PXI 12-Slot BRIC Matrix, 660x4 2-Pole (15 sub-cards)
40-562B-322-660X4
The 40-562B-322-660X4 is a high density BRIC12 matrix module with a size of 660x4 with 2-pole switching. It is part of a range of BRIC matrices available in 2, 4, 8 or 12-slot formats to suit high performance PXI matrix requirements and is constructed using instrumentation quality reed relays.
-
product
PXI/PXIe Microwave Multiplexer, Single SP6T, 18 GHz, 50 Ω, SMA, Failsafe
42-785C-521
The 40-785C-521 (PXI) and 42-785C-521 (PXIe) are single failsafe SP6T 18 GHz unterminated microwave multiplexers. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
product
PXI 5A Power MUX, 8-Bank, 5-Channel
40-651-004
This range of high density power multiplexer modules is suitable for switching inductive/capacitive loads up to 5A at 250VAC. It is available in the following 1-pole multiplexer formats: 1-bank 48-channel. 2-bank 24-channel. 4-bank 11-channel. 8-bank 5-channel. Connections are made via a front panel 50-way male D-type connector. Power multiplexer modules are intended for switching heavy AC or DC loads or for slaving up to large external relays, contactors and solenoids.
-
product
Relay I/O Module via Ethernet
2650
8 form-C mechanical relays with 240VAC, 2A ratingConnects to an Ethernet through 2601 hub100 mm DIN carrierResponds to interlock and E-stop circuitsWatchdog TimerCompatible with Linux and WindowsUse our design assistant to configure a system and calculate pricing
-
product
LXI Reed Relay Matrix - Dual 64x8 Plugin, Direct Y Access, 6 Analog Buses
65-223-001
The range includes four plug-in models covering matrices of up to 1,536x4 in increments of 128 (model 65-221), 768x8 in increments of 64 (model 65-223), 384x16 in increments of 32 (model 65-225), and 192x32 in increments of 32 (model 65-227). Users can specify as many or as few plug-in modules (up to six) required and can field upgrade the chassis to extend the matrix when necessary. Another important feature is that over 1,500 relays can be closed simultaneously for specific conditions for parametric testing.
-
product
PXI/PXIe High Voltage Multiplexer, Dual 4-Channel, 1-Pole
42-321-100-HI
The 40-321-100-HI (PXI) and 42-321-100-HI (PXIe) are dual 4-channel 1-pole high voltage multiplexers capable of hot or cold switching up to 1000 V peak. They are also available in a range of bank sizes with 1 or 2 poles and channel counts between 4 and 48. High quality reed relays are used throughout.
-
product
PXI/PXIe Microwave Relay, Triple SPDT, 2.5 GHz, 75 Ω, 1.6/5.6, Remote Mount, Failsafe
42-780B-753-E
The 40-780B-753-E (PXI) and 42-780B-753-E (PXIe) are triple failsafe SPDT 2.5 GHz 75 Ω unterminated microwave relay modules with remotely mounted relays. The 40/42-780B range is available with one, two, three or four SPDT panel mounted relays capable of switching frequencies up to 67 GHz in 50 Ω or 2.5 GHz in 75 Ω. Connections are made via high quality RF coaxial connectors, SMA or N-Type for 50 Ω and 1.6/5.6 in 75 Ω versions. Remote versions can support up to three SPDT relays in a single slot.
-
product
PXI 8-Slot BRIC Matrix, 87x8 2A 2-Pole (3 Sub-cards)
40-565B-102-87X8
These modules are 2 Amp high-density large PXI matrix modules with the ability to switch up to 2 Amps at 150VDC/100VAC. These 2A switch matrix modules are available in 2, 4 or 8-slot PXI sizes for most high-performance PXI matrix requirements. Constructed using quality electro-mechanical relays for high switching confidence.
-
product
EtherCAT Slave System
EPS Series
The ADLINK complete EtherCAT solution, from hardware to middleware to software, with every element tailored for dedicated EtherCAT functionality, includes PCIe-833X Series master controllers, EPS slave systems, and remote monitoring and control providers. As well, ADLINK’s Softmotion one-stop control kernel delivers flexible and easy-to-use intelligent platforms for driving next-generation modern Smart Factories. ADLINK's EPS slave system brings the power the flexibility to EtherCAT environments...show more -
product
PXI 5A MUX, 2-Bank, 24-Chan, Ind. Isolation
40-651-102
This range of high density power multiplexer modules is suitable for switching inductive/capacitive loads up to 5A at 250VAC. It is available in the following 1-pole multiplexer formats: 1-bank 48-channel. 2-bank 24-channel. 4-bank 11-channel. 8-bank 5-channel. Connections are made via a front panel 50-way male D-type connector. Power multiplexer modules are intended for switching heavy AC or DC loads or for slaving up to large external relays, contactors and solenoids.
