Showing results: 1096 - 1110 of 1454 items found.
-
DWTT -
Qualitest International Inc.
Since the introduction of the Drop Weight Tear Tester - DWTT, materials have moved on. In particular, demands for high operating pressures of line-pipes and larger diameters have driven the development of higher strength steels. Forty years ago the work that led to the drop weight tear test was done on X52 steel (360MPa yield strength). Improvements in thermo-mechanical processing has yielded improvements of approximately 10,000psi per decade, to the point where the state of the art is now X100 steels, and the use of X120 steels is being considered.
-
HSS-8324-DSP -
Conduant Corporation
The Conduant HSS-8324 FPGA board provides a user programmable hardware platform that is able to sustain full-duplex high-bandwidth transfers through its 8-lane Gen3 PCI Express interface and its two 12-lane HSS interfaces while performing complex calculations. The PCIe interface provides a theoretical maximum throughput of 8 GBps (simultaneous in and out) while each HSS port (12 lanes up to 16 Gbps per lane) supports a full duplex transfer at theoretical rates over 190 Gbps.
-
HSS-8324-DSP -
Conduant Corporation
The Conduant HSS-8324 FPGA board provides a user programmable hardware platform that is able to sustain full-duplex high-bandwidth transfers through its 8-lane Gen3 PXI Express (PXIe) interface and its two 12-lane HSS interfaces while performing complex calculations. The PXIe interface provides a theoretical maximum throughput of 8 GBps (simultaneous in and out) while each HSS port (12 lanes up to 16 Gbps per lane) supports a full duplex transfer at theoretical rates over 190 Gbps.
-
781397-01 -
NI
±10 V, 500 kS/s/ch, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The NI‑9222 performs differential analog input. This module is well suited for applications such as ballistics, impact, and blast wave testing. The NI‑9222 can sample at the maximum sample rate per channel while the module next to it samples at a much slower rate, which is ideal for mixed-measurement test systems. There are two connector options for the NI‑9222: a 10‑position screw terminal or a 25‑pin D‑SUB connector.
-
783283-01 -
NI
±10 V, 500 kS/s/ch, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The NI‑9222 performs differential analog input. This module is well suited for applications such as ballistics, impact, and blast wave testing. The NI‑9222 can sample at the maximum sample rate per channel while the module next to it samples at a much slower rate, which is ideal for mixed-measurement test systems. There are two connector options for the NI‑9222: a 10‑position screw terminal or a 25‑pin D‑SUB connector.
-
785480-01 -
NI
Non-Enclosed, ±10 V, 1 MS/s, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The sbRIO-9223 performs differential analog input. This module is well suited for applications such as ballistics, impact, and blast wave testing. The sbRIO-92233 can sample at the maximum sample rate per channel while the module next to it samples at a much slower rate, which is ideal for mixed-measurement test systems. There are two connector options for the sbRIO-9223: a 10‑position screw terminal or a 25‑pin D‑SUB connector.
-
784278-01 -
NI
24-Bit, 6-Channel, 1.25 MS/s/ch PXI Analog Input Module—The PXIe‑4481 is an analog input module for higher bandwidth voltage measurements. The module offers analog and digital filtering for accurate frequency domain measurements. You also can select from four gain settings to configure your input range. For measuring sudden changes, such as high speed blast and pressure events, the PXIe-4481 can sample up to 20 MS/s per channel in time domain mode. The included NI-DAQmx driver simplifies hardware configuration and measurement.
-
M9120A -
Keysight Technologies
The M9120A high-density matrix offers higher voltage switching of multiple channels in a single instance. Any row can be connected to any column, making it ideal for routing instrument signals to the device under test. This 2-wire switch matrix provides the durable armature switches allowing multiple channels to be connected at one time, up to 60W per channel. The 4-wire wide bus can be used to route signals between test instruments and the device under test. Choose from the durable connector block or standard cable connections.
-
ALPHI Technology Corporation
The CPCI-AD8/16 module provides a 3U high performancedata acquisition subsystem. There are (8) eight or (16)sixteen 100/200 KSPS ADC’s for maximum performance.The Local DSP can be used to simply move data samplesto the CPCI bus or can provide processing functions suchas limit checking, FFT’s, digital filtering, etc. Software canbe downloaded to the DSP via the CPCI interface.Instrumentation amplifiers provide over-voltage protectionand gain on a per channel basis. The CPCI-AD8/16 canalso accept external scan and trigger signals from a frontpanel connector
-
CPCI-AD8 -
ALPHI Technology Corporation
The CPCI-AD8/16 module provides a 3U high performance data acquisition subsystem. There are (8) eight or (16) sixteen 100/200 KSPS ADC’s for maximum performance. The Local DSP can be used to simply move data samples to the CPCI bus or can provide processing functions such as limit checking, FFT’s, digital filtering, etc. Software can be downloaded to the DSP via the CPCI interface.Instrumentation amplifiers provide over-voltage protection and gain on a per channel basis. The CPCI-AD8/16 can also accept external scan and trigger signals from a front panel connector.
-
E9301A -
Keysight Technologies
Measure the average power of all modulation formats Wide dynamic range (-60 dBm to +20 dBm) and frequency range 10 MHz to 6 GHzHigh maximum power specification Low SWR for reducing mismatch uncertainty Calibration factors linearity and temperative compensation data stored in EEPROM Fast measurement speeds (up to 400 readings per second with the Keysight E4416A)Compatible with EPM (new N1913A/ 14A, E4418B/ 19B), EPM-P (E4416A/ 17A) and P-series (N1911A/ 12A) power meters
-
780979-01 -
NI
Non-Enclosed, 500 S/s, ±20 mA, 16-Channel C Series Current Input Module - The sbRIO‑9208 is designed with industrial systems in mind. It includes a high-resolution mode with 50/60 Hz rejection to remove low frequency noise. It has high-channel density to reduce the number of modules needed, which leaves slots open for other measurement types or for reducing the overall per channel cost of the system. The sbRIO‑9208 uses a standard D‑SUB connection for use with cables and connector blocks. Non-enclosed modules are designed for OEM applications.
-
196236-1R5 -
NI
72-Pin, Female Flying Leads to 48-Pin, Male InfiniBand, 100 Ohm, Shielded LVDS Cable - The SHB12X-H3X24 LVDS Cable connects the 12X InfiniBand connector on PXIe-656x LVDS digital instruments or some NI 658x LVDS Adapter Modules for FlexRIO directly to individual header pins. This cable is intended for use with a custom breakout fixture. The flying-lead cable has three signals per grouping for positive, negative, and ground pin connections designed to plug directly into any 0.1 in. header connector. It is a shielded, 100 ohm cable.
-
783284-01 -
NI
±10 V, 1 MS/s, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The NI‑9223 performs differential analog input. This module is well suited for applications such as ballistics, impact, and blast wave testing. The NI‑9223 can sample at the maximum sample rate per channel while the module next to it samples at a much slower rate, which is ideal for mixed-measurement test systems. There are two connector options for the NI‑9223: either four, 2‑position screw terminal connectors or four BNC connectors.
-
781398-01 -
NI
±10 V, 1 MS/s, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The NI‑9223 performs differential analog input. This module is well suited for applications such as ballistics, impact, and blast wave testing. The NI‑9223 can sample at the maximum sample rate per channel while the module next to it samples at a much slower rate, which is ideal for mixed-measurement test systems. There are two connector options for the NI‑9223: either four, 2‑position screw terminal connectors or four BNC connectors.