Showing results: 736 - 750 of 2820 items found.
-
Schwarzbeck Mess Elektronik
The FSHPH is a passive, single-axis H-field probe suited for non-ionizing radiation measurements. The FSHPE allows a fast and accurate safety-evaluation of the measurement environment.
-
60-981-002 -
Pickering Interfaces Ltd.
The 60-981 LXI Wired Trigger Probe provides a simple method of monitoring the LXI Wired Trigger Bus activity. It provides a through line active probe that can be used to non-intrusively monitor the waveforms of the M-LVDS drivers on all 8 channels. Each channel has two single ended outputs from the differential pair that can be subtracted by an oscilloscope to display each driver output and the differential signal.
-
Heidenhain Corp.
HEIDENHAIN offers universal, high-accuracy touch probes for machine tools, enabling exact tool measurement, edge measurement on parts, and more. Proven technologies, such as wear-free optical sensors, collision protection, and integrated cleaning blowers, make these touch probes a dependable asset for tool and part measurement. The vision systems from HEIDENHAIN can also be conveniently deployed to monitor tools for even greater process reliability.
-
Texas Co.
They are normally designated X1 and X10, although 1X and 10X are sometimes seen. The designation refers to the factor by which the impedance of the scope itelf is multiplied by the probe.The X1 probes are suitable for many low frequency applications. They offer the same input impedance of the oscilloscope which is normally 1 MΩ. However for applications where better accuracy is needed and as frequencies start to rise, other test probes are needed.
-
S.TO1 / S.TO2 -
Delta OHM S.r.L.
Fixed horizontal interchangeable temperature and humidity probes with SICRAM 2 module for active transmitters, humidity and temperature regulators series HD2717T and HD2817T.
-
TP656/1 -
Delta OHM S.r.L.
“K” Type thermocouple imemrsion probe. Tolerance according to IEC 60584-2 standard. °C max: 1000. Response time: 1 s.
-
LP471A-Uveff -
Delta OHM S.r.L.
The combined probe LP471A-UVeff measures the Total Effective Irradiance (W/m²) weighted according to the UV action curve (CEI EN 60335-2-27).
-
MPI Advanced Semiconductor Test
Every MPI manual probe systems can be configured with a variety of different holders for printed circuit boards (PCB’s) in order to provide in addition to on-wafer, versatile, convenient, and accurate Signal Integrity (SI) measurements with single-ended or differential RF probes. Measuring signals at the end of the channel for eye-patterns, deterministic jitter, distortion, TDR (Time Domain Reflectometry) impedance, cross-talk, coupling, and losses, or even S-parameters is easily accomplished.
-
Renishaw Inc.
Motorised heads enable automated, repeatable re-orientation of probes to allow access to features on all faces of the part, improving the capability of the CMM and maximising productivity.
-
Extech PQ3110 -
Extech Instruments Corporation
The Extech PQ3110 is a Clamp Probe kit for use with PQ3350 power quality analyzer. Comes with three clamps with a 30 mm (1.2 in) clamp jaw.
-
LP471P-A -
Delta OHM S.r.L.
Combined probe for measuring ILLUMINANCE (lux), with standard photopic response, and IRRADIANCE (μW/cm²) in the UVA spectral range (315…400 nm, with peak at 360 nm).
-
TP878.3 -
Delta OHM S.r.L.
Contact temperature probe for solar panel. Class B Pt100 sensor. Adhesive aluminum plate. Dimensions 10 x 30 x 5 mm.
-
LPPHOT01S -
Delta OHM S.r.L.
The transmitter LPPHOT01S converts the mV analog signal generated by the illumination probe LPPHOT01 into a digital signal suitable to be transmitted over a serial line RS485 with MODBUS-RTU protocol.
-
RHC -
KP Technology
The Relative Humidity Kelvin Probe (RHC) systems are the ideal solution for monitoring samples in a controlled atmosphere for contact potential difference (CPD)/work function (Φ) measurements.
-
SONOSCAN CFC / CF -
SONOTEC GmbH
Due to the strong damping properties of air, low frequencies in the kHz range are used in air-coupled ultrasonic testing. It is therefore all the more important that the ultrasonic transducers offer a particularly high sensitivity in order to ensure high penetration and improved resolution. We achieve this, among other things, by installing preamplifiers in the receiver probe as well as by using our own Piezocomposite Technology, which enables a flexible use of the matching materials in our CFC and CF probes.