Filter Results By:

Products

Applications

Manufacturers

Relay

electromechanical or semiconductor switches.

See Also: General Purpose Switch


Showing results: 3961 - 3975 of 4029 items found.

  • USB Controlled Multi-Function DAQ For ATE Education And ATEasy Training

    GT98901 Series - Marvin Test Solutions, Inc.

    The GT98901 Demo board is a USB controlled, cost-effective, multi-function PCB assembly. The module is completely self-contained and includes an LCD display, measurement and stimulus resources, digital I/O, relays, and switches – all of which can be accessed and monitored via the USB port using a SCPI command set via a USBTMC interface which supports the USB488 protocol. Power for the board is provided via the USB interface, providing a totally self-contained assembly which can provide users with a simple yet complete vehicle that replicates many of the stimulus and measurement functions associated with ATE systems. When combined with Marvin Test Solutions' ATEasy® Test Executive and Test Development environment, the GT98901 is the ideal product for creating and supporting ATE training and education applications.

  • 32 Channel Analog Comparator Module

    DP-VXI-5106 - Data Patterns Pvt. Ltd.

    DP-VXI-5106, is a 32 Channel Analog Comparator Module with 32 channels of differential analog window comparators. Each channel is provided with a window comparator as well as a Level Comparator , software selectable on an independent channel basis. All the 32 channels have been grouped into four groups of 8 channels each. This allows the user to configure the comparator module based on the application to initiate alarm action to exactly meet application requirements. Each Comparator channel can be programmed to generate a VXI bus interrupt or can be masked through software. An Interrupt is generated on an individual channel basis or on a group basis. Front panel outputs of buffered TTL and a 2-CO relay contact is available for every group (4 outputs total each). Also, a common buffered TTL interrupt output and a common 2-CO relay contact is also available at the facia providing extensive flexibility in application engineering.This module is an ideal device for GO / NO-GO testing in Test Stand Automation where important signals must be continuously monitored for system shut down purposes and safety inter-lock implementation. The hardware implementation in the Comparator module provides high-speed throughput and reliable inter-lock implementation. The interrupt out signal can be further wired as trigger signals for pre and post trigger analysis of signal data for post acquisition detailing.Each channel provides a Window Comparator implementation and a Level Comparator implementation. The configuration is programmable through software and the alarm can be generated if the signal is within the window or outside the window. Similarly, a high and low limit can be set and a trigger is generated if the signal exceeds the high limit or drops below the low limit.

  • Enlarge Environmental Chamber

    REXMED REC-450 - REXMED Industries Co., Ltd.

    MOD. REC-450, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -40˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 1.5KW X 2pcs, Humidity heater: 2.5KW X 1pc, Heat up transition time: -40˚C~100˚C within 45 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 3,644 Watts, 12,433 BTU/hr, 3,140 Kcal/hr, Cool down transition time: 20˚C~-40˚C within 50 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L60 X W80 X H85cm, Capacity: 408L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

  • Enlarge Environmental Chamber

    REXMED REC-250 - REXMED Industries Co., Ltd.

    MOD. REC-250, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -20˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 1.5KW X 2pcs, Humidity heater: 2.5KW X 1pc, Heat up transition time: -20˚C~100˚C within 35 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 3,140 Watts, 10,700 BTU/hr, 2,702 Kcal/hr, Cool down transition time: 20˚C~-20˚C within 45 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L60 X W80 X H85cm, Capacity: 408L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

  • Environmental Chamber

    REXMED REC-400 - REXMED Industries Co., Ltd.

    MOD. REC-400, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -40˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 1.5KW X 2pcs, Humidity heater: 2.5KW X 1pc, Heat up transition time: -40˚C~100˚C within 45 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 3,506 Watts, 11,962 BTU/hr, 3,020 Kcal/hr, Cool down transition time: 20˚C~-40˚C within 50 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L50 X W60 X H75cm, Capacity: 225L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

  • Environmental Chamber

    REXMED REC-280 - REXMED Industries Co., Ltd.

    MOD. REC-280, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -20˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 2.3KW X 2pcs, Humidity heater: 4.5KW X 1pc, Heat up transition time: -20˚C~100˚C within 35 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 3,140 Watts, 10,700 BTU/hr, 2,702 Kcal/hr, Cool down transition time: 20˚C~-20˚C within 45 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L100 X W80 X H100cm, Capacity: 800L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

  • Enlarge Environmental Chamber

    REXMED REC-480 - REXMED Industries Co., Ltd.

    MOD. REC-480, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -40˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 2.3KW X 2pcs, Humidity heater: 4.5KW X 1pc, Heat up transition time: -40˚C~100˚C within 45 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 5,270 Watts, 18,000 BTU/hr, 4,545 Kcal/hr, Cool down transition time: 20˚C~-40˚C within 50 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L100 X W80 X H100cm, Capacity: 800L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

  • Environmental Chamber

    REXMED REC-200 - REXMED Industries Co., Ltd.

