Showing results: 3436 - 3450 of 4029 items found.
-
Post Glover
The main purpose of a Neutral Grounding Resistor (NGR) is to limit the fault current present in a single line to ground fault. Limiting the possible current that can flow in such an event not only reduces damage to equipment but also helps safeguard personnel in the vicinity. Depending on the design of the resistor, this current value can be either high or low, continuous or of a predetermined duration. The resistor’s designed maximum current allows relays and protection settings to be easily determined and enacted, creating a safe work environment.
-
MW(Q)-5A -
Chuan Sheng Electronics Co., Ltd.
Mx-5A meter to provide power (Watt or Active Power or Re-active Power or Power Factor), high-precision measurement, display and remote communication capabilities.Additional purchase: 1 group of relay outputs, 1 analog output, an RS485 communication output (the Modbus RTU Mode) interface, so that can be installed in power management, remote input and output, alarm and variety of remote communication control the use of needs.120mm (D) is ideal for assembling in panels with limited penetration depth.
-
MPF-5A -
Chuan Sheng Electronics Co., Ltd.
Mx-5A meter to provide power (Watt or Active Power or Re-active Power or Power Factor), high-precision measurement, display and remote communication capabilities.Additional purchase: 1 group of relay outputs, 1 analog output, an RS485 communication output (the Modbus RTU Mode) interface, so that can be installed in power management, remote input and output, alarm and variety of remote communication control the use of needs.120mm (D) is ideal for assembling in panels with limited penetration depth
-
CS2-TM-Analogue -
Chuan Sheng Electronics Co., Ltd.
The CS2-TM Totalizer controller provide high accuracy measurement, display, control and communication (Modbus RTU mode) of 0~10V/4~20mA from flow meter or mV from Shunt for Amp-Hour.There are two display screen and 3 external control input (DI) in standard and the optional 4 Relay, 1 Analogue, 1 Pulse and RS485 port available. They are also support fantastic control function as like as N, R, C mode for totalizer and batch control.
-
40-875-101 -
Pickering Interfaces Ltd.
The 40-875-101 is a single 50 Ohm 16-channel RF multiplexer in a single PXI slot. It has been designed to exhibit low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. The MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz. The design of the 40-875 Ohm minimizes the injection of noise and unwanted signals into the signal path by careful attention to the mechanical and electrical design.
-
40-875-001 -
Pickering Interfaces Ltd.
The 40-875-001 is a single 50 Ohm 16-channel RF multiplexer in a single PXI slot. It has been designed to exhibit low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. The MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz. The design of the 40-875 Ohm minimizes the injection of noise and unwanted signals into the signal path by careful attention to the mechanical and electrical design.
-
40-551-002 -
Pickering Interfaces Ltd.
Used for switching inductive/capacitive loads up to 10A with 125VDC/250VAC hot switching and 400VDC/250VAC cold switching. X and Y connections are made via a 20-way GMCT plug, the 8x4 module with loop-thru has an additional 20-way GMCT plug for module-to-module connection. Power Matrix Modules are intended for switching heavy AC or DC loads or for slaving large external relays, contactors and solenoids. Suitable for applications requiring switching of either mains voltage or direct current.
-
40-614-009 -
Pickering Interfaces Ltd.
The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.
-
40-614-013 -
Pickering Interfaces Ltd.
The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.
-
40-614-018 -
Pickering Interfaces Ltd.
The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.
-
40-614-006 -
Pickering Interfaces Ltd.
The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.
-
40-614-020 -
Pickering Interfaces Ltd.
The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.
-
40-614-017 -
Pickering Interfaces Ltd.
The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.
-
40-614-008 -
Pickering Interfaces Ltd.
The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.
-
40-614-005 -
Pickering Interfaces Ltd.
The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.