Showing results: 1501 - 1515 of 1586 items found.

  • Advanced Primary Injection Test Set

    PI-2500 - ETI Precision

    The PI-2500 is a versatile and technologically advanced primary injection tester capable of testing circuit breakers up to 2000 amperes frame size. It incorporates a low-impedance output transformer with dual secondaries to provide optimal impedance matching to a wide range of breaker sizes. High-capacity internal fan cooling allows maximum utilization of the output transformer and faster recovery after overload conditions. It is housed in a rugged aluminum frame enclosure with removable sides allowing easy access to all internal components to facilitate ease of service and maintenance. The output of the test set is controlled by means of a proven SCR controller. This provides precise initial phase angle control to reduce DC offset for inductive loads and more consistent pulse currents.

  • Design for Test

    Test Coach Corporation

    Test Coach offers Design for Test (DFT) consulting to assist customers with design review of prototype boards prior to release for production. Design for Test analysis is extremely important in ensuring that an assembly will achieve the highest possible test coverage. For ICT, this DFT will review the board to confirm that the bed-of-nails test fixture can be fabricated to test an assembly without sacrificing test coverage. As with ICT, Flying Probe benefits from DFT analysis by reviewing test point access and mechanical challenges that may affect the potential test coverage. Completing a DFT enables Test Coach to make recommendations to our customers that may be implemented on boards during the design phase which will allow for the most comprehensive coverage at time of test.

  • Sync Generator

    LT4611 - Leader Electronics Corp.

    This product is a 1U full-rack size sync signal generator that outputs analog video sync signals and audio word-clock signals for broadcast stations. The external sync signal genlock function allows synchronized operation with input signals.The genlock function has a stay-in-sync function that maintains the phase when an error occurs in the input analog video sync signal. The dual power supply unit provides redundant operation. These features make it possible to configure a highly reliable system.Further, numerous options are available to allow GPS synchronization and PTP synchronization as well as arbitrary pattern output and digital audio output using 12G-SDI, 3G-SDI, HD-SDI, and SD-SDI. These options are designed to enable the management of the optimal synchronization system for your application.

  • Automatic Asphalt Content Tester

    Atico Export

    4000g sample capacity, integrated +0.1gm accuracy weighing scale, High temperature ceramic filtration system and afterburner for accurate measurement of bitumen content in asphalt mixes. Automatic operation through user defined automatic end point detection and 24 hour start timer. User defined control of furnace chamber temperature from 200 – 650oC, Digital display and printing of test data through bright LED displays and integrated printer, Software activated mechanical door lock to prevent door from opening during test process and cutting off power from the heating elements upon opening the door. Operates on Single Phase, 220V, 50 Hz, 20 Amp and consumes less than 5000 W.

  • sbRIO-9237, Non-Enclosed, 50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module

    781028-01 - NI

    Non-Enclosed, 50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module - The sbRIO‑9237 includes all the signal conditioning required to power and measure up to four bridge-based sensors simultaneously. The module provides strain or load measurements with zero interchannel phase delay. It also has 60 VDC isolation and 1,000 Vrms transient isolation, providing high‑common‑mode noise rejection and increased safety. You can program the sbRIO‑9237 for use with half-bridge and full-bridge sensors with built-in excitation. The four RJ50 jacks provide direct connectivity to most torque or load cells and offer custom cable solutions with minimal tools. Non-enclosed modules are designed for OEM applications.

  • Electroacoustic Analysis System

    CRY6151 - CRYSOUND

    CRY6151 Electroacoustic Analysis System is a full-featured electroacoustic device tester launched by CRY Sound. It has a history of 10 years. It is powerful and stable. It can measure the performance indicators of headphones (USB, Bluetooth, common), microphones (electret, MEMS, moving-coil type), headphone and microphone assemblies, receivers/headphone speakers, speakers/loudspeakers (common, Bluetooth), communication helmets, loudspeaker crossover devices, and other electroacoustic devices, such as sensitivity (SPL), impedance, distortion (THD), resonance frequency F0, left and right headphone balance, left and right headphone position, phase polarity, microphone current and voltage, SNR, microphone directivity, speaker's TS parameters, telephone receiving and sending loudness ratings, etc. Its test frequency range can be up to 20 Hz - 20 kHz.

  • sbRIO-9237, Non-Enclosed, 50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module

    781209-01 - NI

    Non-Enclosed, 50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module - The sbRIO‑9237 includes all the signal conditioning required to power and measure up to four bridge-based sensors simultaneously. The module provides strain or load measurements with zero interchannel phase delay. It also has 60 VDC isolation and 1,000 Vrms transient isolation, providing high‑common‑mode noise rejection and increased safety. You can program the sbRIO‑9237 for use with half-bridge and full-bridge sensors with built-in excitation. The four RJ50 jacks provide direct connectivity to most torque or load cells and offer custom cable solutions with minimal tools. Non-enclosed modules are designed for OEM applications.

