Filter Results By:

Products

Applications

Manufacturers

Showing results: 7591 - 7605 of 9940 items found.

  • VXT PXI Vector Transceiver, 300/600/1200 MHz Bandwidth

    M9410A - Keysight Technologies

    The Keysight M9410A VXT PXIe vector transceiver integrates a 6 GHz vector signal generator and vector signal analyzer in a 2-slot PXIe module.

  • 1-Channel 3.6 GHz or 2-Channel 1.8 GHz 12-bit A/D with DDC - XMC

    Model 71641 - Pentek, Inc.

    - Ideal radar and software radio interface solution- One-channel mode with 3.6 GHz, 12-bit A/D- Two-channel mode with 1.8 GHz, 12-bit A/Ds- Programmable one- or two- channel DDC (Digital Downconverter- 2 GB of DDR3 SDRAM- Sync bus for multimodule synchronization- PCI Express Gen. 2 interface x8 wide- Optional LVDS connections to the Virtex-6 FPGA for custom I/O- Clock up to four modules with Model 7194 High-Speed Clock Generator - PMC/XMC- Synchronize up to four modules with Model 7192 System Synchronization and Distribution Amplifier - PMC/XMC- Synchronize up to twelve modules with Model 9192 System Synchronization and Distribution Amplifier- 1U Rack-mount

  • PXI Very High Density Versatile 2 Amp Multiplexer

    40-612A-002 - Pickering Interfaces Ltd.

    The 40-612A Very High Density Versatile Multiplexer module features a wide range of software selectable switching configurations. It is especially useful where a number of high density multiplexers are required with the option of easily altering the channel count as a test system evolves. Typical applications include signal routing in ATE and data acquisition systems. The 40-612 module uses high quality electro-mechanical relays, connections are made via a front panel 160 pin DIN41612 connector. The module can be software configured into one of a large number of different multiplexer modes. Relays allow the multiplexer banks to be set in 1 or 2 pole mode and inter-bank switching enables the channel count to be increased up to a maximum of 128

  • RF Amplifier

    SA1022 - Hangzhou Softel Optic Co., Ltd.

    *1000MHz Broadband RF signal amplifier, Line extender, RF amplifier GaAs MMIC used on the forward path, Power-Double module amplify module are used as output stage, Output level is stable and nonlinear index is good, import high index amplify module are used on return path, its distortion is little and SNR is high.*It is more convenient to debug because of plug-in (or adjustable) duplex filters, plug -in fixed (or adjustable) equalizers, plug-in output splitters and scientific and rational on-line detection ports.*The equipment can work steadily outdoor under bad environmental condition because of waterproof aluminum case, high reliability switching power supply and lightning protection system.

  • Isolation Amplifier

    Mornsun Guangzhou Science & Technology

    An isolation amplifier is an amplifier that provides isolation between the input and output of the circuits, including isolation between their associated power supplies. MORNSUN offers different types of analog isolation amplifiers, such as acquisition type signal conditioning modules, output isolation signal conditioning modules, two-wire loop power supply signal conditioning modules and signal isolators, etc. These analog isolation amplifiers feature excellent temperature drift characteristics of less than 50PPM/℃ across the entire operating temperature range of -40 ℃ to +85 ℃ and achieve isolation transmission, signal conversion (programmable for some models), HART communication, signal amplification, port protection and other functions. SIP, DIP, SMD and DIN Rail packages are optional.

  • Analog or Digital Communications Switching Systems with D Type Connectors

    RS Series - Cytec Corp.

    The RS Series computer controlled switching systems are designed to switch multi-wire groups of signal up to 25 wires. These systems are typically used for signals such as parallel TTL, RS232, RS422, WAN or modems, but can also be used for any group of analog or digital signals having a bandpass up to 30 MHz or a data rate up to 20 Mbps. A modular design concept is used that provides configuration flexibility by allowing display modules, different control modules and switch modules to be combined into a single chassis.LED displays and switch point status feedback are available on most systems. Computer control via IEEE488 (GPIB) and RS232 is standard, while TCP/IP Ethernet LAN, USB and manual controls are optionally available.

  • HEV & EV Power Tester

    EVd-40 - NuVant Systems, Inc.

