Filter Results By:

Products

Applications

Manufacturers

Showing results: 1276 - 1290 of 5298 items found.

  • Secondary Injection Relay Test Set

    TD 1000 PLUS - Altanova Group

    TD1000+ is a protective relay test set especially designed to give the commissioning engineers a multitasking and highly reliable testing equipment. In comparison with T 1000 PLUS model, TD 1000 PLUS has two current outputs to test the differential relay characteristic curve, besides the pick-up current.

  • Digital DC Nano Ammeter

    PGP Electronics Private Limited

    PGP Electronics Digital DC nano Ammeter is a very versatile and general purpose equipment for the measurement of low DC current. It is a precision tool which provides a resolution of 100pA. This instrument finds application in all the electronic, electrical or physics laboratories wherever there is a need to measure the lower current range.

  • ABex Terminal Module for Extending the Functionality of the PXI-501

    ABex TM-501 MFI - Konrad Technologies GmbH

    The ABex TM-501 is an ABex terminal module that extends the multifunction measurement card PXI-501 with additional features. It is located in front of the PXI-501 card.It expands the analog outputs voltage range of the PMUs to -10V up to +40V. Additionally it features a shunt current measurement unit to measure currents up to 500mA

  • CT Burden Tester

    585 - Radian Research, Inc.

    The 585 Burden Tester is a hand held unit rated for use up to 20A. The design features a digital LED meter for displaying the current transformer (CT) secondary current. The burden is applied for a specific length of time controlled by circuitry inside the unit to help prevent the burnout of the burden elements.

  • PXI Dual 3-Channel 10A Solid State MUX

    40-666-011 - Pickering Interfaces Ltd.

    The 40-666 is a high current multiplexer available in dual 3-channel or single 6-channel configurations occupying two slots of PXI chassis. Each multiplexer switch uses a fully isolated solid state relay which has been designed to offer fast operation under hot switching conditions and high inrush current with no operational life degradation. Each multiplexer channel can support 10A of continuous current and switch up to 200V signals. The switches can sustain inrush currents in excess of 50A. AC or DC signals can be switched since the switch is polarity insensitive. Note: The 40-666-011 supersedes the 40-666-001 which is functionally the same but with some changes in specification. A data sheet for the 40-666-001 can be found in the40-666/667 User Manual.

  • PXI Dual 3-Channel 30A Solid State MUX

    40-667-011 - Pickering Interfaces Ltd.

    The 40-667 is a high current multiplexer available in dual 3-channel or single 6-channel configurations occupying two slots of PXI chassis. Each multiplexer switch uses a fully isolated solid state relay which has been designed to offer fast operation under hot switching conditions and high inrush current with no operational life degradation.Each multiplexer channel can support 30A of continuous current and switch up to 40V signals. The switches can sustain inrush currents in excess of 120A. AC or DC signals can be switched since the switch is polarity insensitive.Note: The 40-666-011 supersedes the 40-666-001 which is functionally the same but with some changes in specification. A data sheet for the 40-666-001 can be found in the 40-666/667 User Manual.

  • Resistivity Meter with Multi Electrode

    POLARES - PASI srl

    Till this moment the use of Electrical Resistivity Tomography (ERT) for geology has always been basically the same since its debut, based on the original vertical Electrical Soundings (VES) principles: applying a continuous current to two stakes inserted into the ground and measuring the corresponding voltage between other two. The applied current and thus the relative tension have always been continuous, with an inversion in polarity for each measure. The new tool POLARES uses an alternate current, instead, sinusoidal type, with an adjustable frequency.

  • Photonic Hall Effect

    HMS7000 - ECOPIA

    Classic hall effect measurement system is to read voltage difference made between both diagonal sides, when flowing current and applying magnet field strength, in perpendicular to flowing current direction. - Photonic hall effect measurement is to read various electrical properties by illuminating light of “various range of wavelength” on the sample, in addition to flowing current and applying magnet field strength. - It is great to see “RGB (Red, Green, Blue), Light intensity vs carrier density, carrier mobility, resistivity, hall coefficient”

  • Ocean Surveyor

    Teledyne Marine RD Instruments

    For decades, Teledyne RD Instruments has been the preeminent supplier of Acoustic Doppler Current Profiling (ADCP) instrumentation for open ocean applications. Teledyne RDI’s vessel-mounted Ocean Surveyor family of ADCPs continues to raise the bar, collecting detailed maps of the distribution of water currents and suspended materials through the water column and along the ship’s path - at depths and resolutions previously considered unattainable. In real time, the ADCP is also used to aid in situ decision-making, to adapt field operations, and to understand current regime characteristics.

  • High Voltage Ammeter

    Ampstik®+ - SensorLink

    Use the Ampstik+ to safely take accurate current measurements when performing high voltage live-line load checks for balancing, switching, or breaking load. This high voltage ammeter measures in every electric utility setting with a linear current sensor to accurately measure .5A to 5000A, while in voltage environments up to 500kV. The opening of the amp sensor is electronically closed, while external currents are electronically rejected. This design enables the user to measure an individual conductor within close proximity to adjacent conductors without interference errors.

  • Software-controlled Generator

    IPTN16 - Holding Informtest

    *The module provides output of constant stabilized voltage through 16 independent channels in 2 ranges ± 2 V and ± 10 V with a step of 5 mV, as well as a stabilized current of ± 10 mA with a step of 5 μA.The IPTN16 module is intended for use in information measuring VXI systems and can be used to power resistive temperature sensors or strain gauges with voltage or current with an accurate and stable value.*The IPTN16 module can also be used to simulate voltage or current sensors when checking measuring instruments and channels of measuring systems.

  • DC-DC Converter

    TSMC 22ULLDCDC - DOLPHIN Design

    *Ultra-low quiescent current (< 250 nA) to ensure minimum current consumption in deep sleep / hibernation mode*High efficiency at light load to extend battery lifetime*Low ripple value to supply noise sensitive and RF loads*1 uH inductor*Ultra-small area for reduced silicon cost

  • DPS & PMU

    Analog Devices Inc.

    Analog Devices parametric measurement units (PMU) and device power supply (DPS) products provide a flexible range of voltage and current source/measurement capability to meet a wide range of cost-sensitive test application needs. The DPS will source currents to 1.2A and multiple devices can be ganged for even higher power applications.

  • Loop Meter

    MZC-304 - Sonel S.A.

    # Measurements of impedance in a short circuit loop.- L-PE circuit,- L-N, L-L circuit,- L-PE(RCD) circuit - without tripping the circuit breaker > 30mA.# Low voltage resistance measurement:- continuity measurement - DC current +200mA with wire resistivity reset- low current resistance measurement with accoustic signalling,

  • Power Quality Analyzer

    PQA-300 - Radian Research, Inc.

    PQA-300 Power Quality Analyzer offers the latest functionality and measurement technology designed specifically for the Utility industry. The PQA-300 is a compact solution to address; Flicker PST and PLT, Voltage and Current imbalance, Sags, Dips and Swells, harmonics, inter harmonics, THD, RMS Voltage and Current, Phase and Time measurement.