Showing results: 286 - 300 of 1454 items found.
-
VPX3-4935 -
Curtiss-Wright Defense Solutions
The VPX3-4935 delivers incredible processing power from its NVIDIA Quadro Turing TU104 GPU, providing an impressive 3072 CUDA cores for parallel processing and a 50% improvement in performance per CUDA core compared to the previous Pascal generation.
-
XMC-WMUX -
Alta Data Technologies LLC
Alta Data Technologies’ XMC-WMUX interface module (PCI Express Mezzanine Card for Carriers and Single Board Computers or Carriers) is a single or dual-channel (A-B Redundant = 4 Busses per Channel/Wings) WMUX card supported by the latest software technologies.
-
5362 -
Abaco Systems Inc
ECM P/N 5362 provides eight channels of LVDS I/O with fixed 100 ohm termination. Speeds are up to 200M bits per second. All channels power up as inputs. Software can then enable outputs on a channel by channel basis.
-
PA202X-075-078 -
MISCO Refractometer
Measure Sodium Chloride specific gravity and salinity, in parts per thousand, instantly and accurately with the MISCO Palm Abbe digital handheld refractometer. A refractometer is faster and much more capable of accurately determining specific gravity and concentration compared to hydrometers.
-
ZAP MULTIRUN -
ZapTest, Inc.
The ZAP MULTIRUN allows parallel or sequential execution of the same script on multiple work stations and mobile devices. Using ZAP MULTIRUN test automation teams expedite time to execution multiplied by number of devices per given test runs.
-
Neutronics Manufacturing Co.
Oil Test is an equipment designed to test the dielectric strength of Insulating Oils as per relevant specifications vis. IS 6972. It is a useful equipment for Transformer / Switch Gear manufacturing units. Oil fettering agencies, repair shop and electrical maintenance departments.
-
A.H.Systems, Inc.
A.H. Systems' designs, manufactures and delivers high performance Loop Antennas for a wide range of magnetic field testing. Whether used in a set to measure shielding effectiveness per MIL-STD 285 and NSA 65-6 or individually to satisfy specific requirements,
-
N1046A -
Keysight Technologies
75 GHz, 85 GHz or > 100 GHz maximum available bandwidth (selectable option, upgradable)1, 2 or 4 channels per module User-selectable bandwidth settings starting at 60 GHz Electrical inputs: 1 mm female
-
LT-4203A -
Lambient Technologies
The LT-4203A Parallel Plate Dielectric Test Cell is designed for measuring the AC loss characteristics and permittivity of solid laminates and panels per ASTM Standard D150‑98, and implements the guarded electrode (three terminal) measurement preferred as the referee method.
-
ProDAQ 5821 -
Bustec Ltd.
The ProDAQ 5821 series of Signal Conditioning Cards is designed to interface with a variety of sensors, principally RTDs, Thermistors, Cryogenic Diodes and Voltage type sensors. Each version of the 5821 provides the capability of precise 4-wire measurement. In order to achieve this, a precise 500μA constant current source is provided per channel. The current source can be disabled on a per channel basis and is monitored to ensure that current is flowing. The value of the output current is stored on-board after calibration. In order to achieve the highest accuracy the output current may be automatically calibrated 'on-the-fly' using the ProDAQ 3416 24-bit Sigma-Delta ADC card and an on-board precision resistor.
-
ARAMIS SRX -
GOM GmbH
The new ARAMIS SRX is a 3D measurement system for dynamic evaluation of 3D coordinates, 3D displacement and surface strain. It comprises the latest camera technology including 12-megapixel cameras. Capturing up to 2000 images per second, the sensor is especially designed for rapid testing applications. It comes with an additional setup for crash applications providing an image acquisition rate of 1000 images per second in HD format. With the combination of high resolution and high speed, the ARAMIS SRX sensor is perfectly suited to high-end applications. The sensor is designed for high stability, process reliability and user-friendliness, which is why it is primarily used in industrial environments and applications.
-
Neff Instrument Corporation
This type of system can be designed with benefits of both the multiplexed amplifier-per-channel and transient recorder systems. Benefits of the non-multiplexed amplifer-per-channel system include: High Sampling Rates: With an ADC per channel, the sampling rate is not encumbered with considerations such as multiplexing and post-amplifier settling time.Superior Filtering: With an ADC per channel, digital filtering can be used to augment analog filtering to achieve better anti-aliasing performance with much lower effective sampling rates.Superior Phase Matching: Digital filtering provides much steeper, more predictable rolloff rates and phase characteristics than analog filtering with greater stability with time and temperature changes at lower cost.
-
Chroma ATE Inc.
A high-density 100MHz PXIe digital IO card designed for characterizing, validating, and testing a variety of digital and mixed-signal ICs. Each IO card consists of a Sequencer Pattern Generator (SQPG) and 32 channels of full ATE-like features. The 33010 IO card is expandable up to 256 channels. Some unique features of the 33010 include an on-board SQPG, per pin timing/levels/ PMU/TFMU, multiple time domains, and multithreaded testing for complex IC testing. Each channel is also equipped with 64M vector memory, 16 timing sets with on-the-fly timing change, and per pin timing and frequency measurements up to 400 MHz.
-
783868-01 -
NI
24-Bit, 32-Channel, 51.2 kS/s, 42 V, PXI Analog Input Module—The PXIe‑4305 is a filtered analog input module for higher voltage measurements. The module offers the ability to select a digital filter per channel to provide extra filtering performance. You also can operate up to four different sample rates and triggering configurations concurrently to ensure you measure every sensor as needed. The module has an A/D converter per channel to enable a simultaneous sample rate at the maximum sample rate across the input range. The included NI‑DAQmx driver simplifies hardware configuration and measurement.
-
783867-01 -
NI
24-Bit, 32-Channel, 5 kS/s, 42 V, PXI Analog Input Module—The PXIe‑4304 is a filtered analog input module for higher voltage measurements. The module offers the ability to select a digital filter per channel to provide extra filtering performance. You also can operate up to four different sample rates and triggering configurations concurrently to ensure you measure every sensor as needed. The module has an A/D converter per channel to enable a simultaneous sample rate at the maximum sample rate across the input range. The included NI‑DAQmx driver simplifies hardware configuration and measurement.