Showing results: 3421 - 3435 of 4029 items found.
-
ABB Ltd.
Test switches are designed and manufactured to allow quick and easy multi-circuit testing of switchboard relays, meters and instruments by any conventional system.These test switches and related test plugs have the features necessary for applications involving the measurement of individual currents and voltages associated with substation instrumentation and protection devices. They have been especially designed for the measurement of potential elements, current elements, and make-before-break short-circuit elements related to Current Transformer (CT) circuits.
-
SecuControl inc.
FTL testblock with dust cover and current disconnect pinThe FTL is a test block for interfacing substation devices (protection relays, fault recorders, revenue meters, ... ) to the voltage and current transformers and to other equipment on the system side of a power grid. The FTL test block uses disconnect pins to isolate the substation devices from the system side equipment. Once isolated, secondary injection can be performed using banana jacks on the front side of the test block.
-
ProDAQ 6140 -
Bustec Ltd.
The ProDAQ 6140 provides a relay matrix which can be fitted between the sensors and actuators on a device under test and the data acquisition and control system. It allows to separately connect/disconnect the signals from either side and to connect them to an internal bus. In this way signals can be routed via the bus to new destinations or the bus can be used to monitor or supply test signals. This allows calibrating and debugging the system without disconnecting and separating channels throughout the system wiring.
-
PCIe-7432 -
ADLINK Technology Inc.
ADLINK PCIe-7432 is a 32CH Isolated DI & 32CH Isolated DO PCIe Card, featuring robust 2,500V isolation protection, suitable for most industrial applications. Input range up to 24V makes it easy to acquire status of external devices (PCIe-7432HIR output range is from 5 to 35V), making it suitable for relay driving and industrial automation applications. Also provided are two easily configurable interrupt sources on digital input channels.
-
ABex TM-1149Cx-FXT -
Konrad Technologies GmbH
The ABex TM-1149Cx-FXT is an ABex terminal module for the Göpel Boundary Scan Controller SFX/PXI(e) 1149/C4-FXT-X. It is connected to the BSCAN-Controller with an adapter-paddle-card.In combination with the above Göpel Boundary scan card it’s possible to connect up to four JTAG/Boundary Scan TAPs. All differential signal wires on the PCB are impedance controlled. In addition, all other digital signals (PIP, TRG, Aux, I/O) and Ground can be switched off via relays.
-
ABex TM-JT37x7 -
Konrad Technologies GmbH
The ABex TM-JT37x7 is an ABex terminal module for the JTAG Technologies Boundary Scan Controller PXI/PXIe JT 37×7. In combination with the JT 2147/ABex from JTAG Technologies it integrates the POD functionality into the module.In combination with the PXI/PXIe JT 37×7 and the JT 2147/ABex it’s possible to connect up to four JTAG/Boundary Scan TAPs. All signal wires on the PCB are impedance controlled. In addition, all signals can be switched off via relays.
-
782385-13 -
NI
The TB-2646B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire dual 4x32 or 1-wire quad 4x32 matrix. You can directly connect the TB-2646B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2646B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
782385-14 -
NI
The TB-2646B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire dual 4x32 or 1-wire quad 4x32 matrix. You can directly connect the TB-2646B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2646B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
MODEL DPM-3 -
Transducer Techniques, Inc
The DPM-3 is a smart Plug & Play TEDS IEEE 1451.4 compliant Digital Panel Mount Load Cell meter. Just plug in a TEDS compatible Load Cell or Torque Sensor and the DPM-3 will automatically self-calibrate. When used with a non-TEDS Load Cell or Torque Sensor, the DPM-3 can be set up by simple front panel push buttons. The DPM-3 can be scaled to a full 5 digit display from 0 to 99,999 counts to read directly in engineering units such as grams, ounces, pounds, etc. The DPM-3 samples 60 readings per second (50 for 50Hz operation) for fast control response and true peak/valley reading capability. The meter has an adaptive digital filter that can automatically select the best time constant for minimum noise, yet respond rapidly to an actual change in signal level. The peak and valley values can be displayed by a push of a button on the front panel. Auto-tare allows the meter to be set to zero for any input signal level. Available options include dual relays, analog output, serial communications, and low voltage power supply.
-
ICS Electronics
ICS's Ethernet Parallel Digital Interface boards provide the user with a wide range of IO signals that can be user configured to match virtually any application. These Ethernet boards are available with high power relay driver boards and with optional firmware designed to simplify switching applications. The 80x3 boards have high-power TTL signals that can sink 48 mA and source 24 mA. Pullup resistors make it easy to interface with CMOS logic and to sense contact closures. User configures data byte direction and polarity. The 80x3 boards are VXI-11 compliant for operation with NI or Agilent VISA, LabVIEW and VEE and support raw socket connections. The new 8113 board is a CMOS close of the 8013 board with user set 3.3 or 5 V logic levels. Pinouts and command set is the same as the 8013 board. The 8113 communicates with TCP/IP(Raw Socket) protocoland and also has a RS-232 Serrial Port. All boards are designed for mounting against the rear panel or inside a chassis and use our Ethernet Wiring Kit for easy connection to a Ethernet Connector on the rear panel.
