  • Multifunctional testers

    MI 3152 EurotestXC - Metrel d.d.

    MI 3152 EurotestXC is an instrument from the new generation of Metrel’s multifunctional measuring instruments. The already well known functions like complete installation safety testing according to IEC/EN 61557 and AUTO SEQUENCE testing of TN, TT and IT earthing systems are managed by a completely new user interface based on large colour touch screen display. A wide range of functions is included: from on-line voltage monitoring, phase sequence testing, varistor testing, earth resistance measurement, illuminance measurement and TRMS current measurement up to RCD tests, line and loop impedance tests, specific earth resistance measurements as well as ISFL measurements and the IMD tests.

  • Gaussian Optics Lens Antennas

    SAG-1441544002-06-S1 - ERAVANT

    Gaussian optics lens antennas are offered with either a circular or rectangular waveguide interface. While Gaussian optics lens antennas with a rectangular waveguide interface can only support linear polarization, models with a circular waveguide interface can support various polarization types including horizontal, vertical, left-handed circular, and right-handed circular polarization for broader applications. Gaussian optics lens antennas are designed and constructed to offer high efficiency, low side lobes and a rugged mechanical configuration. A corrugated feed horn and dielectric lens allow these antennas to form well-defined Gaussian beams. Additionally, the dielectric lens provides phase error corrections and serves as a radome to protect from environmental conditions.

  • Vibrator QC System

    Accelerometer Array - Seismic Source Co.

    *24-channel input interface for DAQLink-III acquisition system (23 for accelerometers and one for True Reference)*Computes accelerometer weighted sum using input array*Controlled state of current supplies for external accelerometers*LED status indication of every accelerometer input*Differential outputs to the acquisition system*Input channel impedance of 1 Mohm*Bandwidth: 0.1 - 5000 Hz*Crosstalk: -100 dB*Phase tolerance of channels: ±0.2 deg*10 mA current supply for every accelerometer channel*Max input signal: ±10 V p-p (True Reference), ±2.8 V p-p (Accelerometer input)*Power supply: 9 - 18 V

  • Microwave Wideband PIN-TIA Receivers

    MR22 (40KHz~18GHz) - Hangzhou Huatai Optic Tech. Co., Ltd.

    MR22 series microwave wideband optical receiver, adopts High linear PIN diode and limiting amplifier, within bandwidth of 40KHz~18GHz, they are featured with excellent linearity, high responsibility and superior flatness of the RF response in both, power and phase. They provide an outstanding linearity fiber optical communication for analogue wideband microwave application. Due to avoidance of using expensive coaxial cable or wave-guide, there will be no limitation in transmission distance, which improves the signal quality and reliability of the microwave communication. They can be widely applied in microwave communication system such as remote wireless, timing and reference signal distribution, telemetry, measurement and delay line etc as well as 10Gb/s and 18Gb/s high speed communication system.

  • PCB Connectors

    Rosenberger Hochfrequenztechnik GmbH & Co. KG

    Rosenberger offers a wide range of PCB connectors, which are tailored to the high demands of industrial test applications. The product range includes many common standard RF series, e.g. SMP, WSMP, Mini-SMP, SMA, QMA, SMB, MCX or Mini-Coax, but also innovative coaxial series such as P-SMP, Longwipe-SMP, FMC or Micro-RF.For specific test & measurement applications, Rosenberger develops and produces modular connector systems for DC frequencies up to 50 GHz, solderless PCB mount connectors for ultra-high frequency applications up to 110 GHz or spring-loaded coax systems ( > 2,500 matings, pairwise phase matching 10 ps standard, different cable lengths).

  • Microwave Wideband APD-TIA Receivers

    MR12 (40KHz~18GHz) - Hangzhou Huatai Optic Tech. Co., Ltd.

    MR12 series microwave wideband optical receiver, adopts high Sensitivity APD diode and limiting amplifier, within bandwidth of 40KHz~18GHz, they are featured with excellent linearity, high responsibility and superior flatness of the RF response in both, power and phase. They provide an outstanding linearity fiber optical communication for analogue wideband microwave application. Due to avoidance of using expensive coaxial cable or wave-guide, there will be no limitation in transmission distance, which improves the signal quality and reliability of the microwave communication. They can be widely applied in microwave communication system such as remote wireless, timing and reference signal distribution, telemetry, measurement and delay line etc as well as 10Gb/s high speed communication system.

  • Relay And Protection Testing

    Ponovo Power Co., Ltd.

    As the first protection relay test set manufacturer in China, PONOVO has been always offering reliable protection relay testing equipment for customer for more than 20 years. More than 20,000 relay test kits has been supplied to users in China and other countries, including 6-phase, 3-phase, single phase relay test sets, capable of testing all kinds of protection relays, from electromagnetic relays, solid state, numerical, microcomputer relays and digital relays based on IEC61850 as well as other testings, such as, energy meter, transducer, etc. With various models with different specifications, users can definitely choose the model suitable for their testings.

  • Safety

    Chroma Systems Solutions, Inc.

