Filter Results By:

Products

Applications

Manufacturers

Phase

the difference between two features of a waveform, measured in any of multiple manners (distance, time, angle, wavelength, etc.)

See Also: Phasing, Phase Standards, Phase Meters, Phase Angle, 3 Phase, Time


Showing results: 1021 - 1035 of 1586 items found.

  • Scopes

    SmartView Duo 4K - Blackmagic Design Pty. Ltd.

    The SmartScope Duo 4K model includes built in waveform monitoring when you need to analyze image quality more accurately than simply looking at the picture! You get seven of the most popular scopes most widely used in broadcast and post production facilities. Scope displays include waveform, vectorscope, RGB parade, YUV parade, histogram, audio phase and level scopes, and of course you can simply select to view the video itself!

  • Simultaneous Sampling A/D Converters

    Analog Devices Inc.

    Analog Devices simultaneous sampling precision A/D converters offer two to eight discrete ADCs in a single package, allow two to 12 channels, and span resolutions from kSPS to 5 MSPS. Providing the industry-leading noise, linearity, and dynamic range performance, ADI has a simultaneous precision converter to meet your speed, power, and size needs. Simultaneous sampling ADCs enable users to convert multiple signals concurrently and preserve phase information.

  • Relay Test Set Type SP-I

    Supreme Instrument Laboratories

    Supreme make relay testing set is designed for site testing of protective relays which simulate in common fault conditions under which a protective relay will be called into positive function. Periodic field testing is the best way of ensuring the integrity of the protective relays. We offer our relay testing set with specific testing capacity to suit different group of protective relays. The testing set operates on single phase 230 V, A.C. 50Hz. Supply.

  • Switch Amp

    Teledyne RF & Microwave

    One of many potential designs, Teledyne RF & Microwave's switched amplifier covers 100 to 2000 MHz, providing 18 dB gain, phase matched to within ±1.0 degree. The primary RF input and a secondary calibration signal input are switched, then amplified, and split to two outputs. Gain balance between any of the two outputs is ± 0.5 dB. Output power at 1 dB compression is +14 dBm and input/output VSWR is 2.0:1 maximum.

  • Highly Accelerated Life Testing (HALT)

    Eurofins E&E

    Quickly validate reliability and identify manufacturing defects that could cause product failures in the field with MET’s Highly Accelerated Life Test (HALT)HALT technique uses a combination of accelerated stresses to expose product flaws early in the design and manufacturing stages, which improves product reliability and customer confidence inherent to the design and fabrication process of a new product as well as during the production phase to find manufacturing defects that could cause product failures in the field.

  • High Accuracy AC Reference Source

    515 - Clarke-Hess Communications Research

    The Model 515 High Accuracy AC Reference Generator fills a need for a relatively low cost and practical solution for supplying a reference excitation to typical LVDT and Synchro/Resolver transducers. The Model 515 has built-in load sensing which, in effect, yields "zero" output impedance and virtually eliminates the effects of fluctuating output loads. With up to 15 VA of output into loads with as much as 80 of phase shift, the Model 515 is ideally suited to driving inductive loads.

  • Universal Clamp Tester

    M-310 - MULTI MEASURING INSTRUMENTS Co., Ltd.

    *The unique U type CT enabled to measure the load current of single or three phase cable without separating the cable to the wires.*Leakage current measurements with least affection from the external magnetic field.*Wide current measurements.(AC0.01mA-300A)

  • Multi-function Tester

    MFT5010 - Summit

    It can be used to test insulation resistance, continuity, loop impedance and RCCB, earth resistance tester, five major test requirement in the electrical testing industry. Phase indicator. Can check a wide range of 3-Phase Power source from 110V to 600V

  • Radio Frequency Cable Tester

    RFCT - Textron Systems

    Textron Systems’ Radio Frequency Cable Tester (RFCT) allows for on-site testing and maintenance for radio frequency (RF) transmission paths within a platform. Using preconfigured databases of sweep parameters and pass/fail criteria, the RFCT quickly determines the status of installed RF cables. The RFCT checks each cable’s performance characteristics to include voltage standing wave ratio (VSWR), insertion loss (IL), phase and phase matching. If a cable fails a test, the RFCT automatically determines the distance-to-fault (DTF). With its intuitive touchscreen-based user interface and lightweight, ruggedized packaging, the RFCT is the gold standard for operational-level RF cable testing.

