Filter Results By:

Products

Applications

Manufacturers

Probes

enable access for closer investigation.

See Also: Test Probes, Microprobes, Test Point


Showing results: 2551 - 2565 of 2823 items found.

  • Handheld UV Intensity/Power Meter

    Model 308 - OAI

    Dependable and repeatable, The OAI Model 308 UV Intensity/Power Meter is precise, direct-reading instrument designed to measure UV light intensity. The Model 308 features detachable probes for use in the UVA, UVB and UVC ranges, plus a high speed serial port and is available with an optional software package that facilitates instant data logging of intensity mode, time, wave length, serial number and calibration due date.

  • Spectrometers

    Instrument Systems Optische Messtechnik GmbH

    Optical spectrometers analyze the spectral characteristics of light radiation. Adding optical probes and absolute calibration turns this type of measurement system into a spectroradiometer. Since software is used to calculate all radiometric, photometric and colorimetric quantities from spectral data, the quality and precision of the spectrometer is extremely important. This is why Instrument Systems is dedicating most of its research and development work to this field in order to be positioned at the leading edge of technology.

  • Constant Temperature Anemometry (CTA) - Hot-Wire Anemometry - Thermal Anemometry

    Dantec Dynamics A/S

    Constant Temperature Anemometry (CTA), also known as Thermal Anemometry, is a technique for the measurement of turbulence in 1, 2 or 3-dimensional gas and liquid flows, using hot-wire or hot-film probes inserted in the flow. CTA is particularly suitable for the measurement of flows with very fast fluctuations at a point (high turbulence) and the study of flow micro structures, where there is a need to resolve small flow eddies down to the order of tenths of a mm.

  • Measurement System for Heating and Air Conditioning R&D

    ComfortSense - Dantec Dynamics A/S

    Our ComfortSense system is designed for research and development of heating and air conditioning systems requiring multi-point measurements of air velocity and temperature. The ComfortSense features omnidirectional sensors with a frequency response of 2 Hz to obtain draught measurements.A Humidity and an Operative Temperature probe are also available together with a powerful application software with graphical presentation of results including the Predicted Mean Vote (PMV) and Predicted Percentage Dissatisfied (PPD).

  • Eddy-Current Sensors

    Lion Precision

    Eddy-Current sensors are noncontact devices capable of high-resolution measurement of the position and/or change of position of any conductive target. Eddy-Current sensors are also called inductive sensors, but generally "eddy current" refers to precision displacement instruments (or nondestructive testing probes) and "inductive" refers to inexpensive proximity switches. High resolution and tolerance of dirty environments make eddy-current sensors indispensable in today's modern industrial operations.

  • High Voltage Clip for Test Leads

    Parrot Invent

    - The new Parrot clips are high voltage gripping clips for test leads and probes. High Voltage Parrot clips replace insulated alligator clips, plastic coated miniature alligator clips, small crocodile clips or large alligator clips.- Parrot Clips have a design with a new metal tube tip which is connected directly to the lead.- The tip, the hooked rod and the spring are housed in a plastic support.

  • 6TL24 Combinational Base Test Platform

    H71002400 - 6TL Engineering

    The 6TL24 is the Base platform ideal for Combinational test (ICT+FCT) in low to mid volume, high-mix electronics productions. A dual-stage pushing mechanism will allow performing both, the FCT and the ICT test, without the need of changing the test platform and with a low cost fixturing technology. To do so, the exchangeable cassette fixture must be designed with two-level probes. IN the 6TL24, the second level is reached thanks to a pneumatic actuator.

  • Energy Meters

    Rj-7600 - Laser Probe Inc.

    The Rj-7610 Single Channel Energy Meter works with a variety of probes – pyroelectric, silicon, and thermopile – to measure true energy per pulse from single-shot to 40 Hz, picojoules to Joules, UV to far-IR. Sets of 10 or 100 pulses can be statistically analyzed (mean, minimum, and maximum energies, standard deviation), and data can be transferred to computer via the IEEE-488 GPIB computer interface or using the 0-10 VDC analog outout.

  • Magnetic Permeability Meter Ferromaster

    Stefan Mayer Instruments

    Instrument for easy measurement of the relative magnetic permeability µr of feebly magnetic materials and workpieces with a permeability between 1.001 and 1.999. The permeability is measured by touching the workpiece with the probe tip and reading the result from the display. Typical applications are: non-destructive testing of materials, e. g. quality control of stainless steel, material selection for electron-/ion-beam equipment, detection of material defects induced by mechanical or thermal stress.

  • Non-Contact Mapping Life Time System

    MWR-2S-3 - HenergySolar

    The device is designed for express non-destructive contactless local measurement of non-equilibrium charge carrier effective lifetime in silicon substrates, epi-wafers and solar cells at different stages of manufacturing cycle. It can be used for incoming and outcoming inspection of silicon ingots and wafers, tuning and periodic inspection of semiconductor and solar cell technology quality. Lifetime determination is based on measuring photoconductivity decay after pulselight photo-exciting with usage of reflected microwave as a probe.

  • Monitor and Test Video Quality

    Torque Electronic Couch Potato (ECP) - torque VIDEO SYSTEMS

    The ECP is designed to monitor and test video quality of experience. This affordable, compact, palm-sized monitoring probe monitors true customer viewing experience by providing measurements from the end users’ point of view, after the STB. Scanning through available channels or navigating through interactive content menus via an external IR blaster, the ECP provides a single dashboard highlighting service quality across all channels.

  • Water Filler for Nickel-Cadmium Cells

    MasterFiller - JFM Engineering

    The MasterFiller is an instrument designed to deliver measured quantities of distilled water as required in the service of Aircraft Nickel-Cadmium batteries.· The MasterFiller consists of a microprocessor controlled pump with a level sensing probe, a keypad and display and an external 12VDC power supply (or optional battery).· The MasterFiller is part of a system comprising Intelligent Charger-Analyzers and Software for Battery Data Acquisition and Analysis, designed to improve the accuracy and efficiency of the process of testing batteries for airworthiness certification.

  • Mezzanine System

    5047 - Abaco Systems Inc

    The 5047 provides breakout of all ECM signals for debug, design validation and development. Plated through holes on the PCB allow soldering of probe wires to IO, Data, Power and Serial Identification signals. LEDs indicate presence of 3V, 5V, +12V, -12V and Ground. Elevates the ECM module by 2 mm and saves wear on the ECM carrier board connectors. Since this is a debug too there is no serial identification circuit.

  • Robotic Probing of Circuit Cards

    BCO, Inc.

    System provides reliable automatic access to test points on a printed circuit under test providing rapid and accurate diagnostic measurements. Accomplished by an automated test probe with video image capability, under control of application software running on a VXI Test System utilizing LabVIEW. A VXI Prober Interface Module (VPIM), developed to Plug and Play standards, provides interface between prober and VXI Test System.

  • Guided Wave Radar Level Transmitter

    2291 - Georg Fischer Signet

    The 2291 Guided Wave Radar level transmitter is designed for continuous level measuring of conductive or non-conductive liquids, pulps and solids. The 2291 level gauge operates based on the well-known TDR (Time Domain Reflectometry) principle. Micropulses are sent along a probe guide at the speed of light. As soon as the impulse reaches the surface of the medium, it is reflected back to the electronic module. Level distance is directly proportional to the flight time of the impulse.

Get Help