulator, big buttons for regulating AC/DC voltage, current under large loading, small buttons for regulating AC/DC voltage, current under small loading,. The two output channels could work simultaneously. It also take use of digital meters of Grade 0.5, sensor of high accuracy, six digital display stop watch, satisfying requirements for time measurement.

  • Compact Digital Multimeter

    PDMT08 - Pyle Audio Inc.

    Double-Molded Plastic HousingHigh-Contrast LCD DisplayCATIII RatedVoltage DC: Max Range 600 V, Accuracy: +/- 0.5%Voltage AC: Max Range 600 V, Accuracy: +/- 1.2%Current DC: Max Range 10 A, Accuracy: +/- 2.5%Resistance: 2 M, Accuracy: 0.8%Diode CheckContinuity TestAccessories Included: Test Leads, 9V BatteryDimensions: 5.91' H x 2.76' W x 1.89' DWeight: 8.99 oz.Sold as : Unit

Get Help