product
PXI/PXIe Power Relay Module, 25xSPST, 5 Amp, 50-pin D-type Connector
40-153-103
The 40/42-153-103 is a PXI/PXIe high density power relay module with 25xSPST switches rated at 5A. User connection is via a 50-pin D-type male connector. The 40/42-153 range is available in 18, 25, 36 or 50 SPST configurations with or without hardware interlock. Electro-mechanical power relays are used which are suitable for switching loads up to 5A at 250VAC.
-
product
Thermometer
H4531
Sensor H4531 is designed for online monitoring of temperature. Three binary inputs to detection of two-states signals are the advantage. Other devices are controlled by two relay outputs.
-
product
Thermocouple Vacuum Gauge Tubes for Medium Vacuum
DV-6 Series
Teledyne Hastings, manufacturer of the original DV-4, DV-5, and DV-6 thermocouple vacuum gauge tubes, produces vacuum measurement equipment with exceptional stability, accuracy, and reliability under the most demanding conditions.The Teledyne Hastings’ DV-6 series thermocouple vacuum gauge tube acts as a localized sensor which is then paired with a selection of meters or controllers to provide reliable, cost-effective measurements in diverse applications. The robust sensor gauge tube is easily ...show more -
product
Digihelic Differential Pressure Controller
DH
The Series DH Digihelic Differential Pressure Controller is a 3 in 1 instrument possessing a digital display gage, control relay switches, and a transmitter with current output. Combining these 3 features allows the reduction of several instruments with one product, saving inventory, installation time and money.
-
product
PXI/PXIe High Voltage Multiplexer, Dual 4-Channel, 2-Pole
42-321-120-HI
The 40-321-120-HI (PXI) and 42-321-120-HI (PXIe) are dual 4-channel 2-pole high voltage multiplexers capable of hot or cold switching up to 1000 V peak. They are also available in a range of bank sizes with 1 or 2 poles and channel counts between 4 and 48. High quality reed relays are used throughout.
-
product
PXI/PXIe Microwave Relay, Single SPDT, 18GHz, 50Ω, SMA
40-780B-521
The 40-780B-521 (PXI) and 42-780B-521 (PXIe) are single SPDT 18GHz unterminated microwave relay modules. The 40/42-780B range is available with one, two, three or four SPDT switches capable of switching frequencies up to 67GHz in 50Ω or 2.5GHz in 75Ω. Connections are made via front panel mounted high quality RF coaxial connectors, SMA or N-Type for 50Ω and 1.6/5.6 in 75Ω versions. Remote versions are also available which can support up to three SPDT relays in a single slot.
-
product
Keysight Dual/Quad 4x8 Reed Matrix for 34980A
34933A
The Keysight 34933A module for the 34980A Multifunction Switch/Measure Unit gives you the most flexible connection path between your device under test and your test equipment, allowing different instruments to be connected to multiple points on your device under test at the same time. Dual 4x8, 8x8, or 4x16 2-wire configurations 64 2-wire or 128 1-wire cross-points High-speed reed relays Connections to the internal DMM Expandable via four 2-wire analog buses Relay counter ±150 V peak, .5 A switch, 1.5 A carry current
-
product
PXI 4-slot BRIC Matrix, 320x8, 1 pole (5 Sub-cards)
40-558-401-320x8
The 40-558-401-320x8 matrix is part of a range of BRIC ultra-high-density large PXI matrices are available in 2, 4, 8 or 12-slot PXI sizes to suit all high-performance matrix requirements and are constructed using Pickering Electronics' 4mm x 4mm instrumentation quality reed relays.
-
product
PXI 4 Slot BRIC 22x16 2-pole (2 sub-cards)
40-562A-022-22X16
This version of our BRIC is part of a range of high-density PXI matrix modules. These modules are available in 2, 4 or 8-slot PXI sizes to suit all high performance matrix requirements and are constructed using instrumentation quality reed relays. With this high level of switching density, these PXI matrix modules allow a complete Functional ATE system to be housed in a single 3U PXI chassis. These BRIC matrix modules allow the use of lower cost 8 or 14-slot PXI chassis.
-
product
PXI Dual 12x4 Matrix, 1 Pole Switching
40-511-021
The 40-510 series of matrix modules feature a wide range of selectable switching configurations (12x4,dual 12x4,12x8 and 24x4). Typical applications include signal routing in ATE and data acquisition systems. Available reed relay formats are 1-pole, 2-pole and 1-Pole screened. The screened version is suitable for switching signals up to 50MHz. Larger matrices may be constructed by Daisy Chaining the common signals from multiple PXI modules.
