Filter Results By:

Products

Applications

Manufacturers

Phase

the difference between two features of a waveform, measured in any of multiple manners (distance, time, angle, wavelength, etc.)

See Also: Phasing, Phase Standards, Phase Meters, Phase Angle, 3 Phase, Time


Showing results: 1531 - 1545 of 1586 items found.

  • X-Band Silicon Radar Quad Core IC

    AWS-0104 - Anokiwave Inc.

    The AWS-0104 is a highly integrated silicon quad core IC intended for radar and 5G phased array applications. The device supports four radiating elements, single beam transmit, and single beam receive and includes all requisite beam steering controls for 6 bit phase and gain control. The device provides 21 dB gain during transmit mode, 21dB gain in receive mode, +15 dBm output power during transmit, and 3.4 dB NF during receive. Additional features include gain compensation over temperature, temperature reporting, and fast beam switching using eight on-chip beam weight storage registers. The device features ESD protection on all pins, operates from a +1.8V supply, and is packaged in a 56 lead 7x7 QFN for easy installation in planar phased array antennas.

  • X-Band Silicon Radar Quad Core IC

    AWS-0103 - Anokiwave Inc.

    The AWS-0103 is a highly integrated silicon quad core IC intended for radar and 5G phased array applications. The device supports four radiating elements, single beam transmit, and dual beam receive and includes all requisite beam steering controls for 6 bit phase and gain control. The device provides 21 dB gain and +15 dBm output power during transmit mode and 7 dB gain and +7 dBm IIP3 during receive mode. Additional features include gain compensation over temperature, temperature reporting, and fast beam switching using eight on-chip beam weight storage registers. The device features ESD protection on all pins, operates from a +1.8V supply, and is packaged in a 56 lead 7x7 mm QFN for easy installation in planar phased array antennas.

  • Acoustic Modem Option for Control Module

    Teledyne Marine Gavia ehf.

    ​Gavia AUVs can be fitted with the Teledyne Benthos ATM-900 Acoustic Modem. The ATM-900 Series Acoustic Telemetry Modem is the most advanced, multipath and noise tolerant, modem available. They are designed to meet both the high data rate requirements of commercial users, and the higher reliability, lower data rate requirements of the military. The modems employ two modulation techniques: phase shift keying (PSK), which provides the highest bit rate, and multiple frequency shift keying (MFSK), which provides reliability in a multipath environment, or when the modems are required to operate in a low signal-to-noise (SNR) environment. The ATM-910 Series can transmit data using PSK modulation for reception by a Gavia Modem Deckbox, but receives data using MFSK modulation only. MFSK modulation is a spread spectrum modulation process that transmits multiple tones simultaneously.

  • Primary Current Injection Sets

    R.R.Transformers & Equipments

    Protective devices such as relays, overload Coils, Circuit breakers and CTS etc. must be checked regularly to ensure that they are always ready to operate correctly, Routine current injection testing will quickly detect faulty or incorrectly adjusted protection circuits / devices & will be possible to prevent serious damage to the system. Primary injection kit is designed to operate on single phase 230/240 volts AC 50 HZ to develop smooth & continuous test current as for loading, calibrating, and testing of CTS, Bimetal Relays, Protection Relays etc. The test set gives high current output at low cost and with inherent safety. The primary current injection testing checks all parts of the protection system by injecting current down the cable / bus bars. The application of the primary current injection sets is to ascertain the current carrying capacity of any Conductor, insulator, connector or calibration of CTS / Bi-metallic relays etc.

  • 256-Element Active Antenna Innovator’s Kit

    AWA-0142 - Anokiwave Inc.

    The AWA-0142 is an active array for 5G wireless applications developed using planar antenna technology resulting in a very low profile, lightweight unit. The surface mount assembled antenna board is based on Anokiwave’s AWMF-0135 Silicon Quad Core IC and demonstrates the performance achievable using low power silicon integration and efficient antenna layout and design. Using the AWMF-0135, the antenna provides +60dBmi (1000 W) of EIRP. The electronic 2D beam steering is achieved using analog RF beam forming, with independent phase and gain control in both Tx and Rx operating modes. The AWA-0142 antenna leads the way in showing how 5G coverage can be rolled out by network operators using the mmW bands, with low power footprint and high energy efficiency, while meeting key operating specifications for data rate, latency, coverage, and reliability.

  • 5G 256-Element Active Antenna Innovator’s Kit

    AWA-0134 - Anokiwave Inc.

    The AWA-0134 is an active array for 5G wireless applications developed using planar antenna technology resulting in a very low profile, lightweight unit. The surface mount assembled antenna board is based on Anokiwave’s AWMF-0108 Silicon Quad Core IC and demonstrates the performance achievable using low power silicon integration and efficient antenna layout and design. Using the AWMF-0108, the antenna provides +60dBmi (1000 W) of EIRP. The electronic 2D beam steering is achieved using analog RF beam forming, with independent phase and gain control in both Tx and Rx operating modes. The AWA-0134 antenna leads the way in showing how 5G coverage can be rolled out by network operators using the mmW bands, with low power footprint and high energy efficiency, while meeting key operating specifications for data rate, latency, coverage, and reliability.