  • Semi-Rigid Cable, 3.5 Mm (Test Port) To 3.5 Mm

    85131G - Keysight Technologies

    The Keysight 85131G is a 53 cm (21 in) long1 semi-rigid cable with a 3.5 mm female2 to 3.5 mm male connector. Cable frequency range is dc to 26.5 GHz with a return loss of 16 dB or better. Insertion loss is 0.3 * sqrt (f) + 0.2 dB (where f is frequency is GHz) for the test port connector, and 1.8 dB at maximum frequency for the device connector. Phase stability of semi-rigid/flexible cables is characterized with a 90 degree bend using a 4 inch radius. Stability1 of the Keysight 85131G is 0.06 dB and phase is 0.16o * f + 0.5o (where f is frequency in GHz).

  • Flexible Cable Set, 3.5 Mm (Test Port) To 7 Mm

    85132F - Keysight Technologies

    The Keysight 85132F is a 62.9 cm (24.75 in) long¹ flexible cable set composed of two 3.5 mm female² to 7 mm connectors. Cable frequency range is dc to 18 GHz with a return loss greater than or equal to 17 dB. Insertion loss is 0.25 * sqrt(f) + 0.2, where f is frequency in GHz, for the test port connector and device connector. Phase stability of semi-rigid/flexible cables is specified with a 90 degree bend using a 4 to 3 inch radius. Stability¹ of the Keysight 85132F is less than 0.12 dB and phase is 0.13 * f + 0.5, where f is frequency in GHz.

  • Cross Flow Cell

    ALS Co., Ltd

    Working electrodes for flow cell are mounted on blocks of PEEK. This resin protects the electrodes from external noise and allows researchers to utilize them regardless the content of mobile phase of HPLC because of their hard, organic solvent-resistance. Glassy carbon is usually chosen for the redox reaction study on liquid chromatography. Platinum, Gold, Carbon paste and Nickel electrodes are utilized for special purposes. Thin Layer Cell has been used as a electrode for research such as flow injection analysis (FIA) and the HPLC.

  • Dual 10th Order Lowpass Filter

    64-VBF - Viewpoint Systems, Inc

    The 64-VBF 10th order Lowpass Filter is a dual channel filter with independent switch settable Cutoff Frequency (Fc). The filter has a linear phase DC accurate root raised cosine response. The unit’s differential inputs are built to withstand high DC over-voltages up to ±50 VDC and greater than ±100 V transients. Gain of the unit is 1 allowing for minimal insertion issues. The output can drive a high speed DAQ multiplexer with its fast settle and capacitive drive capability.

  • Get Flexible, Get FlexiFLASH

    LatticeXP2 - Lattice Semiconductor

    *Up to 885 Kbits sysMEM™ embedded block RAM and up to 83 Kbits distributed RAM*sysCLOCK™ PLLs up to four analog PLLs per device that enable clock multiply, divide and phase shifting*Three to eight sysDSP blocks for high performance multiply and accumulate.*Pre-engineered source synchronous IOs for DDR/DDR2 up to 200 MHz and 7:1 LVDS interface support up to 600 Mbps*Available in csBGA, TQFP, PQFP and BGA packaging

  • Handheld Gauge for Nondestructive Coating Thickness Measurement

    PHASCOPE PMP10 DUPLEX - Helmut Fischer AG

    Handheld gauge for rapid and precise measurement of duplex-coatings (for the simultaneous measurement of lacquer and zinc or of lacquer/Al)Probe ESG20 uses measuring principles according DIN EN ISO 21968 (phase sensitive eddy current); DIN EN ISO 2178 (magnetic induction); DIN EN ISO 2360 (amplitude eddy current).Delivery with PC software FISCHER DataCenter with the following functionality: Transferring and archiving measurement data, comprehensive statistical and graphical evaluations, easy creation and printing of inspection reports

Get Help