Filter Results By:

Products

Applications

Manufacturers

Phase

the difference between two features of a waveform, measured in any of multiple manners (distance, time, angle, wavelength, etc.)

See Also: Phasing, Phase Standards, Phase Meters, Phase Angle, 3 Phase, Time


Showing results: 1141 - 1155 of 1586 items found.

  • Time Domain Sensors

    TDS - Schmid & Partner Engineering AG

    Time Domain Sensor (TDS) probes are miniaturized fully isolated active optical magnetic or electric field sensors operating in the frequency range from 10MHz to 6GHz. TDS offers unparalleled sensitivity for EM measurements resolved in the time and frequency domains while maintaining all amplitude and phase information.

  • PID Controllers

    Zurich Instruments AG

    Zurich Instruments offers PID controllers exclusively as upgrade options for lock-in amplifiers, impedance analyzers and boxcar averagers. Consequently, a number of different inputs can be chosen for the PIDs: the set of choices includes amplitude, phase, quadrature and in-phase components of demodulated signals, boxcar outputs, as well as auxiliary inputs and outputs.

  • Dielectric Fault Analyzer

    DFA100 - Doble Engineering

    The DFA100 Dielectric Fault Analyzer is a handheld survey tool used to identify and locate partial discharge, particles, and mechanical defects.With three measuring modes, continuous, phase and pulse, the DFA100 uses its acoustic emission sensor to find in-service acoustic signals produced by partial discharge and loose components.

  • 20 GHz Signal Source

    VCO Series - SignalCore, Inc.

    The SC5510A and SC5511A are VCO-based, synthesized signal sources with very low phase noise and an amplitude control of 0.01 dB throughout its -30 dBm to +15 dBm output power range. By utilizing a unique multiple phase-locked loop architecture, phase spurs are kept below -70 dBc across the entire tuning range, even at 1 Hz step resolution. Download the data sheet to see how the impressive features and specifications of these modules make them stand out when compared to other small modular synthesizers. These 20 GHz signal sources include an additional, independent RF2 channel with a tunable frequency range from 100 MHz to 3 GHz and a tuning resolution of 25 MHz. The extra channel makes the modules suitable for either single-stage RF conversion systems or dual-stage image suppression up/down converter systems. Both modules make great general-purpose laboratory signal sources where demanding low phase noise and signal purity are required. They are both ideal choices as an integrated clock source for fast DAC and ADC applications, especially those that require variable sampling rates. Full implementation instructions, GUI, driver software, and example code are provided with each module.

  • Drop Volume Tensiometer

    DVT50 - KRÜSS GmbH

    The effect of a surfactant as an emulsifier is based on the fact that it reduces the interfacial tension between phases which do not easily mix. As surfactants need a certain time to do this, the effect of an emulsifier depends on the mixing dynamics. With our Drop Volume Tensiometer – DVT50, you can measure the speed with which emulsifiers produce their effect and reduce the interfacial tension. The DVT50 spectrum ranges from very fast to very slow processes. This enables the dynamic mixing behavior as well as the stability of an emulsion at close to the quiescent state to be determined in a single measurement. The results of the measurement help to precisely optimize and dose surfactants for emulsions.

  • Earth Leakage Breaker And Residual Current Device

    IGR Series - Jaeshininfo Co. Ltd

    IGR Leakage Current Analyzer is invented as the world first, and also can measure Insulation Resistance (MO) without power cut-off. This patented instrument can analyze leakage current, and display Igr(resistive), Igc(capacitive), and Io(vector sum), Ground Insulation Resistance, and the phase angle between voltage and current. (IGR ELB) - Operates due to Igr. - Properly-operating in spite of IGC in digital era. ( Not tripping on UPS load and Harmonics and noise area) - Possible to go down Igr for safety of people and animals. - Possible to manufacture high sensitive ELB. - Possible to prevent fire from electric leakage current.

  • ECU Calibration

    Accurate Technologies Inc.

    Designing an Electronic Control Unit (ECU) is only the beginning. The features in ECUs, such as Powertrain Control Units, are quickly becoming more complex and offering more features. Thousands of variables are now provided for the engineer to modify during the in-vehicle calibration phase, and fine tuning them is as complicated as it is critical. Calibration tools significantly impact the efficiency and effectiveness of the ECU development process. These tools are typically comprised of PC-based software to perform the adjustment of the variables and an ECU hardware interface to provide the connection of the software to the controller. Teams must be able to measure and time-align relationships of inputs and outputs and make real-time modifications.