    MOD. REC-200, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -20˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 1.5KW X 2pcs, Humidity heater: 2.5KW X 1pc, Heat up transition time: -20˚C~100˚C within 35 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 1,892 Watts, 6,455 BTU/hr, 1,630 Kcal/hr, Cool down transition time: 20˚C~-20˚C within 45 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L50 X W60 X H75cm, Capacity: 225L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

  • Battery Tester

    G5.BT - Regatron AG

    The G5.BT series is bidirectional regenerative. It was developed specifically for testing energy storage devices and is suitable for use in laboratories and on test benches. The modular and finely graded G5.BT series is characterized by highly dynamic response times and a wide current-voltage range with an auto-ranging factor 3. The G5.BT series has an outstanding current accuracy of <0.02% FS, an additional high-resolution current measurement range, and a fast current rise time in the 100 μs range. Ripple modulation, an integrated safety relay for PL c according to EN ISO 13849 and a powerful CAN multi-protocol interface (1 kHz, 16 bit) as well as functions to avoid reverse-polarity problems, current surges, and unwanted deep discharges make the G5.BT series the ideal, versatile battery module and battery pack tester.

  • Multifunctional Meter

    CPM-10 - Chuan Sheng Electronics Co., Ltd.

    CPM-10 Multifunction Power meter measure single phase 2 wire ,single phase 3 wire, three phase 3 Wire and 3 Phase 4 wire systems with high accuracy measurement for parameters such as voltage, current ,active power, reactive power, apparent power, power factor ,frequency, effective energy (V,A,W,Watt-Hr,Var,Var-Hr,VA,PF,Hz), having LED display and standard communication RTU Modbus RS485..Optional functions 1 set relay output,1 analogue,1 RS485 (ModbusRTU Mode) or 1 pulse output. Most suitable for power management,remote input /output, alarm and remote signal control uses needs.Case depth 120mm only, easy panel mounting installation

  • Ethernet/AFDX/BroadR-Reach PXI Fault Insertion Switch - 4 Channel

    40-201-004 - Pickering Interfaces Ltd.

    This high bandwidth differential fault insertion module is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This module supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.

  • Ethernet/AFDX/BroadR-Reach PXI Fault Insertion Switch - 8 Channel

    40-201-008 - Pickering Interfaces Ltd.

    This high bandwidth differential PXI fault insertion module is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This module supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.

  • HSI Test Fixture

    TA-552 - Tech-Aid Products

    This test fixture provides the necessary panel controls, switching and cable pin-outs required to test the KPI-552/KPI-553/A series of HSI's as described in their respective maintenance manuals. This fixture will serve as the "Instrument Bench Tester" and does have the required differential resolvers and relay switching. Panel jacks are provided for the Heading, Course, RMI and ADF synchro sources that are external to this fixture. The use of external synchro sources serves to minimize the cost of this panel. Additional items incorporated on the panel are test jacks to monitor the meter drive voltage and current as well as a momentary switch to open the meter drive and this serves to verify sticky meter stops. The fixtures rear panel provides for all power inputs as well as an I/O connector if the shop desires to interface an external synchro panel.

  • Physical Layer Switching Systems for copper LAN, WAN, DSL, Telco apps with RJ style connectors.

    RJ Series - Cytec Corp.

    The RJ Series of computer controlled switching systems are designed for physical layer switching of multiwire signals on RJ style connectors. Since the system uses mechanical relays it acts exactly like a piece of cable which makes it perfect for testing networks without altering the signals or regeneration. These systems are typically used for Ethernet LAN 10BaseT through 1000BaseT, DSL including ASML through GFAST, CAT5 through CAT6A cable testing, USB up to 2.0, RS232, RS422, RS485 up to 8 wire at 20 Mbps and many other applications switched over RJ45 connectors up to 8 wires. They may also be used as lab automation switches, network testing switches, patch panels, network redundancy switches or any number of physical layer applications.

  • Fluxmeter

    480 - Oersted Technology

    The Model 480 is a laboratory grade fluxmeter, for use with a Helmholtz coil or custom search coils. This instrument measures the total flux of a magnet part, which can be related to the magnetic field strength. Applications include magnet testing, magnetizing, and automated field measurement. In order to provide accurate and repeatable measurements, automatic or manual drift compensation is available to the user. A peak mode allows even the fastest magnetic pulse, such as those from a magnetizer, to be accurately measured. The Model 480 is also useful for measuring AC fields that are too high in frequency for a gaussmeter to detect. Relay outputs and an external reset input allow for simple automation functions to be implemented, while the RS232C and IEEE-488 ports permit advanced control of the fluxmeter via a remote computer or automation equipment.

Get Help