  • Production Test System

    ETS880 TITAN - Hilevel Technology, Inc.

    *Test rates up to 200MHz (100MHz All Modes) *Clocks up to 400MHz *Two strobes per cycle * High Pin Count: Up to 1,024 logic pins in ONE Chassis *Optionally supports up 4,096 DC pins, or combination of both * Direct Docking precision manipulator *Low Cost *Up to 64Meg test vector depth *Programmable loads and parallel loads *Multiple DC PMU units * Timing On-the-Fly * Mixed Signal Option

  • System of High-Speed Synchronous Registration of Analog, Digital, and Video Signals

    ViTec Co. Ltd

    The system uses a high-performance NI CompactRIO controller to simultaneously register 24 analog signals, receive an accurate digital pulse from GPS and synchronize measurements.The video signal is recorded using a high-speed camera connected to an NI PCIe-1433 frame grabber. The information received from the camera and the recording device is transmitted to a server built on the basis of an industrial computer, which writes data to an external 12-disk RAID array. The stream of recorded data in the system can reach 600 MB per second.

  • Variable Reluctance Absolute Pressure Sensor

    AP10 - Validyne Engineering

    The AP10, Absolute Pressure Sensor, is designed for low and medium pressure measurements, to laboratory accuracy, of corrosive liquids and gases. In typical AC excited bridge circuits, this transducer delivers a full-scale output of 40 mV per volt at 3kHz. The unit operates with carrier systems including the Validyne CD15 sine wave carrier demodulator and CD16 miniature DC input DC output carrier demodulator to produce a high level analog DC output suitable for recording and control.

  • Transformer Rectifier Assemblies

    Carl E. Holmes Company

    Transformer rectifier assemblies are very useful in OEM applications when unregulated DC output is required. Input power can be single-phase or three phases. With single-phase input power, the output ripple is 50%. With three-phase input power, the output ripple is 5%. A 5% output ripple is a clear advantage. Hence, transformer rectifier assemblies with three-phase input power are more popular. Circuit breakers, fuses, voltmeters, and ammeters can be added per customer requirements. The assemblies can be an open frame or inside an indoor enclosure.

  • Automatic Softening Point Tester

    LD-LSPT-A10 - Labodam

    Automatic softening point testerLD-LSPT-A10is a bench top microprocessor controlled analytical unit that determines the softening point of two samples at once. Operated via touch panel it uses ball and ring apparatus for reliable detection. Designed as per Test methods of Bitumen and Bituminous Mixture for Highway Engineering and ASTM D36 Standard test method for Softening of Bitumen (Ring-and-Ball Apparatus) it is ideal for determining the softening points of petroleum asphalts, coal pitch, liquid petroleum asphalt, etc.

  • 8Ch Speaker/Receiver Unit Tester

    BK9012 - BaKo Co., Ltd

    Based on the BK2120A Audio Analyzer, the BK9012 is designed to quickly test microspeakers or receivers 4~8 at a time at a rate that you’ll find hard to keep up with. It tests various frequency characteristics and also rub & buzz so you know the quality of your product is maintained. And of course, you can track the accuracy and stability of your process using the data you’ve saved on about 4 million microspeakers (based on a 6 second total test + load time) per month.

  • Franklin Tester Model

    Model FT2 - Gopal Electronics

    Franklin Tester Model FT-2 is designed as per IS:649 & ASTM:717 Standard to measure insulation resistivity of electrical steel sheet. It requires precision & noise free DC regulated power supply and equally distributed pressure on electrode. Franklin Tester FT-2 regulated power supply provides 0.5000V with 0.1% accuracy over load and no load. Most of national and international standard has specified only 0.5%, means FT-2 is equipped with five time better accuracy than required.

  • Wire Crimp Pull Tester (Motorized)

    WT3-201M - Mark-10 Corp.