  • High Frequency Current Transformer

    HFCT Ø 140mm - Techimp HQ S.r.L

    Techimp Clamp High Frequency Current Transformer model 140 is an inductive sensor for partial discharge measurements. It is suitable for online /off line PD tests on : large diameter cables ; grounding rod bar ; etc. A TNC termination is available to connect the Clamp HFCT 140 to the TechImp PD analyzer : PDCheck , PDBase etc. The arrow indicates the requested input current (Iin) direction to get coherent output voltage (Vout) polarity respect to ground. When the sensor is installed with the arrow directed to ground, the detected voltage signal (Vout) has the same phase of the input current (Iin).

  • PCIe Direct Digital Synthesizer

    Furaxa, Inc.

    These devices provide two synchronized DDS-based RF channels on a single PCI card. With fine frequency, amplitude and phase control the Synth1000 products enable a number of advanced applications at a fraction of the cost of conventional equipment. In addition to two analog outputs the Synth1000, up to 4 separate profiles may be dynamically selected using externally supplied TTL signals for low-latency triggered operation such as PSK, FSK, and triggered sweep operation. Software support for Windows 8, 7, Vista, Windows XP and Linux is included. LabVIEW Labview source code available. For detailed specifications, please refer to the Synth1000 Manual.

  • RF Signal Generators

    Salicon Nano Technology

    As Rigol's RF first signal source, the DSG3000 series offers standard AM/FM/ØM analog modulation, as well as options for I/Q modulation and I/Q baseband output. The instrument is available with maximum frequencies of either 3 GHz or 6 GHz. Featuring a high signal purity with phase noise measuring <-110dBc/Hz@20kHz (typical) and a wide output range of -130dBm to +13dBm, the DSG3000 RF signal generator has standard pulse modulation with an on/off ratio of up to 80dB, with optional pulse train generator available. The DSG3000 series also has an amplitude accuracy of <0.5dB (typical).

  • Common Mode Chokes

    Pulse Electronics

    Common Mode Chokes, as the name implies, are designed to attenuate and filter common mode noise within an electric system.   The key parameters for a common mode choke are the current rating (to ensure the part does not overheat within the application), the impedance versus frequency (to ensure it is optimized to attenuate the desired frequencies), the isolation voltage (to ensure it meets board level requirements between the line and neutral phases) and safety isolation (to ensure it meets the safety requirements of the end-application).   It is important to remember that common mode chokes cannot saturate in the application (under normal use) as they are designed to ensure that the line and return currents are balanced.

  • Frequency Converters

    Ducommun Inc

    Ducommun's frequency converter families include waveguide detectors (FAS), passive and active multipliers (FMP and FMA), up and down converters (FUB and FDB), harmonic mixers (FDH), subharmonically pumped up and down converters (FUS and FDS) and phase detectors and single sideband modulators (FPB and FSS). These devices are offered in 7 waveguide bands to cover entire 18 to 110 GHz frequency spectrum. These converters employ high performance GaAs Schottky beamlead diodes and DLT's proprietary circuit configuration to produce superior performance, such as low conversion loss and up to full waveguide instantaneous operation bandwidth.

  • Circuit Breaker Time Interval Meter

    Crest Test Systems Pvt. Ltd.

    Measuring contact timings is useful for finding the contact bounces and non-simultaneity of contacts. This helps in finding the possible electrical or mechanical defects in the circuit breaker contacts. Timing analysis also make it possible to detect incorrect mechanical adjustments and wear phenomena of the circuit breaker by measuring the differences between the fastest and slowest phases.

  • Universal Counters

    SC-7217A / SC-7215A - IWATSU Electronic Co., Ltd.

    The SC-7217A / SC-7215A universal counters provide full capabilities including frequency, period, time interval, pulse width, phase, frequency ratio, duty cycle, event accumulation and peak voltage measuring, with simple operation. They are suitable for R&D and technical training as a basic measuring instrument as well as for production/inspection lines.

  • Semi-automatic Three-phase kWh Meter Test Bench

    SY8310 - Hong Kong Songyang Industrial Ltd.

    The new SY8310 series semi-automatic three phase energy meter test board, designed according to International Standard, is a newly developed ideal measuring equipment for energy meters. The equipment can be operated easily through test board button to preset directly all data of meter under test and test process.

Get Help