  • Fast Digital Integrator

    FDI2056 - Metrolab Technology SA

    The Fast Digital Integrator FDI2056 is the world's fastest and most sensitive voltage integrator. Simply plug in a sense coil and measure fast, low-level magnetic field disturbances such as eddy currents in a switched magnet.Equipped with a high-speed Analog-to-Digital Converter (ADC), high-resolution clock, and highly optimized digital integrator, the FDI2056 boasts a maximum of 500 000 partial integrals per second and provides resolutions down to 10-14 Vs with an accuracy of 10 ppm. Magnetometer Fluxmeter

  • GPIB to Parallel Printer Interface

    Model 4892B - ICS Electronics

    * Adds a GPIB Interface to Printers with Centronics or IEEE-1284 parallel interfaces. See the compatible printer list. * Replaces obsolete printers and plotters with a current HPGL/PCL5 printer.* Prints and Plots from most Analyzers. * Large 256 kbyte buffer and high speed GPIB interface off-loads the instrument and reduces printing time.* No program changes required.* Rack mountable in 1 U high rack mount kit.* Includes universal VAC Power Adapter and printer cable.

  • High Voltage Linear Power Supplies Bipolar 4-quadrant, Analog/Digital/Local Control, Ultra Low Ripple/Noise

    Series BOP-HV - Kepco, Inc.

    The Kepco Model BOP 500DM and BOP 1000DM are high voltage power sources, up to 500V or 1000V, respectively. These combine the capabilities of fast programmable power supplies with a Class A output stage, which can respond bidirectionally from zero. The BOP-HV can be operated in either a "voltage stabilizing" or "current stabilizing" operating mode (selectable by a front panel switch). These power supplies offer ultra low noise and ultra low ripple at the output and are MIL-STD-461 compliant.

  • Isolated ADCs

    STMicroelectronics

    Isolated analog-to-digital converters (ADCs) are second-order sigma-delta modulators that convert analog values into a 1-bit stream and are able to withstand high common-mode voltages.Combining a high-frequency external clock input and wide bandwidth, our isolated ADCs provide very high accuracy thanks to the improved signal-to-noise ratio (SNR). The isolation grade and a high level of transient immunity are keys to reliably sensing currents and voltages to ensure the robustness and high performance of many industrial applications.

  • Motor Driver ICs

    STMicroelectronics

    The ST product portfolio offers a wide range of motor control ICs, well-suited for the most demanding automotive environments, covering the requirements of brushed DC motors, stepper motors and brushless DC motors, over an extensive range of voltage and current ratings. Efficiency and accuracy of our motor drivers are guaranteed by a unique combination of low-loss PowerMOS output stages and advanced control circuitry. Robustness and reliability are provided by the integration of a comprehensive set of protection and diagnostic features.

  • Potentiostat Galvanostat

    EchemLab XM - Ametek Scientific Instruments

    EchemLab XM includes a reference grade potentiostat and frequency response analyzer (FRA). EchemLab XM has a built-in 100 V high voltage amplifier which can be used for not only for compliance measurements but also for high voltage cell polarization. This is useful in many high solution resistance applications, for example in organic electrochemistry. In addition to high voltage, power boosters can also be integrated to combine high current and high voltage in many specialized plating applications.

  • Power Amplifiers

    Cleverscope Ltd.

    Power Amplifier is used to amplify the output of the CS700A or CS701 signal generators. The 52 MHz bandwidth amplifier can swing 36Vpp with an output current up to 1A continuous. The CS1070 includes an internal inverting power supply to provide the negative rail, simplifying power supply requirements. The gain is fixed at x10 (20dB). The output voltage range is ±5V to ±18V and asymmetrical to +31, -5V for PSRR measurements right up to 30V as the input supply increases past 20V.

  • Power Monitors

    Analog Devices Inc.

    Analog Devices’ power monitoring amplifiers provide an integrated solution for digital current and voltage measurement via an on-chip, 12-bit analog-to-digital converter (ADC), communicated through an I2C interface. Leveraging ADI’s precision analog design techniques, ADI’s products are twice as precise as competing devices, offering best-in-class accuracy (<±0.8%). The power monitors complete the industry’s only monitor and sequencer family to deliver <±1% accuracy for 2 to 12 supplies.

  • Power Quality Analyzer

    PQPro - CANDURA Instruments

    The PQPro™ is a portable 8 channel (4 voltage and 4 current) power quality analyzer that can stream high resolution waveform and RMS data to high capacity removable SD memory cards. Sampling rate can be adjusted from 64 samples per cycle to 1024 samples per cycle. The PQPro™ is in a rugged weatherproof enclosure that can be left recording in all kinds of environments - from the top of a utility pole to the bottom of an underground mine shaft!

  • Pulse Magnetic Field Generator

    SKS-0902 - Shanghai Sanki Electronic Industries Co., Ltd.

    The technical parameters of the pulsed magnetic field generator SKS-0902 fully comply with the new standards of IEC61000-4-9 and GB/T17626.9; the pulse current output of up to 2000A can meet the needs of different user groups; it adopts a self-developed CNC high-voltage power supply, High precision, high stability, long service life; using self-developed high-voltage electronic switch as the main switch, high stability, smooth output waveform; achieving 0°~359° synchronous phase triggering.

  • Temperature Controllers

    WIKA Alexander Wiegand SE & Co. KG

    The compact temperature controllers from WIKA offer display, control and monitoring of temperatures. The configuration of the sensor input is made via the multi-function input. Resistance thermometers, thermocouples and standard industrial signals, such as 4 ... 20 mA, serve as the input variable of a temperature controller. The monitoring output can be set either as relay (for slow control), as logic level for the control of electronic solid-state relays (for fast control and high current loads) or as a continuous 4 ... 20 mA output.

  • Thermocouple Temperature Data Logger

    TCTemp2000 - MadgeTech, Inc

    The TCTemp2000 is a thermocouple temperature data logger perfect for applications requiring instant remote readings of temperature. The 8-button keypad and large LCD provide convenient access to current data and data logger setup. This data logger has an internal temperature sensor and one external input for J, K, T, E, R, S, B and N type thermocouples. Additionally, memory and battery levels, external power status, sampling and recording status are shown on the LCD.

  • Signal Relays

    Panasonic Industrial Devices Sales Company of America

    Mechanical Relay ideal for signal control, etc., with less than 2A nominal switching capacity. Low Level current switching below 2A. Features include gold contacts, stable contact resistance, fully sealed construction, Form C contact arrangement, available latching and low operating power, and compact size for optimal board space usage. Applications include: AC Control, Communications, Security, Measurement Equipment, Audio Visual Devices, and Automotive.

  • Thermalyze Extension for Steady State Analysis

    Lock-In - OptoTherm, Inc.

    Steady-state thermography is limited to detecting hot spots that heat up a minimum of 100 mK (0.100°C). This may be useful for locating shorts on high-power devices, but is inadequate for detecting low power defects such as semiconductor device leakage current or short circuit with very low or very high resistance. Steady-state thermography also suffers from poor spatial resolution as the heat from localized hot spots diffuses rapidly, blurring the location of the heat source.

  • Magnetic Core Selector

    UI9702 - Lisun Electronics Inc.

    • Measure relative value of μm, Bs, Br, Hc integrated factor• No need of wiring, direct testing, being convenient• Automatic selecting, out of limit alarming, freely setting of the selecting limit• Driving current for test: 0-2A, frequency for test: 20-50kHz, both continuously adjustable, Comply with actual working situation of electronic ballast• No need of adjusting the instrument every day• Digital display, easy to read, simply and quickly to operate• Print B-H curve