  • 40kw High Efficiency AC/DC Power Supply Charger 100-750VDC Charging Rectifier 100A Battery Charger

    SD750100G - Zhejiang Sandi Electric Co., Ltd

    40kw High Efficiency AC/DC Power Supply Charger 100-750VDC Charging Rectifier 100A Battery Charger is for DC battery system charging station. With three-phase non neutral conductor AC input, it has the advantages of high efficiency, high power density and low harmonic. 50-500Vdc output voltage range optional, suitable for all types of batteries.FeaturesProduct Introduction:SAND AC/DC Charger is specially developed for DC chargers module. It has high efficiency, high power factor, high power density, high reliability advantage. AC input 3 phase or single phase, DC output voltage range from 100 to 750VDC can be set, compliant with CE safety requirements, EMC standard EN61000-6-3 and EN61000-6-1 Class A, it is an advanced international level charger module.Unique function:● High efficiency over the full load range, full load efficiency greater than 95.5%● Wide output voltage range, 100-750VDC, suitable for a wide range of Lithium and lead acid battery● 5-inch LCD touch screen, easy to operate● Flexible application, charging voltage, charging current, charging time, timing charging can be set by LCD screen, easy to operateMain features:● Powerful protection, overheating, short circuit, overload, overvoltage, undervoltage, etc.● Three phase active power factor correction technology, reduces the harmonic interference to the grid● Dual DSP design, achieve the full digital control, less components means high reliability● Wide input voltage range, allows operation in most poor grid conditions● Soft start charging and soft shutdown minimize the impact on the battery.● Input, output have protective circuit breaker switch● Module adopts hot pluggable design, which is convenient for maintenance.● CAN/RS485 interface (Optional)SpecificationModel SD750100GAC input Input system Three phases + PEVoltage range 280Vac ~500VacRated voltage 440VacFrequency range 50Hz/60HzMaximum current <74AITHD (total harmonic distortion) <5%DC output Output power 40KWVoltage range 50-750Vdc ( can set)Constant power output voltage range 400Vdc-750VdcOutput current range (A) 100A ( 1~100A can set)Output current limit 1-100A continuously adjustableSteady voltage precision <±0.5%Steady current precision ≤±1% (rated range of 20% ~ 100% for output load)Load regulation rate ≤±0.5%Startup overshoot ≤±3%Peak-to-peak value noise ≤1% (200~1000V, 0~20MHz)Display Indication Light Green LED: normal operation,Yellow LED: alarm, Red LED: failureDisplay language EnglishDisplay 5’ LCD touch screenPower factor and THD Power factor ≥0.90 Full-load output power of @20%~50%≥0.98 Full-load output power of @50%~100%≥0.99 Full-load output power, input nominal voltage and frequency of @100%THD ≤5% Full-load output power of @50%~100%Protection function input overvoltage Protection Over Under Voltage automatic shutdown and restart when voltage return normalOutput overvoltage protection Over Under Voltage automatic shutdown and restart when voltage return normalOver-temperature protection Automatic shutdown. Automatic restart when the temperature return to normalShort circuit protection Automatic shutdown and lock, need power off to restart to unlockEfficiency Under Rated input voltage ≥95.2%

  • Three-Phase Transformer Demagnetizer

    DEM60C - IBEKO Power AB

    After a DC current test, such as winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remnant magnetism). It can cause various problems such as wrong diagnostics, inaccurate measurements on a transformer, inrush current at the start-up of a power transformer, or incorrect operation of protective relays due to magnetized CT cores. The best way to eliminate this source of potential problems is to use demagnetizer on the power or instrument transformer.The DEM60C is a fully automatic test instrument which performs three-phase transformer demagnetization. Transformer magnetic core demagnetization requires the application of AC current with magnitude decreasing to zero. DEM60C provides this AC current by internally changing the polarity of a controlled DC current. During the demagnetization process, the instrument supplies the current at decreasing magnitude for each step, following a proprietary algorithm. It can demagnetize single-phase and three-phase power transformers.The instrument can be connected to all three phases of a power transformer to be demagnetized, on either the primary or the secondary side. If a user selects specific vector diagrams for different types of transformers, DEM60C will run a specific demagnetization procedure for each transformer type (i.e., single phase, delta, wye/star, zig-zag.) without switching the test leads.DEM60C enables safe and efficient power transformer demagnetization. The instrument automatically regulates the injection of current and discharging energy from the inductance. During and after the operation, an intrinsically safe discharge circuit with an indicator rapidly dissipates the stored magnetic energy. The discharging circuit is independent of the power supply, which improves its reliability in case of loss of power.Test currents of up to 60 A DC enable efficient demagnetization of even the largest power transformers. Using a DV Win software, it is possible to control DEM60C externally.

