Showing results: 4726 - 4740 of 5298 items found.
-
Shanghai MCP Corp
Store characteristic curves and panel setting parameters. Programmable test conditions ,measured results PC stored. Three cursor measurement modes: point, line, window. Two cluster characteristic curves display simultaneouslyfor compare and pairing. Screen read outβ, gm, Vce, Ic, breakdown voltage, leakage current and other parameters . Repeat and single measurement. Self-checking function . 7 Inch high-resolution TFT color LCD. Standard interface: USB, RS232, LAN
-
Silicon Labs
Silicon Labs' innovative digital isolation and power product portfolio includes CMOS digital isolators, isolated gate drivers, isolated current sensors, isolated system products and Power over Ethernet (PoE) families. These mixed-signal IC solutions leverage Silicon Labs' superior isolation and high voltage expertise to enhance power system performance, flexibility and reliability while reducing system size and cost. The entire isolation portfolio supports isolation voltages up to 5 kV.
-
Analog Devices Inc.
Analog Devices translinear logarithmic amplifiers utilize advanced translinear techniques to provide an exceptionally large dynamic range in a versatile and easily used form. Our portfolio relies on proprietary innovations in design and precision laser trimming to achieve the wide measurement range and accuracy in products such as the AD8304 and AD8305. ADI translinear logarithmic amps are used in a variety of applications including optical power measurement, wide range baseband logarithmic compression, the measurement of current and voltage ratios, and optical absorbance measurements.
-
ATG 2 -
BAUR Prüf- und Messtechnik GmbH
Cable fault location with the BAUR ATG 2. The ATG 2 burn down transformer is used for impedance reduction of cable faults in low- and medium-voltage networks. The short-circuit proof 2300 VA stray field transformer delivers a maximum voltage of 10 kV and is housed in a fully enclosed 19" housing.* Portable device for changing the fault resistance* Useful for cables that are difficult to access* Proven methods for complicated faults* Independent current and voltage control on each burning level
-
ATG 6000 -
BAUR Prüf- und Messtechnik GmbH
Cable fault location with the BAUR ATG 6000. The high performance ATG 6000 burn down transformer is used for impedance reduction of cable faults in low- and medium-voltage networks. The short-circuit proof 5.75 kVA stray field transformer delivers a maximum voltage of 15 kV and is housed in a fully enclosed 19" housing.* Proven methodes for cable faults that are difficult to locate* Useful for cables that are difficult to access* Robust construction for reliable functions* Independent current and voltage control on each burning level
-
CLAMPMETER,OPEN JAW (CSJ-100) -
Greenlee Tools
*AC amperage, AC/DC voltage measurement*Open jaw design eases AC current measurement*Slim profile with build-inprobe storage on back*Measures resistance up to 20MΩ*Audible continuity and diode test*Bright LED and audible alarm for non-contact voltage detection*Auto power off for longer battery life*Data hold to capture measurements*2000 count LCD*Accessories included: (2)1.5V AAA batteries, test leads and carrying case*Lifetime Limited Warranty
-
7128A -
Peaceful Thriving Enterprise Co Ltd
This is a auto-ranging, high accuracy and stable hand held clamp meter to make electrical maintenance safe and easy. With special designed IC to support true RMS, the meter is available to measure AC/DC voltage to 600V, AC current to 200A and resistance to 20MΩ; also having the capability to test diode, continuity and non contact voltage sensing. Sub switch included Function Select, Max-Min Indication, Value Hold, Range Select, Relative Value Measurement, Illumination and Back-light.
-
BMS-3923 -
Kongter Test & Measurement Co., Limited
This battery monitoring system is an innovative solution to measure battery condition with communication way of Power Line Carrier (PLC). With multi-frequency measurement, users can monitor and analyze battery in all aspects: internal resistance, voltage, current, capacitance, temperature and so on.Based on our years experience for battery management system, we build very mature mathematical model that precisely predicts battery capacity. This will in another hand reduce the time that we spend on capacity measurement using a battery load bank.
-
BDS-Pro -
Eagle Eye Power Solutions
Eagle Eye's BDS-Pro Battery Monitoring System is designed to measure the aging status of up to 24 jars (or 24 cells) by measuring and recording: string voltage and current, as well as jar/cell voltage, internal resistance, connection resistance and temperature. The BDS-Pro Battery Monitoring Solution is the most accurate, user-friendly and economic solution for monitoring 24 jars (or 24 cells) systems using 1.0-16V batteries. Although the BDS-Pro is utilized in many industries, it is most frequently used in 24 cell, 48Vdc applications.
-
Foresight Electronics Co., Ltd.
Utility is used for battery systems range from 21-30V, if higher current is needed, two or more FST-24V units can be linked together. Discharge to Battery string voltage as 24V, Cell voltage as 1.2V/2V/6V/12V adjustable stop points and multiple alarm designs to control the discharge process intelligently 7inch LCD touch screen for easy operation and showing various parameters real time Support RS232 real time monitoring by PC or SD Card download data after discharge
-
EMS-PT30C -
Progressive Industries
Progressive Industries Portable Electrical Management Systems (EMS) offer quick and easy RV electrical protection. A true plug-and-play application with no installation required. You will feel secure with multi-mode surge, voltage, polarity, and lost/open neutral protection. Each unit includes a digital display, scrolling continuously through the power source information: voltage(s), current frequency, error code, and previous error code (if applicable). Additionally, the computer is driven by state of the art microprocessors.
-
EMS-PT50C -
Progressive Industries
Progressive Industries Portable Electrical Management Systems (EMS) offer quick and easy RV electrical protection. A true plug-and-play application with no installation required. You will feel secure with multi-mode surge, voltage, polarity, and lost/open neutral protection. Each unit includes a digital display, scrolling continuously through the power source information: voltage(s), current frequency, error code, and previous error code (if applicable). Additionally, the computer is driven by state of the art microprocessors.
-
American Probe & Technologies, Inc.
This new series of software allows you to analyze materials or semiconductor leakage with all of the capabilities of your HP 4140B to resolutions of 1 fA @ 100VDC. Completely rewritten in Visual Basic for Windows XP operating system, it offers Virtual Front Panel Operation of 4140B for I-V & CV Analysis and allows operator to virtually control the 4140B for any instrument operation. I-V Plots with options of displaying current over time. CV Plots with high resolution plotting capability.
-
USB-2401 -
ADLINK Technology Inc.
The USB-2401 is a 24-bit, 4-channel simultaneous-sampling universal input USB DAQ modules featuring built-in signal conditioning circuitry, providing direct measurement of commonly used sensors including current output transducers, thermocouple, RTD, load cell, strain gauge, and others. Individual channels can be programmed to measure different signal types. The USB-powered USB-2401 is equipped with removable screw-down terminals for easy device connectivity, and the included multi-functional stand fully supports desktop, rail, or wall mounting.
-
PP1S -
Hsiang Cheng Electric Corp
1. Measuring and conversion IEC 6882. Dielectrical strength IEC 688 4 KVac / 1 min.3. Impulse test ANSI C37.90 / 1989 IEC 255-3 5KV ( 1.2 x 50 us ) 3KA ( 8 x 20 us ) - current coil4. Surge test (ring wave) ANSI C37.90 / 1989 ( 3KV - 0.5us / 100KHz ) IEC 255-3 ( 2.5KV - 0.25ms / 1MHz )5. Adaptability for power system VDE 0110 6. Measuring reliability VDE 3540