-
LX-08 -
Link Instruments
The LX-08 series of high voltage logic analyzer adapters provides a safe isolated method of measuring high voltage control signals with a low voltage logic analyzer. All inbound signals are optically isolated and attenuated to a safe level for the delicate inputs typically found on logic analyzers. The inputs on the LX-08 are capable of withstanding voltages up to +/- 300V AC/DC, higher voltage configurations are available upon request. Rather than probing with multiple neon screwdrivers, the LX-08 can provide simultaneous viewing of up to 8 circuits in the STANDALONE mode via the indicator array. Need to catch a transient event or map out a timing sequence? Just add a logic analyzer to the outputs of the LX-08 and turn it into a high voltage logic analyzer. High voltage signals that were hazardous for a logic analyzer can now be measured safely. Typical outputs of a high speed PLC sequencer can be precisely timed and measured from both sides of the control relay. With the built in user selectable AC filter circuit, an AC signal can be measured as DC events or AC cycles.
-
MODEL SST-HV -
Transducer Techniques, Inc
The SST-HV is a Plug & Play Smart TEDS IEEE 1451.4 compliant Transmitter. Just plug in a TEDS compatible Load Cell or Torque Sensor and the SST-HV will automatically self-calibrate. When used with a non-TEDS Load Cell or Torque Sensor, the SST-LV Transmitter is easily programmed using a PC with an RS232 port and Instrument Setup (IS) software, which provides a graphical user interface. The SST-HV may be powered from 95-240 Vac ±10%. The SST-HV has an Isolated transducer excitation output that is selectable between 5Vdc or 10Vdc. There are Dual solid state relays and an Isolated 4-20 mA, 0-20 mA or 0-10V analog output. There are three Isolated serial data transmitter output ( RS232 , Half-duplex RS485, full-duplex RS485 ) and three serial protocols that are software selectable (Modbus RTU, Modbus ASCII and Custom ASCII). Isolation to 250V rms is provided for power, signal input, analog output, relay outputs, and communications. Isolation adds safety and avoids possible ground loops. The transducer excitation output is isolated to 50V from signal ground.
-
MODEL SST-LV -
Transducer Techniques, Inc
The SST-LV is a Plug & Play Smart TEDS IEEE 1451.4 compliant Transmitter. Just plug in a TEDS compatible Load Cell or Torque Sensor and the SST-LV will automatically self-calibrate. When used with a non-TEDS Load Cell or Torque Sensor, the SST-LV Transmitter is easily programmed using a PC with an RS232 port and Instrument Setup (IS) software, which provides a graphical user interface. The SST-LV may be powered from 12-30 Vac or 10-48 Vdc. The SST-HV Has an Isolated transducer excitation output that is selectable between 5Vdc or 10Vdc. There are Dual solid state relays and an Isolated 4-20 mA, 0-20 mA or 0-10V analog output. There are three Isolated serial data transmitter output ( RS232 , Half-duplex RS485, full-duplex RS485 ) and three serial protocols that are software selectable (Modbus RTU, Modbus ASCII and Custom ASCII). Isolation to 250V rms is provided for power, signal input, analog output, relay outputs, and communications. Isolation adds safety and avoids possible ground loops. The transducer excitation output is isolated to 50V from signal ground.
-
HXV Series -
Cytec Corp.
HXV products are high voltage systems intened for Hi-pot / IR or High voltage switching. They can be configured to drive from 32 to 128 switch points per chassis and can be configured as multiplexer (1xN) or Matrix (NxM) configurations. Stand HXV chassis are used for signals up to 5000 VAC rms ( 7400 V peak ) and can carry up to 5 amps of current. Custom systems can be built up to 25KV. Most of the modules used in these systems are 1xN multiplexers or 2x4 matrix modules that can be combined to form larger multiplexers or matrices. Connector options for standard HXV include 5 way banaba jacks / binding posts, Shrouded Banana Jacks or SHV ( High voltage BNC) if you need to use a high voltage cable with a grounded shield for safety applications. Control options include 10/100BaseT Ethernet LAN, RS232, GPIB or optional manual control. Standard HXV systems use high voltage reed relays. Custom HXV systems up to 25KV use application specific relays and connectors from a variety of vendors based on required specifications.
-
Neutronics Manufacturing Co.
NMC's Digital Micro Ohm Meters are low cost, compact, light weight, 3½ digit resistance meter suitable for measurements of resistances of cables, wires, transformers, motor windings, coils and contact resistance of switches, connectors, relays and track resistance of PCB's etc. The value of resistance is displayed on 7 segment LED display. Four terminal measurement systems provide measurements free from errors due to contact resistance and test lead resistance.