-
product
PXI Microwave Multiplexer, Single SP6T, 26.5GHz, 50Ω, SMA, Terminated
40-785C-531-T
The 40-785C-531-T (PXI) and 42-785C-531-T (PXIe) are single SP6T 26.5GHz microwave multiplexers with automatic termination of unused signals. The 40/42-785C range of multiplexers are available as single or dual, SP6T or SP4T panel mounted multiplexers with relays mounted on the front panel. The single slot version can support up to three supplied remotely mounted multiplexers.
-
product
PXI/PXIe High Voltage Multiplexer, Hex 7-Channel, 1-Pole
40-321-103-HI
The 40-321-103-HI (PXI) and 42-321-103-HI (PXIe) are hex 7-channel 1-pole high voltage multiplexers capable of hot or cold switching up to 1000 V peak. They are also available in a range of bank sizes with 1 or 2 poles and channel counts between 4 and 48. High quality reed relays are used throughout.
-
product
USB-6509, 96-Channel, 5 V, TTL/CMOS, 24 mA, USB Digital I/O Device
779975-01
The USB-6509 is an industrial, bus-powered USB device that can directly drive external digital devices such as solid-state relays (SSRs). You can configure each port for input or output, and no external power supply is … required for outputs. Using programmable power-up states, you can configure the initial output states in software to ensure glitch-free, safe operations when connected to industrial actuators. If a computer or application fault occurs, the USB-6509 can use digital I/O watchdogs ...show more -
product
PXI/PXIe High Voltage Multiplexer, Single 48-Channel, 2-Pole
42-321-129-HI
The 40-321-129-HI (PXI) and 42-321-129-HI (PXIe) are single 48-channel 2-pole high voltage multiplexers capable of hot or cold switching up to 1000 V peak. They are also available in a range of bank sizes with 1 or 2 poles and channel counts between 4 and 48. High quality reed relays are used throughout.
-
product
PXI/PXIe Microwave Multiplexer, Dual SP10T, 22 GHz, 50 Ω, SMA, Terminated, Remote Mount, Failsafe
42-788-132-TE
The 40-788-132-TE (PXI) and 42-788-132-TE (PXIe) are dual failsafe SP10T 22 GHz microwave multiplexers with automatic termination of unused signals and remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
product
PXI/PXIe High Voltage Multiplexer, Single 48-Channel, 1-Pole
40-321-109-HI
The 40-321-109-HI (PXI) and 42-321-109-HI (PXIe) are single 48-channel 1-pole high voltage multiplexers capable of hot or cold switching up to 1000 V peak. They are also available in a range of bank sizes with 1 or 2 poles and channel counts between 4 and 48. High quality reed relays are used throughout.
-
product
PXI/PXIe RF Multiplexer, Single 4-Channel, 3GHz, 50Ω, SMB
40-872A-001
The 40-872A-001 (PXI) and 42-872A-001 (PXIe) are 50 Ohm 4 to 1 RF multiplexers with 1 bank in a single slot. They have low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. Each MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz with each path having a nominally equal insertion loss. The injection of noise and unwanted signals into the signal paths of the 40/42-872A has been minimized by careful attention to the mechanical and electrical design.