  • 4-CH 12-Bit 80 MS/s PCI Express Digitizer

    PCIe-9814 - ADLINK Technology Inc.

    The ADLINK PCIe-9814 is a PCI Express digitizer providing speedy, high quality data acquisition. Each of the four input channels supports up to 80MS/s sampling, with 12-bit resolution A/D converter. This allows simultaneous recording of signals on all channels with no inter channel phase delay. The extremely large on-board memory enables long recording times even at the highest sampling rates.Unlike parallel PCI buses, PCI Express slots utilize serial point-to-point connection. Each connection pair (lane) can achieve burst connection speeds of 250MB/s. The PCIe-9814, based on x4 lane slot PCI Express technology, provides a clear advantage in that direct connection of each slot allows full transfer bandwidth for each individual card. The ADLINK PCIe-9814 x4 digitizer can be used in any standard PCI Express slot, x4, x8, or x16.

  • Fully Automatic Transformer Winding Resistance Tester

    Neutronics Manufacturing Co.

    Measure DC resistance of transformers windings etc. Introduction: The NMC ''TDR'' is a high precision, new generation, light weight large output current and micro-processor controlled tester. This replaces old DC wheat stone bridge and double arm bridge for measurement of DC resistance. ''TDR'' adopts new advanced test current power supply technology, four terminal measurement, digital display of resistance value and test current. ''TDR'' is powered by 220V AC mains single phase supply. The measurements are accurate as the test current is highly stable. High automation is achieved with automatic discharge warning.Principle: The constant current generated is fed to the resistance under test through the current terminals and the voltage drop across the resistance under test is measured and displayed in ohms. A true four terminal measurement is used to eliminate the need for lead resistance compensation.

  • Nanogravimetric Measuring Instrument

    EUREKA - BioAge s.r.l.

    Eureka is a QCM / EQCM (Quartz Crystal Microbalance) nanogravimetric measuring instrument capable of mass measurements in the order of nano-grams and pico-grams. Eureka can be used with gas and liquids, the cells are made by BioAge and sold with the instrument. The tool is the most versatile among those existing on the market, with an excellent quality / price ratio. It is a portable instrument as it is powered only by the PC USB port. The instrument is extremely compact, light, reliable and designed according to the current state of microelectronics. To use Eureka simply connect it to a PC USB port and install the capture software, running in Windows ™ environment,which turns out to be very simple to use, so you can do the first experiments in a very short time. For liquid measurements Eureka is an electrochemical system, therefore, electrochemical and nanogravimetric measurements can be performed at the same time (EQCM). Eureka, if connected to a self-powered portable PC, allows to perform measurements and experiments in total freedom in environments where grid voltage is not available,or experiments that are carried out in large areas in total freedom of movement. Measurements can be made on liquids, thanks to the static cell or the flow cell, or BioAge is able to design and create customized cells according to the needs of the user, varying volumes, dimensions and materials. The instrument is very versatile because the frequency measurement range can range from 0 to 50MHz, depending on the quartz crystal used. or use a gas cell designed for gas phase analysis, BioAge is able to design and produce customized cells according to the user's needs, varying volumes, dimensions and materials.The instrument is very versatile because the frequency measurement range can range from 0 to 50MHz, depending on the quartz crystal used. or use a gas cell designed for gas phase analysis, BioAge is able to design and produce customized cells according to the user's needs, varying volumes, dimensions and materials. The instrument is very versatile because the frequency measurement range can range from 0 to 50MHz, depending on the quartz crystal used.

  • Near Field Probes 30 MHz up to 3 GHz

    RF6 set - Langer EMV-Technik GmbH

    The RF6 near field probe set consists of 2 passive magnetic field probes and 2 passive E field probes for measurements in the development phase of the E-field and magnetic field in the range from 30 MHz to 3 GHz on electronic assemblies. The probe heads of the RF6 set allow a step by step localization of interference sources of the RF magnetic field and RF-E-field on an assembly. From a larger distance the electromagnetic interference is detected by RF-R 50-1 for the magnetic field and by RF-E 02 for the E-field. The RF-B 3-2 and RF-E 10 probes with their higher resolution can more presicely detect the interference sources of the magnetic field and the E-field. Field orientation and field distribution on an electronic assembly can be detected by special guidiance of the near field probe. The near field probes are small and handy. They have a sheath current attenuation and are electrically shielded. They can be connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They do not have an internal terminating resistance.

  • Diagnosis Tool for Sercos III Networks

    Sercos Monitor - Sercos International e.V.