    The EVd-40 Power Tester is a pre- and post-reconditioning tool for quality control of aftermarket HEV & EV battery production. The equipment integrates a “smart” charger (Sorensen XG 1700 or Kepco KLN 1500W) with NuVant Systems high power discharge electronics. The "power test" discharges battery packs at high power (10,000 watts), while tracking module voltages. The software monitors up to 40 module voltages at a time, identifying any weak modules. The "smart" charger performs charging constant current (CC), constant voltage (CV) and complex mixed mode constant current – constant voltage (CCCV) charging protocols at voltages up to 600 V. This enables recharge of any type of rechargeable battery.

  • PXI Very High Density Versatile Multiplexer

    40-612-002 - Pickering Interfaces Ltd.

    The 40-612 Very High Density Versatile Multiplexer module features a wide range of software selectable switching configurations. It is especially useful where a number of high density multiplexers are required with the option of easily altering the channel count as a test system evolves. Typical applications include signal routing in ATE and data acquisition systems. The 40-612 module uses high quality electro-mechanical relays, connections are made via a front panel 160 pin DIN41612 connector. The module can be software configured into one of a large number of different multiplexer modes. Relays allow the multiplexer banks to be set in 1 or 2 pole mode and inter-bank switching enables the channel count to be increased up to a maximum of 128

  • Solar Array Simulator

    LXinstruments GmbH

    Among other things, solar array simulators are required for testing satellite power supplies. An SAS (Solar Array Simulator), consisting of an interconnection of several Solar Array Simulator modules, maps the solar panels and displays the individual strings connected in parallel. Optionally, the individual SAS modules are monitored by a Second Level Protection, so that the test object is not damaged in case of errors with the voltage sources. Additional circuitry is implemented via project-specific test modules. The signal path to the DUT can be separated, e.g. for dynamic current measurements.The Keysight Solar Array Simulators used were specially developed for satellite applications and cover the significantly higher requirements regarding the control speed of MPP tracking compared to terrestrial applications.

  • PXI Dual 12x4 Matrix, 1 Pole Switching

    40-511-021 - Pickering Interfaces Ltd.

    The 40-510 series of matrix modules feature a wide range of selectable switching configurations (12x4,dual 12x4,12x8 and 24x4). Typical applications include signal routing in ATE and data acquisition systems. Available reed relay formats are 1-pole, 2-pole and 1-Pole screened. The screened version is suitable for switching signals up to 50MHz. Larger matrices may be constructed by Daisy Chaining the common signals from multiple PXI modules.

  • PXI 2 Amp Multiplexer, Quad 8-Channel, 1-Pole

    40-635A-108 - Pickering Interfaces Ltd.

    The 40-635A-108 is a quad 8-channel, 1-pole MUX and is part of a range of Multiplexer modules available in 9 standard density and 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC. The module is suitable for signal routing in ATE and data acquisition systems. Connections are made via a front panel 78-way D-type connector.

  • PXI 2 Amp Multiplexer, Single 64-Channel, 1-Pole

    40-635A-001 - Pickering Interfaces Ltd.

    The 40-635A-001 is a single 64-channel, 1-pole MUX and is part of a range of Multiplexer modules available in 9 standard density and 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC. The module is suitable for signal routing in ATE and data acquisition systems. Connections are made via a front panel 78-way D-type connector.

  • PXI 24x4 Matrix, 1 Pole Screened

    40-513-021-S - Pickering Interfaces Ltd.

    The 40-510 series of matrix modules feature a wide range of selectable switching configurations (12x4,dual 12x4,12x8 and 24x4). Typical applications include signal routing in ATE and data acquisition systems. Available reed relay formats are 1-pole, 2-pole and 1-Pole screened. The screened version is suitable for switching signals up to 50MHz. Larger matrices may be constructed by Daisy Chaining the common signals from multiple PXI modules.

  • PXI 2 Amp Multiplexer, Single 16-Channel, 4-Pole

    40-635A-003 - Pickering Interfaces Ltd.

    The 40-635A-003 is a single 16-channel, 4-pole MUX and is part of a range of Multiplexer modules available in 9 standard density and 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC. The module is suitable for signal routing in ATE and data acquisition systems. Connections are made via a front panel 78-way D-type connector.

  • PXI 24x4 Matrix, 1 Pole Switching

    40-513-021 - Pickering Interfaces Ltd.

    The 40-510 series of matrix modules feature a wide range of selectable switching configurations (12x4,dual 12x4,12x8 and 24x4). Typical applications include signal routing in ATE and data acquisition systems. Available reed relay formats are 1-pole, 2-pole and 1-Pole screened. The screened version is suitable for switching signals up to 50MHz. Larger matrices may be constructed by Daisy Chaining the common signals from multiple PXI modules.

Get Help