-
product
PXI 1A Fault Insertion Switch 22-Channel
40-195-001
The 40-195 is a 22 Channel Fault Insertion Switch, primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert different fault conditions on pairs of signals between the test fixture and the equipment under test: Open-Circuit, Short-Circuit between signal pairs, Short-Circuit between signal pairs and user applied fault conditions e.g. Power or GND. Relays ...show more -
product
PXI/PXIe Microwave Multiplexer, Dual SP6T, 3 GHz, 50 Ω, N-Type, Remote Mount, Failsafe
42-785C-562-E
The 40-785C-562-E (PXI) and 42-785C-562-E (PXIe) are dual failsafe SP6T 3 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
product
Digital Panel Mount Load Cell Meter
MODEL DPM-3
The DPM-3 is a smart Plug & Play TEDS IEEE 1451.4 compliant Digital Panel Mount Load Cell meter. Just plug in a TEDS compatible Load Cell or Torque Sensor and the DPM-3 will automatically self-calibrate. When used with a non-TEDS Load Cell or Torque Sensor, the DPM-3 can be set up by simple front panel push buttons. The DPM-3 can be scaled to a full 5 digit display from 0 to 99,999 counts to read directly in engineering units such as grams, ounces, pounds, etc. The DPM-3 samples 60 reading...show more -
product
PXI 2A Multiplexer, 4-Bank, 4-Channel, 8-Pole
40-614B-009
This 4-bank, 4-channel, 8-pole version is part of the 40-614B High Density 2A multiplexer module range that is available in 20 configurations (see Also in this Range link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
product
PXI/PXIe Microwave Multiplexer, Single SP6T, 40GHz, 50Ω, SMA-2.9
40-785C-541
The 40-785C-541 (PXI) and 42-785C-541 (PXIe) are single SP6T 40GHz unterminated microwave multiplexers. The 40/42-785C range of multiplexers are available as single or dual, SP6T or SP4T panel mounted multiplexers with relays mounted on the front panel. The single slot version can support up to three supplied remotely mounted multiplexers.
-
product
AC Clamp Meter
ST-2600
Standard Electric Works Co., Ltd
● Full auto range for V.A and Ω functions. ● Data hold function freezes the reading in dimly lit or hard to reach places. ● Low battery indication. ● Built-in buzzer for continuity test.● Safety design throughout with no exposed metal parts. Shielded banana plugs and recessed input terminals.● Ohm function ideal for checking continuity of relays transformers and motor coils.
-
product
PXI 24x4 Matrix, 2 Pole Switching
40-513-022
The 40-510 series of matrix modules feature a wide range of selectable switchingconfigurations (12x4,dual 12x4,12x8 and 24x4). Typical applications include signalrouting in ATE and data acquisition systems.Available reed relay formats are 1-pole, 2-pole and 1-Pole screened. The screenedversion is suitable for switching signals up to 50MHz. Larger matrices may be constructedby Daisy Chaining the common signals from multiple PXI modules.
-
product
SP4T Microwave Switch Plug-In
1260-164AH/BH
The Astronics 1260-164AH/BH is a 2-slot microwave switch plug-in available in two standard configurations with either one or two relays, each being SP4T, 1-pole, 4-throw.
-
product
PXI Microwave Multiplexer, Dual SP4T, 26.5GHz, 50Ω, SMA, Terminated
40-785C-432-T
The 40-785C-432-T (PXI) and 42-785C-432-T (PXIe) are dual SP4T 26.5GHz microwave multiplexers with automatic termination of unused signals. The 40/42-785C range of multiplexers are available as single or dual, SP6T or SP4T panel mounted multiplexers with relays mounted on the front panel. The single slot version can support up to three supplied remotely mounted multiplexers.
-
product
Relay Test Bench
VAE-430
The VAE-430 protective relay tester is designed to test all the major protection testing projects, including the 27 underfrequency protection, 59 overcurrent protection, 67 undervoltage protection, 81 overfrequency protection, 87 differential protection, 51 time overcurrent protection, 50 boundary protection, 21 distance protection, 86 rate of change of frequency protection, and 32 directional power protection, and others.
-
product
PXI 8-slot BRIC Matrix, 924x6, 1 Pole (11 Sub-cards)
40-558-801-924x6
The 40-558-801-924x6 matrix is part of a range of BRIC ultra-high-density large PXI matrices are available in 2, 4, 8 or 12-slot PXI sizes to suit all high-performance matrix requirements and are constructed using Pickering Electronics' 4mm x 4mm instrumentation quality reed relays.
-
product
PXI 12-Slot BRIC Matrix, 224x16 1-Pole (7 sub-cards)
40-558-121-224X16
The 40-558-121-224x16 matrix is part of a range of BRIC ultra-high-density large PXI matrices are available in 2, 4, 8 or 12-slot PXI sizes to suit all high-performance matrix requirements and are constructed using Pickering Electronics' 4mm x 4mm instrumentation quality reed relays.