  • High Performance Programmable AC Power Supply

    IT7600 Series - I-TECH Electronic Co., Ltd

    IT7600series high performance programmable AC power supplies, adopt advanced digital signal processing technology, with frequency up to 10-5000 Hz, built-inall-round power meter and large-screen oscilloscope function. Power up to 54kVA and support master-slave parallel, which can provide high-capacitysingle-phase or three-phase AC output. Some single-phase or three-phase products can be easily upgraded toAC600V (three-phase star connection downline voltage up to 1000V) output. IT7600 has built-in arbitrary waveform generator to simulate the harmonic and avariety of arbitrary waveforms output; also has strong exchange measurement and analysis functions. IT7600 can be widely used in many areas, such as newenergy, home appliances, power electronics, avionics, military, the development and application of IEC standard test and so on.

  • 8-Channel 250 MS/sec RF/IF Extreme 1/2 ATR Recorder

    Talon RTX 2590 - Pentek, Inc.

    - Rugged 1/2 ATR MIL-spec chassis- Designed to MIL-STD-810 for harsh mechanical and thermal environments- Environmentally sealed- Internally conduction-cooled- Designed to MIL-STD-461 for radiated and conducted RF- EMI power line filter- Compact and lightweight design - 22 lb (10kg)- Ideal for UAVs, military vehicles, aircraft pods and outdoor environments- RF/IF recording with eight phase coherent 250 MHz 16-bit A/Ds- Sustained real-time record rates up to 4 GB/s- QuickPac drive packs add a valuable convenience to the 1/2 ATR recorder with up to 61 TB data storage- 12 to 28 VDC power supply- Optional GPS receiver for precise time and position stamping- SystemFlow API, GUI and Signal Viewer analysis tools- Optional telnet remote connection to recorder

  • 200 MS/sec RF/IF Extreme 1/2 ATR Recorder

    Talon RTX 2586 - Pentek, Inc.

    - Rugged 1/2 ATR MIL-spec chassis for harsh mechanical and thermal environments- Environmentally sealed- Internally conduction-cooled- Fully sealed for RF emissions with EMI power line filter- MIL-STD circular connectors- Compact and lightweight design - 18 lb (8 kg)- QuickPac® drive packs allow quick removal of all data storage up to 61 TB via the front panel- Ideal for UAVs, military vehicles, aircraft pods and outdoor environments- RF/IF recording with phase coherent 200 MHz 16-bit A/Ds and DDCs- Sustained real-time record rates up to 4 GB/s- 12 to 28 VDC power supply- Optional GPS receiver for precise time and position stamping- SystemFlow GUI, API and Signal Viewer analysis tools- Optional telnet remote connection to recorder

  • Network Analyzer

    DPNA-6G AXIe - Holding Informtest

    The AXI DPNA-6G module is the world's first network analyzer in the form factor of the AXIe-1 module, as well as the first Russian device that meets the AXIe-1 standard. In the mode of the network parameters meter, the AXI DPNA-6G module measures the vector values ​​of the network parameters on two ports: transmission coefficients (S12, S21) and reflection (S11, S22). At the same time, all necessary types of calibrations are supported: one- and two-port short-circuit, XX, matched load, transmission normalization. The software supports the import of third party calibration standard parameters. In the measuring receiver mode, the module provides:*generation of a harmonic signal (frequency synthesizer);*spectrum analyzer and power level in a given band;*measuring the frequency of a known signal;*measurement of analog modulation parameters;*phase noise measurement.

  • VHF Radio Direction Finding Antennas

    Vector-Finder Series - National RF, Inc

    The Vector-Finder Series of VHF direction finding antennas provide a compact, lightweight, active antenna, suitable for use in the field with handheld transceivers and scanning radios. The mechanical design allows the sense antennas to be folded back to provide a compact unit, easily stowed or transported in any vehicle. The system interfaces with any FM receiver or transceiver via the antenna jack and the earphone jack. Several different models are available to suit your pocketbook or unique field application, all of which operate on the phase shift technique. The VF-142Q models incorporate left-right indicators as well as an audible response from which the user can determine the true direction of the radio signal. The other types utilize the audible response generated by the equipment and heard on the user’s receiver or transceiver. All models operate from a 9-volt battery.

  • Static Design Verification

    ALINT-PRO - Aldec, Inc.

    ALINT-PRO™ is a design verification solution for RTL code written in VHDL, Verilog, and SystemVerilog, which is focused on verifying coding style and naming conventions, RTL and post-synthesis simulation mismatches, smooth and optimal synthesis, correct FSM descriptions, avoiding problems on further design stages, clocks and reset tree issues, CDC, RDC, DFT, and coding for portability and reuse. The solution performs static analysis based on RTL and SDC™ source files uncovering critical design issues early in the design cycle, which in turn reduces design signoff time dramatically. Running ALINT-PRO before the RTL simulation and logic synthesis phases prevents design issues spreading into the downstream stages of design flow and reduces the number of iterations required to finish the design.