Showing results: 61 - 75 of 1454 items found.
-
SCOT MXP+ -
Scope T&M Pvt, Ltd.
SCOT MXP+ measures, displays and prints CLOSE, OPEN and CLOSE-OPEN time of 2 Main + 2 PIR contacts per pole, 3 poles simultaneously, ensuring measurement of 6 Main + 6 PIR contacts simultaneously. Ideally suitable for CBs having PIR contacts & multiple breaks per pole
-
Radalert® 100X -
International Medcom
The Radalert® 100X is a general purpose geiger counter that measures alpha, beta, gamma, and X-radiation. Features of the Radalert® 100X, include a three-second update and a Utility Menu that allows you to change the default settings for several operating parameters. Its digital liquid crystal display (LCD) shows the current radiation level in your choice of SI units (microsieverts per hour) from .000 to 1,100 and counts per minute (CPM) from 0 to 350,000 or counts per second (CPS) from 0 to 3,500. For users of conventional units mR/hr (milliroentgens per hour) from .000 to 110 and CPM are optional in the Utility Menu. This instrument also offers an accumulated total and timer function, up to 9,999,000 counts and 40 hours.
-
Elmeasure India Pvt. Ltd
Multiple branches of load can be monitored togetherCan group the device as 3 phase load and single phase loadFaster communication through RS485 port (Modbus protocol)Simultaneous sampling of Volts and AmpsAccuracy Class 1.0 as per IEC 62053-21 & Class 0.5 as per IEC 62053-22 StandardsDisplays more than 25 parameters
-
753 -
Summit
0.2 oz per yr sensitivity Pump Driven Soft Pouch. Capacitance (Max 4mF) Included
-
31-23 -
Testing Machines, Inc.
With this machine, a pliable specimen is placed under a constant tension load. The specimen is then folded to an angle of 135° in either direction, at the rate of 175 double folds per minute until the specimen is severed at the crease. A variable folding rate option allows the operator to vary the folding rate between 20 and 175 double folds per minute.
-
LTX-5515 -
Scitec Instruments Ltd
The LTX-5515 enables the precise conveyance of one analog channel plus four digital channels of information over fibre optic links ranging from metres to more than 10 kilometres. Incoming analogue data is digitised to 12-bit precision at 100 megasamples per second and transmitted over optical fiber at one giga-bit per second.?
-
Desco Industries, Inc.
Analog Compliance Verification Surface Resistance CheckerUse to test worksurfaces, shelving, carts, garments, chairs to ANSI/ESD S20.20 per ESD TR53Automatic Test Range Voltage Selection Per Compliance Verification ESD TR53Starts tests at 10 volts and automatically switches to 100 volts if the measurement is over 105 ohmsPortable Operation with 9 Volt Battery
-
iPQMS-C256 -
Eagle Eye Power Solutions
Around-the-clock UPS protection is achieved through battery monitoring systems that monitor and trend battery health multiple times per day. The iPQMS-C256 is designed for 480V UPS Systems. Ohmic resistance and voltage measurements (per jar) are taken as often as every five minutes. System DC current, DC voltage, and temperature are measured in real-time.
-
Neutronics Manufacturing Co.
Nmc's high voltage test sets are manufactured as per the customers requirement ranging from 5kv-100kv ac or dc.
-
LAP-C(16064) -
Zeroplus Technology Corperation
Bandwidth:75MHzWorking Range: -6V~+6VAccuracy: ±0.1V, Memory:1MbitsDepth(Per Channel):64Kbits (Max 16Mbits for compression)
-
LAP-C(16128) -
Zeroplus Technology Corperation
Bandwidth:75MHzWorking Range: -6V~+6VAccuracy: ±0.1V, Memory:4MbitsDepth(Per Channel):128Kbits (Max 32Mbits for compression)
-
LAP-C(16032) -
Zeroplus Technology Corperation
Bandwidth:75MHzWorking Range: -6V~+6VAccuracy: ±0.1V, Memory:512KbitsDepth(Per Channel):32Kbits (Max 8Mbits for compression)
-
VEGA Grieshaber KG
In flow measurement, the amount of material that flows through a certain pipe cross section per time unit is measured.
-
1OVX606MZ3-1X01R -
ELMA Electronic, Inc.
VPX mesh, 4 lane Fat Pipe, QFP expansion plane, up to 6.25 Gbps per channel
-
UMA, Inc.
The inner scale displays the difference in pressure between the inside and the outside of the cabin in pounds per square inch (PSI).