Showing results: 961 - 975 of 1587 items found.
-
E1709A -
Keysight Technologies
The measurement signal frequency changes as the stage velocity changes. The Keysight E1709A ensures minimal phase processing errors due to frequency changes. The receiver also provides immunity to errors induced by changes in measurement signal power that occur due to small pitch, roll and yaw movements during stage motion. These features help provide the most accurate measurements under system motion.
-
Model 7890 -
Pentek, Inc.
Simultaneous synthesis of up to five different clocks, Eight SMC clock outputs, Ideal for A/D and D/A converter clock sources, Typical phase noise: -125 dBc/Hz @ 1 kHz offset
-
Caltest 10 -
Calmet Smart Calibration Devices
Single phase portable electricity meters tester class 0.5% powered from tested circuit with load force possibility apart from tested object. There is no need to disconnect the users during measurement
-
Calport 100 Plus -
Calmet Smart Calibration Devices
Three phase instrument transformers and electricity meters tester class 0.1 or 0.2. It makes possible CT and PT testing on site or in the laboratory. We recommend a new replacement - TE30 Working Standard
-
MPI-525 -
Sonel S.A.
Possible measurementsShort-circuit loop measurement:*impedance measurement with 23 A current (44 A phase-to-phase) - short-circuit resistor R=10,*measurement range: 95...440 V, frequency 45...65 Hz,Short-circuit loop measurement with resolution 0,01, in distribution network without tiggering RCD (In30 mA):*automatic calculation of short-circuit, detection of phase voltage and phase-to-phase voltage,*additional UNI-Schuko plug for automatic measurement, AGT adapter for 3 phase network measurement.Testing of general and selective RCD with the rated differential current of 10,30,100,300,500 and 1000 mA. (Type AC, A and B).Measurement of insulation resistance:*with test voltage 250 V, 500 V, 1000 V, 2500 V,*measurement range up to 10G,*automatic discharging after measurement,*automatic measurement of all resistences in 3,4,5-wire cables using optional adapter AUTO-ISO,*acoustic signals in 5 sec intervals for insulation resistance characteristic,*elapsing T1, T2, T3 times (0...600 s) form measurement of absorption coefficients (DAR, PI or Ab1, Ab2)*safety measurement - protection against overvoltage.Measurement of earthing resistance.Bi-directional testing of PE wire continuity using 200 mA current.*Autocalibration of test leads.
-
M151 -
Clarke-Hess Communications Research
The Model M151 is a stable high current calibrator up to 120 A. Basic accuracy is 0.035 %. It can be controlled viaRS232 or GPIB interface. The Model 151 can function in a simulated amplifier mode to increase the current capabilityof any multifunction calibrator. It is suitable for power meter calibration because it can be synchronized with the inputsignal not only in amplitude but also in frequency and phase. The current terminals are isolated up to 450 Vpk againstcase (protective earth).
-
TA Instruments
Differential Scanning Calorimeters (DSC) measure temperatures and heat flows associated with thermal transitions in a material. Common usage includes investigation, selection, comparison and end-use performance evaluation of materials in research, quality control and production applications. Properties measured by TA Instruments’ DSC techniques include glass transitions, “cold” crystallization, phase changes, melting, crystallization, product stability, cure / cure kinetics, and oxidative stability.
-
2575 -
PCB Piezotronics, Inc.
Performance:Nominal Microphone Diameter1"1" Frequency Response: Characteristic (at 0 incidence) Random IncidenceRandom Incidence Open Circuit Sensitivity: 45 mV/Pa Resonant Frequency (90 Phase Shift)8000 Hz8000 Hz[1] Inherent Noise<10 dB(A) re 20 Pa<10 dBTemperature Range (Operating)TBD FTBD C Humidity Coefficient of Sensitivity (0 to 95%, non-condensing)0.001 dB/%RH
-
Crystal instruments
Real Time Digital Filters can be used to filter a measured signal in real time. Filter characteristics can be defined by the user to meet the requirements of a specific application. Real-time digital filters are applied in the data conditioning phase. The filters are designed with a graphic design tool and then uploaded to the front-end for real-time calculation. The graphic design tool defines the filter performance vertical axis with a dB scale. The horizontal axis is defined as relative frequency.
-
SICK Sensor Intelligence
With Safexpert®, SICK supports you with a thoroughly engineered solution for the demanding process of CE marking. Designers and managers will appreciate the systematic processes of this TÜV-certified software, with which it guides users through all the phases of CE marking, from risk assessment to the management of standards and documents. Safexpert helps designers to plan their path through the Machinery Directive transparently and logically, and then guides them efficiently along that path.
-
CPCI385 -
AcQ Inducom
The CPCI385 Universal Timer/Counter CompactPCI card is an ideal solution for automated test and measurement applications. The CPCI385 features two timer/counter inputs. Both inputs have an coaxial connector for the input range of +/- 10 V and high-voltage pins for the input range of +/- 300 V. The coupling of the inputs is either AC or DC. The CPCI385 provides 6 measurement functions: frequency, high-time, low-time, period, counter and phase measurements.
-
PCI385 -
AcQ Inducom
The PCI385 Universal Timer Counter PCI card is an ideal solution for automated test and measurement applications. The PCI385 features two timer/counter inputs. Both inputs have a coaxial connector for the input range of +/- 10 V and high-voltage pins for the input range of +/- 300 V. The coupling of the inputs is either AC or DC. The PCI385 provides 6 measurement functions: frequency, high-time, low-time, period, counter and phase measurements.
-
VME385 -
AcQ Inducom
The VME385 Universal/Timer Controller VMEbus board is an ideal solution for automated test and measurement applications. The VME385 features eight timer/counter inputs, all inputs have an coaxial connector for the input range of +/- 10 V and high-voltage pins for the input range of +/- 300 V. The coupling of the inputs is either AC or DC. The VME385 provides 6 measurement functions: frequency, high-time, low-time, period, counter and phase measurements.
-
Naprotek, LLC.
The SemiGen SBL 2000 series Beam Lead PIN Diodes feature fast switching speeds at both low capacitance and resistance. Beam Lead PIN Diodes have high levels of mechanical strength and stability during assembly. These diodes are suitable for microstrip or stripline circuits as well as circuits requiring high isolation from a series of mounted diodes such as multi-throw switches, phase shifters, attenuators and modulators.
-
BF-3200/MI-5420A/BF-0310 -
Ono Sokki
Beam Forming is one of the sound visualization techniques that obtains the sound pressure distribution using the phase differece information from the sound source to the microphone, and makes it visualized with the color map.This technique requires a lot of microphones to cover a wide area and generally tends to increase the size of the system. By this Beam Forming system, Ono sokki achieved real time sound source visualization with just 4 microphones.