    The Sercos Monitor is a powerful diagnosis tool for Sercos III networks which is available for free download from the Sercos website. It allows a comprehensive and detailed analysis of data traffic in Sercos III networks. The Sercos Monitor supports the Windows XP and Windows 7 operating systems. The tool, which is based on the WinPcap interface, allows a retrospective evaluation of network records saved in pcap format, as well as real-time analysis of network traffic. The user-friendly interface and overview functions which are characteristic of Sercos III networks, such as topology, communication phases and service channel transfers, allow the analysis process to be started quickly and in a targeted manner. Experienced users also have comprehensive protocol and analysis functions available to them. Various views and filters allow an evaluation of Sercos III real-time telegrams and other Ethernet telegrams which is tailored to meet the user's requirements. If required, the functionality of the Sercos Monitor can also be expanded with user-specific plug-ins.

  • Rack-Mounted Timing Systems

    CommSync II Family - FEI-Zyfer Inc.

    The CommSync II family of modular systems provide GPS time and frequency outputs to meet your synchronization requirements. All systems include support for multiple input and output modules including 1PPS, IRIG, HAVE QUICK, PTTI, IEEE-1588 PTPv2, low phase noise 1, 5, and 10 MHz sine wave as well as custom outputs.These systems are available with military SAASM MPE-S GB-GRAM, SAASM Force 22E MRU or civilian C/A GPS receivers. Rubidium or OCXO oscillators provide for excellent holdover performance in the event of failure of the reference inputs. In addition, they may be configured as Distribution Time and Frequency (DTF) systems that are synchronized by an external reference. Dual Redundant systems (CommSync II & CommSync II-D) may be configured with two GPS Time & Frequency (GTF) modules and two power supply modules (AC and/or DC power) for redundancy with uninterrupted automatic switchover.

  • Harmonic/Flicker Analyzer for IEC61000-3-2/3/11/12, IEC61000-4/7/15

    KHA3000 - Kikusui Electronics Corp.

    KHA3000, in addition to the complied standards and features of the KHA1000 (dedicated for single phase), is equipped for the harmonic and flicker compliance test exceeding 16A of the single-phase and three-phase equipment. With this unit alone, you can take highly accurate simultaneous three-phase measurements up to 40A/phase*. Furthermore, the KHA series is compliant with two measurement technique standards, the existing and the latest versions, so you can simply select to take measurements for the latest standard including interharmonics and for the conventional integral multiple harmonics without using any other device. In addition to the real-time display that can be used like an oscilloscope and FFT analyzer, the unit offers the real-time judgment of compliance with standards. Using this unit alone, you can judge test results and prepare result reports without the use of a PC. On top of that, you can easily set up a test system by combining KHA3000 with an AC power supply (PCR-LA Series) and a line impedance network (LIN40MA-PCR-L).

  • Semi-Rigid Assemblies

    Teledyne Defense Electronics Storm Microwave

    Storm Products has been producing high performance semi-rigid interconnects for over 20 years for a variety of markets, including: defense, telecom, wireless and test & measurement. Experienced in:- Cable sizes from 0.034" to 0.500"- Solid PTFE dielectric and high performance tape wrapped products- Wide variety of standard connector styles: MCX, SMA, SMB, SMC, TNC, N, 7/16, SC, and HN- Years of experience on blindmate connector styles: OSP GPO, GPPO, and GMSSpecialized experience in:- Applications where phase stability is critical- low intermod interconnects- High power designsManufacturing equipment:- Automated bending equipment and optical comparators - Programmable thermal chambers for pre-conditioning formed cables- Specialized assembly and soldering equipment for high volume applications- Automated network analyzers through 50GhzDue to the custom nature of formed semi-rigid cable assemblies, additional information is required before providing a quotation for your requirement.

  • NI-9244, 400 Vrms L-N, 800 Vrms L-L, 50 kS/s/ch, 24-Bit, 3-Phase C Series Voltage Input Module

    783106-01 - NI

    400 Vrms L-N, 800 Vrms L-L, 50 kS/s/ch, 24-Bit, 3-Phase C Series Voltage Input Module - The NI‑9244 performs single-ended analog input. The wide measurement range makes it ideal for high-voltage measurement applications such as phasor measurements, power metering, power quality monitoring, industrial machinery, and motor test. You can also perform transient and harmonic analysis with high-speed simultaneous sampling. The NI‑9244 offers three channels, so you can connect single‑ or three‑phase measurement configurations such as WYE and delta. You can incorporate the NI‑9244 into systems to meet standards such as IEC 61010‑1, C37.90 and C37.60, IEC 60255‑22‑(1:7), IEC 60255‑1, C37.188 Class M and P, EMC section of IEC 60870, EMC sections of IEC 61850, IEC 61000‑4‑30 Class S, and IEC 61000‑4‑7.

Get Help