Showing results: 406 - 420 of 1454 items found.
-
NUL-230 -
Neulog
There are different wavelengths of ultra violet light. The UVB wavelength range is 280-320 nm, which is 2% of the total UV radiation. The UVB radiation affects the vitamin generation in the human body, the immune suppression, skin cancer and cataract. The intensity of this light is measured in mW/m2 (milliwatt per square meter).
-
Quest Engineering Solutions
Quest Engineering Solutions has the capability to perform IPX Water (Intrusion Protection) testing per numerous IEC standards, including IEC 60529. This testing is designed as a means to verify that the products' internal components are adequately sealed and protected from the intrusion of foreign objects, liquids, and fine particles.
-
TDS -
Dwyer Instruments Inc.
Take precise measurements of total dissolved solids with Series TDS. Lightweight and compact, these testers are ideal for field testing of TDS concentrations. Large easy-to-read LCD displays the full scale readout in ppm (parts per million), no additional calculations are required to obtain actual test values
-
Annie-USB -
New Forest Electronics
A top-quality 8-channel PC-based logic analyser with probably the highest specifications in its class, this Janatek product is excellent value for money. It captures data at a maximum rate of 500MHz, has a buffer depth of up to 1 Meg samples per channel, and incorporates an 8-bit pattern generator to aid debugging.
-
SprintIR®-6S -
Gas Sensing Solutions Ltd.
The SprintIR®-6S is part of a range of CO2 sensors designed to deliver unprecedented high-speed measurement capability. The SprintIR®-6S will take up to 20 readings per second, making it ideal for applications that require individual measurements at high repetition rates or where the CO₂ concentration is changing rapidly.
-
SprintIR®-W -
Gas Sensing Solutions Ltd.
The SprintIR®-W is part of a range of CO₂ sensors designed to deliver unprecedented high-speed measurement capability. The SprintIR®-W will take up to 20 readings per second, making it ideal for applications that require individual measurements at high repetition rates or where the CO₂ concentration is changing rapidly.
-
TRENDnet, Inc.
8 x Gigabit PoE+ ports64W PoE power budgetEasy-to-use web-based management interfaceSupports LACP, RSTP, VLAN, QoS, and IGMP SnoopingVoice VLAN for VoIP applicationsBandwidth control per port16Gbps switching capacityIEEE 802.1p CoS with queue scheduling supportCompact fanless designWall mountable metal housing
-
AMETEK Sensors, Test & Calibration
Our logging software works along with our XP2i gauges and ASM multi-scanners to create digital records of your tests. With the DataLoggerXP, you can record average or live pressure, as quick as once per second. Save the data files directly into industry standard spreadsheets, or as comma separated text files.
-
LRT 2000L -
Korima, Inc.
*Travel: 6" x 6"*Laser : Fiber Laser Ytterbium 1064 nm*Kerf: 30 to 80 micron Adjustable*Pulse width : 80 nano second*Rap Rate: 1 to 1 million Pulse Per Second*Average Power: 20 watts*Target: Electric crosshair on monitor
-
HMP4000 -
Rohde & Schwarz GmbH & Co. KG
The R&S®HMP DC Power supplies are primarily designed for industrial use. With three or four output channels and up to 10 A output current per channel, these rugged instruments are ideal for a wide variety of applications. They offer high efficiency with low residual ripple and many protection functions.
-
DeltaTRAK
New "Auto-calibration" featureNeedle probe thermometer provides fastest response timeSmall diameter needle probe ideal for measuring temperature of 'thin mass' food such as meat patties, chicken, and fish fillets per FDA Code 4-302.12(B)Sealed unibody construction and RoHS compliantIP56 waterproof & grease resistant
-
ROM-Elektronik GmbH
Higher than the natural ambient/background radiation, it originates from building materials or is inhomogeneous at geological faults and underground watercourses. It causes cell damage (tumors), cell death, etc. Radioactivity (=ionizing radiation) is measured in sieverts per hour (Sv/h) or simply as a count rate (pulses/second [Ips] or pulses/minute [Ipm]).
-
RoBAT RCI -
RoBAT Ltd.
*TDR & TDT, Measurement Capabilities*Impedance, Skew, Backdrill measurements*Automated Optical Inspection*DC Electrical Test*Now available with 4 heads*24 port (1 port per channel) TDR/TDT unit*Future capabilities – Fully automated VNA test (4 port S-Parameter Measurement)
-
SQM-LU-DL -
Unihedron
A USB enabled data-logging light meter for night-time sky brightness monitoring! An affordable meter for continual, connected or autonomous data-logging to measure sky brightness for astronomers and light pollution investigators. The "Sky Quality Meter - LU-DL" (SQM-LU-DL) measures the brightness of the night sky in magnitudes per square arcsecond.
-
Dimension FastScan Bio -
Bruker Optics
The Dimension FastScan Bio Atomic Force Microscope (AFM) breaks longstanding barriers to provide routine high-resolution research of biological dynamics, with temporal resolution up to 3 frames per second for live sample observations. Furthermore, it does this while making the AFM easier to use than ever before.