  • PXI 2A Multiplexer, 4-Bank, 16-Channel 2-Pole

    40-614-007 - Pickering Interfaces Ltd.

    The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.

  • PXI 2A Multiplexer, 1-Bank, 64-Channel 2-Pole

    40-614-016 - Pickering Interfaces Ltd.

    The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.

  • Mini-Test Station

    Fuel Cell Technologies, Inc

    Mini-Test Station for low current fuel cell testing. The test station includes Analog mass flow controllers for Anode and Cathode gas streams, humidity bottles with preheaters and temperature controllers and a cell temperature controller. The test station is designed to use the customer's Potentiostat to load the cell. Manual backpressure is provided for pressures from 0-60 psig. The Mini-Test station is basically our Analog Mass Flow Controlled Low Flow Humidification System with all the options.

  • PXI Single 8x4 1-Pole 10A Power Matrix

    40-551-001 - Pickering Interfaces Ltd.

    Used for switching inductive/capacitive loads up to 10A with 125VDC/250VAC hot switching and 400VDC/250VAC cold switching. X and Y connections are made via a 20-way GMCT plug, also available with loop-thru has an additional 20-way GMCT plug for module-to-module connection. Power Matrix Modules are intended for switching heavy AC or DC loads or for slaving large external relays, contactors and solenoids. Suitable for applications requiring switching of either mains voltage or direct current.

  • PXI Single 4x4 1-Pole 10A Power Matrix

    40-551-003 - Pickering Interfaces Ltd.

    Used for switching inductive/capacitive loads up to 10A with 125VDC/250VAC hot switching and 400VDC/250VAC cold switching. X and Y connections are made via a 20-way GMCT plug, the 8x4 module with loop-thru has an additional 20-way GMCT plug for module-to-module connection. Power Matrix Modules are intended for switching heavy AC or DC loads or for slaving large external relays, contactors and solenoids. Suitable for applications requiring switching of either mains voltage or direct current.

  • Plug Socet & Cord Testing

    Educated Design & Development, Inc.

    Flexing Tests: On flexible cables (or cords sets with fitted plugs), electric tools or hand lamps. Meets requirements of standards such as IEC 60335, IEC 60227, IEC 60745 and UL745. This product is for continuous bending tests of cables or cord sets fitted with plugs. The model F39 allows the simultaneous testing of two samples in it's standard version. This not only allows for substantial time savings, but also allows for the testing current circuits to be simplified by looping through the cables.

  • Single Head Component Testers

    34XX - FETservice, Inc

    Performs DC, AC, and pulsed tests. Excels at evaluating difficult to measure parameters on zeners, current limiters, varactor tuning diodes, darlingtons and matched dual transistors. 24 bin opto-isolated handler/prober interface. Parallel first-in first out computer to tester interface for maximum throughput. Parallel testing with a 3402E or 3403E allows shared test execution for extremely high throughput applications when interfaced to high speed handlers with multiple test sites.

  • FC Impedance Meters

    Kikusui Electronics Corp.

    designed for testing of the fuel cell with the small current (5 A or less), and not only the current-voltage characteristic test, the KFM2005 can easily measure for the impedance of a fuel cell using the AC impedance method, and the Cole-Cole plot. Using the measurement data of the Cole-cole plot, it is possible to calculate the circuit constant of the approximate equivalent circuit of the fuel cell. The built-in DC load (60W) is capable to operate from 0 V, and it can perform the test for the fuel cell up to 20V and 5A.

  • DC Power Supplies

    XG 850 - AMETEK Programmable Power, Inc.

    The Sorensen XG Series is an 850 Watt, 1U half-rack DC power supply. The XG Series is the new standard for powerful, programmable DC power systems. Designed for test, production, laboratory, OEM and quality assurance applications, the XG Series provides a wealth of features to ensure accuracy and greater efficiency. It puts clean, reliable power at your disposal and delivers stable, variable output voltage and current for a broad range of development, test and system requirements.

  • Ground Earth Resistance Tester

    2678X - Shenzhen Chuangxin Instruments Co., Ltd.

    Ground Earth Resistance Tester verifies the integrity (continuity) of the protective bonding of the equipment (Class I equipment) designed to secure safety through the basic insulation and protective earthing. It is also called earth (ground) bonding test. If the continuity of the protective bonding is confirmed, we can conclude that the equipment has the requirements for preventing electric shock even if the insulation between the primary circuit and the accessible conductive section fails and a fault current flows through the distribution system.

  • 6U Form Factor PMC/PrPMC Carrier-VMEbus

    i4400 - AcQ Inducom

    The i4400 is a low-cost 6U form factor PMC / PrPMC carrier for the VMEbus and forms the basis of a flexible I/O system. It offers the user a means of integrating two single PMC modules or one double PMC module in a VMEbus system. The current version of the i4400 supports PMC modules and also supports Processor PMC modules on one PMC-site. The VME-to-PCI bridge is implemented in an FPGA for flexible VME-to-PCI mapping and to allow future updates and upgrades.

  • Bench top Dielectric Withstand tester

    HYPOT III - Wavecontrol, S.L.

    RS-232 Interface available for automated controlPatented SmartGFI® functionPatented CAL-ALERT® functionComes complete with a test box for products terminated in a line cordPatented VERI-CHEK® functionStorage of up to 10 setups with 3 steps per setupBuilt-in security settingsDigitally controlled arc detection systemNo load setup of trip current and output voltageElectronic ramping (up & down)Built-in adjustable continuity testInterconnection to HYAMP® III to form complete test system

  • SCR Rectifiers

    Carl E. Holmes Company

    SCR-controlled rectifiers are electronically controlled via analog signals for constant voltage and current control. The compact and service-friendly design complies with high industrial requirements and guarantees excellent operational reliability.The input voltage can be from 208 VAC to 600 VAC, 3 PH, 50/60 Hz. Maximum output voltage can be from 6 VDC to 600 VDC. Maximum output can be from 1000 Amps to 100000 Amps. These units can be air cooled, water cooled or oil cooled.

  • Ground-Fault Location Products for Ungrounded Systems

    Bender Inc.

    When combined with Bender's ground-fault detectors and current transformers, EDS series modules provide fast, automatic ground-fault location in ungrounded systems. Fault location takes place while the system remains online without the need to open branch circuit breakers or disconnect equipment. Bender's fault location system works on both AC and DC systems, as well as systems with variable frequency drives. A standalone, portable fault location system is also available.

  • MCB Thermal Trip Calibration Test Bench (IEC 60898 Cl 9.10.1.2, Annex I.1, IS)

    SCR ELEKTRONIKS

    The test system is designed and customized to carry out 2.55*Intest as per Table 7 (test c) of IEC 60898 (also mentioned for routine testing of MCBs. The test is done at dc current to exactly analyze and correct the bimetallic properties of the MCB as far as thermal tripping is concerned. The unit comes with a pneumatically operated test fixture with in-built dc stepper motor that is controlled by a micro controller / PC to calibrate the breaker into a narrow tripping band programmed by the user.