-
product
PXI 4 Slot BRIC 44x8 1-Pole (2 sub-cards)
40-562A-021-44X8
This version of our BRIC is part of a range of high-density PXI matrix modules. These modules are available in 2, 4 or 8-slot PXI sizes to suit all high performance matrix requirements and are constructed using instrumentation quality reed relays. With this high level of switching density, these PXI matrix modules allow a complete Functional ATE system to be housed in a single 3U PXI chassis. These BRIC matrix modules allow the use of lower cost 8 or 14-slot PXI chassis.
-
product
Shield
Arduino Motor Shield Rev3
The Arduino Motor Shield is based on the L298 (datasheet), which is a dual full-bridge driver designed to drive inductive loads such as relays, solenoids, DC and stepping motors. It lets you drive two DC motors with your Arduino board, controlling the speed and direction of each one independently. You can also measure the motor current absorption of each motor, among other features. The shield is TinkerKit compatible, which means you can quickly create projects by plugging TinkerKit modules to the board.
-
product
PXI 4 Slot BRIC 150x8 1-Pole (5 sub-cards)
40-561A-021-150X8
This version of our BRIC is part of a range of high-density PXI matrix modules. These modules are available in 2, 4 or 8 slot PXI sizes to suit all high performance matrix requirements and are constructed using instrumentation quality reed relays. With this high level of switching density, these PXI matrix modules allow a complete Functional ATE system to be housed in a single 3U PXI chassis. These BRIC matrix modules allow the use of lower cost 8 or 14-slot PXI chassis.
-
product
PXI 8 Slot BRIC 135x16 1-Pole (9 sub-cards)
40-561A-121-135X16
This version of our BRIC is part of a range of high-density PXI matrix modules. These modules are available in 2, 4 or 8 slot PXI sizes to suit all high performance matrix requirements and are constructed using instrumentation quality reed relays. With this high level of switching density, these PXI matrix modules allow a complete Functional ATE system to be housed in a single 3U PXI chassis. These BRIC matrix modules allow the use of lower cost 8 or 14-slot PXI chassis.
-
product
LXI Reed Relay Matrix - Dual 64x8 Plugin, Direct Y Access, 6 Analog Buses
65-223-001
The range includes four plug-in models covering matrices of up to 1,536x4 in increments of 128 (model 65-221), 768x8 in increments of 64 (model 65-223), 384x16 in increments of 32 (model 65-225), and 192x32 in increments of 32 (model 65-227). Users can specify as many or as few plug-in modules (up to six) required and can field upgrade the chassis to extend the matrix when necessary. Another important feature is that over 1,500 relays can be closed simultaneously for specific conditions for parametric testing.
-
product
USB Controlled Multi-Function DAQ for ATE
GT98901
The GXT98901 Demo board is a USB controlled, cost-effective, multi-function PCB assembly. The module is completely self-contained and includes an LCD display, measurement and stimulus resources, digital I/O, relays, and switches – all which can be accessed and monitored via the USB port using a SCPI command set via a USBTMC interface which supports the USB488 protocol.
-
product
ABex Current Sense Module for Six Channel UUT Supply Monitoring
ABex TM-406 Current Sense
The ABex TM-406 is a six-channel shunt current measurement extension. It’s designed to work in combination with the Konrad ABex TM-501 and PXI-501.Each of the six shunt current measurement units have a passive measurement shunt, an overcurrent protection, a sense bridge relay and the possibility to route the quiescence current to an ABex measurement device TM-501 with PXI-501.In addition, the ABex TM-406 features 8 isolated digital outputs (IDOs), and 12 measurement inputs, which can be routed to the analog bus.
-
product
PXI 8-Slot BRIC Matrix, 2A 1-Pole 150x4, 2 Sub-cards
40-568A-102
The 40-568A-102 is a PXI 1-pole 150x4 matrix in BRIC8 format and is part of a range of high density matrix modules able to switch up to 2 A or 300VDC/250VAC. The 40-568A BRIC modules are available in 2, 4 or 8-slot PXI sizes to suit most high performance PXI Matrix requirements, constructed using high quality electromechanical relays for high switching confidence.
-
product
PXI 8 Slot BRIC 276x16 1-Pole (12 sub-cards)
40-560A-121-276X16
This version of our BRIC is part of a range of high-density PXI matrix modules. These modules are available in 2, 4 or 8 slot PXI sizes to suit all high-performance matrix requirements and are constructed using instrumentation quality reed relays. With this high level of switching density, these PXI matrix modules allow a complete Functional ATE system to be housed in a single 3U PXI chassis. These BRIC matrix modules allow the use of lower cost 8 or 14-slot PXI chassis.
-
product
PXI 2A Multiplexer, 4-Bank, 16-Channel 2-Pole
40-614-007
The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.
-
product
Safety Relay Unit for PNP Output (Equivalent) Type Light Curtain
SF-AC
Panasonic Industrial Devices Sales Company of America
Safety Relay Unit compatible up to control Category 4. This device incorporates power supply terminals and synchronization line terminals for the Light Curtain, so terminal blocks are not required.