    The purpose of safety testing medical electronic equipment is to be sure that a device is safe from electrical hazards to the patient and caregivers. There are a number of UL, European and Canadian standards that serve as the ruling body on how medical products will be tested, one in particular, IEC60601 (the International Electrical Safety Standard for medical electronic equipment) is experiencing “global harmonization,” meaning it has been accepted and implemented around the world. The IEC60601 standard is mainly intended for product development where safety considerations must be taken into account early in the design phase of a product, however much of it is applied to production line testing since it is the only way for a manufacturer to be sure they are shipping safe product.

  • Powermetrix Remote Manager®

    Powermetrix Systems

    Powermetrix extends the functionality of its industry leading line of handheld three phase analyzers with Powermetrix Remote Manager (PRM)®. PRM® enables wireless control of essential and various meter and meter site analysis and accuracy tests remotely. Real-time wireless transfer of testing and site data enables immediate reporting of test results. Using Bluetooth, PRM® enables seamless, remote wireless control of your Powermetrix analyzer with your secure Windows laptop or tablet, elevating your current testing and data collection capabilities. Add a higher level of safety operability with your PowerMaster® analyzer remotely with PRM®.

  • RF Ports Alignment Software

    Rohde & Schwarz GmbH & Co. KG

    With the R&S®RF Ports Alignment software together with the option R&S®SMW-K545, Rohde & Schwarz provides a standard and tailored solution for calibrating amplitude, time and phase of multi-channel SMW setups. The RF Port Alignment automatically collects the gathered correction data for the multi-channel setup using a connected vector network analyzer such as the R&S®ZNA or R&S®ZNB. Thanks to an intuitive graphical user interface the test engineer is guided through the calibration procedure step-by-step in a convenient way. With a calibrated multi-channel setup, tests of advanced systems in wireless communication or of radar receivers can be performed straightforward.

  • Electroacoustic Analysis System

    CRY6151B - CRYSOUND

    CRY6151B is a full-featured electroacoustic tester newly launched by CRY Sound. It is powerful and stable. It can measure the performance indicators of headphones (USB, Bluetooth, anti-noise), microphones (electret, MEMS, moving-coil type), headphone and microphone assemblies, receivers/headphone speakers, speakers/loudspeakers (common, Bluetooth), loudspeaker crossover devices, and other electroacoustic devices, such as sensitivity (SPL), impedance, distortion (THD), resonance frequency F0, left and right headphone balance, left and right headphone position, phase polarity, microphone current and voltage, SNR, microphone directivity, speaker's TS parameters, telephone receiving and sending loudness ratings, etc. Its test frequency range can be up to 20 Hz - 20 kHz.

  • NI-9237, 50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module

    779521-01 - NI

    50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module - The NI‑9237 includes all the signal conditioning required to power and measure up to four bridge-based sensors simultaneously. The module provides strain or load measurements with zero interchannel phase delay. It also has 60 VDC isolation and 1,000 Vrms transient isolation, providing high‑common‑mode noise rejection and increased safety. You can program the NI‑9237 for use with half-bridge and full-bridge sensors with built-in excitation. The four RJ50 jacks provide direct connectivity to most torque or load cells and offer custom cable solutions with minimal tools.

  • NI-9237, 50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module

    780264-01 - NI

    50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module - The NI‑9237 includes all the signal conditioning required to power and measure up to four bridge-based sensors simultaneously. The module provides strain or load measurements with zero interchannel phase delay. It also has 60 VDC isolation and 1,000 Vrms transient isolation, providing high‑common‑mode noise rejection and increased safety. You can program the NI‑9237 for use with half-bridge and full-bridge sensors with built-in excitation. The four RJ50 jacks provide direct connectivity to most torque or load cells and offer custom cable solutions with minimal tools.

  • NI-9237, 50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module

    780264-02 - NI

    50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module - The NI‑9237 includes all the signal conditioning required to power and measure up to four bridge-based sensors simultaneously. The module provides strain or load measurements with zero interchannel phase delay. It also has 60 VDC isolation and 1,000 Vrms transient isolation, providing high‑common‑mode noise rejection and increased safety. You can program the NI‑9237 for use with half-bridge and full-bridge sensors with built-in excitation. The four RJ50 jacks provide direct connectivity to most torque or load cells and offer custom cable solutions with minimal tools.

  • Dual Channel Bit Synchronizer for Rates up to 45 Mbps

    LS-45-DB - Lumistar Inc.

    The Lumistar LS-45-DB Dual Channel Bit Synchronizer Daughterboard provides optimal reconstruction of a serial PCM data stream that has been corrupted by noise, phase jitter, amplitude modulation, or base line variations. The all-digitaldesign assures a high performance, consistent product, with excellent reliability and long-term stability. Dual channel design can feed each channel of the LS-55-DD dual decom. The LS-45-DB also has a post D combiner that allows for optimal ratiocombining of the two input signals A unique Built-in-Test feature allows performance verification for the Bit Synchronizer to ensure the highest level of operation. Auto-test BIT is performed for a short duration on the application of power and tests more than 90% of the Bit Synchronizer components. This test verifies that power is properly applied, verifies that there are no internal bit errors, and performs other tests to ensure that the bit synchronizer is fully operational with status indication of results. Command-test BIT performs the same functions and can be initiated by the user at any time through the Lumistar software when used on Lumistar PC products. The user has the ability to generate internal pseudo-random patterns and calculate internal bit error rates with or without the injection of forced errors.Various status indicators are also available through the software. The Bit Synchronizer also contains a BER reader as well as frame sync pattern indicator.