    The WT3-201M motorized wire crimp pull tester is designed to measure pull-off forces of up to 200 lbF [1 kN] for wire and tube terminations. The tester conforms to numerous UL, ISO, ASTM, SAE, MIL, and other requirements for destructive testing. Non-destructive testing is also possible, such as pulling to a load or maintaining a load for a specified period of time, as per the requirements of UL 486A/B. Programmable pass/fail limits with red and green indicators and audio alerts help identify non-conforming samples.

  • PXI Relay Driver Module

    NI

    The PXI Relay Driver Module controls up to 64 external relays with up to 50 VDC or 600 mA per channel drive capacity when using an external power supply. Modules can drive small DC motors or other inductive relay coils, and they include overcurrent, overvoltage, and flyback protection to ensure long operation. The PXI Relay Driver Module allows you to build custom switch configurations while using the standard IVIcompliant NISWITCH driver software.

  • Wind Speed Sensor/Anemometer

    ENVIROMUX-WSS - Network Technologies Inc

    Rugged anemometer. 3-cup rotor pressed on a stainless steel shaft. Reed switch and magnet providing one pulse per rotation. Rotor diameter: 5 inches. Speed range: ~ 3 mph to 125+ mph (~5 kph to over 200 kph). Rugged Delrin body with bronze and Rulon bushings. Flat aluminum mounting bracket with 2 holes. esigned to be mounted on top of a pole or bracket. 100 feet of exterior grade wire. Maximum cable length: 1000 ft (305m).

  • P-Series Dual Channel Power Meter

    N1912A - Keysight Technologies

    30 MHz video bandwidth Single shot real time capture at 100 M sample/s per second Key Measurements: - peak, average, peak-to-average ratio, rise time, fall time and pulse width22 Predefined formats: WiMAX, DME, HSDPA, etc. One screen view for pulse measurement analysis: Auto Scale, Auto Gate, Rise/Fall Time, Duty Cycle, etc. Internal Zeroing and Calibration while connecting to the DUT Bench Vue software enabled

  • Tunable Laser Source, High Power And Lowest SSE, Top Line

    N7776C - Keysight Technologies

    The new Keysight N7776C top line tunable laser source is designed to reach best-in-class accuracy in static and swept operation for outstanding test efficiency. Two-way sweeps up to 200 nm/s speed with sub-picometer repeatability and without impacting the specified dynamic accuracy accelerate wavelength-dependent alignment processes and the automated calibration of wavelength-selective devices. Shorter time to testing and faster swept-wavelength tests help reduce test cost per device, improve test margins and lower the cost of ownership.

  • Walking Test System Kit

    PGA-710 - Prostat Corporation

    The PGA-710 Walking Test System is a complete kit designed to perform the walking test per ANSI/ESD STM97.2 and IEC 61340-4-5. The system consist of several devices designed for portability and to perform several different tests which includes measuring the voltage on a person in combination with floor materials and footwear.The kit includes the PGA-710B Data Logger, the PFM-711B Field Meter, CPM-720B Charge Plate Monitor, the PCS-730B Electrostatic Charger, Hand Held Electrode and the Prostat Autoanalysis Software version 2.0.

  • P-Series Single Channel Power Meter

    N1911A - Keysight Technologies

    30 MHz video bandwidth Single shot real time capture at 100 M sample/s per second Key Measurements: - peak, average, peak-to-average ratio, rise time, fall time and pulse width22 Predefined formats: WiMAX, DME, HSDPA, etc. One screen view for pulse measurement analysis: Auto Scale, Auto Gate, Rise/Fall Time, Duty Cycle, etc. Internal Zeroing and Calibration while connecting to the DUT Bench Vue software enabled

  • NI-9208, 500 S/s, ±20 mA, 16-Channel C Series Current Input Module

    785041-01 - NI

    500 S/s, ±20 mA, 16-Channel C Series Current Input Module - The NI‑9208 is designed with industrial systems in mind. It includes a high-resolution mode with 50/60 Hz rejection to remove low frequency noise. It has high-channel density to reduce the number of modules needed, which leaves slots open for other measurement types or for reducing the overall per channel cost of the system. The NI‑9208 uses a standard D‑SUB connection for use with cables and connector blocks.