-
product
PXI/PXIe Microwave Relay, Single SPDT, 50GHz, 50Ω, SMA-2.4, Remote Mount
40-780B-551-E
The 40-780B-551-E (PXI) and 42-780B-551-E (PXIe) are single SPDT 50GHz unterminated microwave relay modules with remotely mounted relays. The 40/42-780B range is available with one, two, three or four SPDT panel mounted relays capable of switching frequencies up to 67GHz in 50Ω or 2.5GHz in 75Ω. Connections are made via high quality RF coaxial connectors, SMA or N-Type for 50Ω and 1.6/5.6 in 75Ω versions. Remote versions can support up to three SPDT relays in a single slot.
-
product
PXI 2 Amp MUX, Quad 8-Channel 1-Pole
40-635-108
The 40-635 2 Amp Multiplexer module is available in 9 standard configurations as well as 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.The module is suitable for signal routing in ATE and data acquisition systems. Connections are made via a front panel 78-way D-type connector.
-
product
Quad 4-Channel 1-Pole 16 Amp PXI Power Multiplexer
40-662-001
The 40-662 range of 16 Amp PXI power multiplexer modules is available in seven configurations ranging from 4-off 2:1 multiplexers to 1-off 16:1 multiplexer. Power multiplexer modules are intended for switching heavy AC or DC loads or for the slave switching of large external relays, contactors and solenoids. All versions are suitable for switching loads up to 16 Amp at 250VAC. User connections are made via a 20-way GMCT plug which is fully support by our comprehensive range of cables and connector accessories.
-
product
4 2/3 Strain Gage Meter (1/32 DIN)
CS3-SG
Chuan Sheng Electronics Co., Ltd.
CS3-SG Strain Gauge Indicator has been designed with high accuracy measurement, display and communication of DC signal 0~1.0/~4.0mV or 0~10.0/~40.0mV as like as Load Cell or Strain Gauge.The meter supports Field Calibration function. It can be calibrated with sensor(Load Cell/Strain Gauge) to meet machinery structure.They are also building in 2 Relay outputs, 1 External Control Input, 1 Analogue output or 1 RS485(Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission or communication for a wide range of machinery and testing equipments applications.
-
product
PXIe-2746, 2.7 GHz, Quad 4x1 PXI RF Multiplexer Switch Module
780587-46
PXIe, 2.7 GHz, Quad 4x1 PXI RF Multiplexer Switch Module—The PXIe‑2746 is a PXI RF multiplexer switch module that is ideal for switching RF signals up to 2.7 GHz in production test applications. The high channel count of the PXIe‑2746 makes it well-suited for test systems that require switching a large number of RF signals, such as switching several devices under test to a single channel on the RF analyzer. It also features onboard relay counting for relay monitoring.
-
product
PXI High-Density Matrix Module, 16x8, 1-Pole, 2 A 60 W
40-529B-001
The 40-529B-001 is a 128 crosspoint PXI matrix with single pole switching. The matrix is configured as 16x8 using electro-mechanical relays with 2 A current handling.
-
product
12-Ch 10A-250VAC RCV Power Distribution Unit
YAVAR438
- Hardware controlled Enable Input- 12 Power relays up to 10A 250VAC/DC and 300W or 2.700VA switching power- 12 10-mOhm shunt resistors.- 6 Switched 2-Pole sense channels- Single phase isolated or 3-Phases non-isolated switching capabilities, to or from the device under test (power or load)- VPC TriPaddle 96 pins connector.- NI LabView & TestStand driver.- .NET, C/C++, VB driver.- Soft Front panel for direct interface.- CAN Control or Ethernet (with Ethernet to CAN Gateway).- Self-test module available.- Form A
-
product
PXI/PXIe High Density Electro-mechanical Relay Module, 75xSPST, Normally Open
42-145A-101
The 40-145A-101 (PXI) and 42-145A-101 (PXIe) 75xSPST relay module is part of a range of high density switching modules available in Normally Open (SPST & DPST), Changeover (SPDT) and Normally Closed (SPST) configurations. Connections are made via a front panel 200-pin female connector.
-
product
PXI 8 Slot BRIC 150x16 2-pole (10 sub-cards)
40-561A-122-150X16
This version of our BRIC is part of a range of high-density PXI matrix modules. These modules are available in 2, 4 or 8 slot PXI sizes to suit all high performance matrix requirements and are constructed using instrumentation quality reed relays. With this high level of switching density, these PXI matrix modules allow a complete Functional ATE system to be housed in a single 3U PXI chassis. These BRIC matrix modules allow the use of lower cost 8 or 14-slot PXI chassis.