-
product
PXI/PXIe Microwave Transfer Switch, Dual, 40 GHz, 50 Ω, SMA-2.9, Failsafe
42-782B-542
The 40-782B-542 (PXI) and 42-782B-542 (PXIe) dual failsafe transfer switches are part of our range of PXI microwave switching modules. They have a characteristic impedance of 50 Ω and a maximum operating frequency of 40 GHz. Connections are made via front panel mounted high quality SMA-2.9 coaxial connectors.
-
product
PXI 8-slot BRIC Matrix, 2A, 2-Pole, 399x4, 7 Sub-cards
40-574-107
The 40-574-107 is a 399x4 2-pole matrix and is part of a range of BRIC matrices providing high density configurations capable of switching signals up to 2 A. The modules are available in 2, 4 or 8-slot PXI sizes and are constructed using high quality electro-mechanical relays.
-
product
PXI/PXIe MEMS Optical MUX, Triple 2-Channel, Single-Mode, 9/125 Fiber, LC Connectors
40-855A-432
The 40/42-855A-432 is a PXI/PXIe triple 2-channel multiplexer with LC connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications. They are also available with an optional hardware interlock which, when activated, will return all optical switches to their default unpowered state.
-
product
Isolated D/A Converter 8 Channel, 250kSa/s
OTP2 module no.187
The PXIe‑4322 is a channel-isolated analog output module with built-in signal conditioning. The module provides accurate, simultaneous dynamic voltage and current outputs. By combining signal conditioning and D/A converters in one device, the PXIe‑4322 isolated analog output module offers smaller dimensions and higher measurement performance. In current mode, the module operates in all four quadrants, allowing current to be drawn and sourced. Thanks to isolation and outputs for higher voltages and currents, the module is particularly suitable for applications in the automotive sector.
-
product
PXIe-2738 , 256-Crosspoint, 8x32, 2-Wire PXI Matrix Switch Module
782835-38
256-Crosspoint, 8x32, 2-Wire PXI Matrix Switch Module—The PXIe‑2738 is a high‐density 8x32 PXI matrix switch module designed for routing signals within automated test systems and using electromechanical relays to perform immediate switch operations. It also offers features to monitor the health of deployed systems and plan for predictive maintenance, including onboard relay count tracking, a temperature sensor, and functional and resistive relay self-tests available through the NI Switch Health Center.
-
product
Capacitance Measurement Trainer Module
Unitech Scales And Measurements Pvt. Ltd
Capacitance Trainer comprises of parallel plate/angular capacitor with dielectric medium air as sensor, mounted on the base plate with scale for displacement. Digital indicator is provided to read the change in capacitance in terms of displacement.
-
product
SWB-2812, 16x9, 1 A, Reed Matrix Module for SwitchBlock
781420-12
16x9, 1 A, Reed Matrix Module for SwitchBlock - The SWB‑2812 is a reed relay matrix module for SwitchBlock systems. Designed for high power, it can operate as an individual relay card or expand in a single carrier or single PXI chassis. You can connect any input to any output, individually or in combination. You can use matrix switches to route signals from oscilloscopes, DMMs, arbitrary waveform generators, and power supplies to various test points on a unit under test (UUT). The primary benefit of matrix switches is simplified wiring—the overall test system can easily and dynamically change the internal connection path without any external manual intervention.
-
product
PXI 8-Slot BRIC Matrix, 176x4 1-Pole (4 sub-cards)
40-562B-121-176X4
The 40-562B-121-176X4 is a high density BRIC8 matrix module with a size of 176x4 with 1-pole switching. It is part of a range of BRIC matrices available in 2, 4, 8 or 12-slot formats to suit high performance PXI matrix requirements and is constructed using instrumentation quality reed relays.
-
product
Interface Module
MRS4
The mezzanine provides connection of up to four input and four output interface lines.
-
product
PXI High Density Multiplexer, 1-Bank, 64-Channel, 1-Pole
40-610A-012
The 40-610A-012 is a 1-bank, 64-channel, 1-pole MUX and is part of our range of PXI high density reed-relay based multiplexer modules. The range includes a wide choice of switching configurations which are especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems.
-
product
PXI MUX 8 Banks of 16 Channel 1 Pole
40-610-022-8/16/1
This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer
-
product
NI-9401, 5 V/TTL, 8 Bidirectional Channels, 100 ns C Series Digital Module
779351-01
5 V/TTL, 8 Bidirectional Channels, 100 ns C Series Digital Module - The NI‑9401 is a configurable digital I/O interface for input or output in 4‑bit increments. Therefore, the NI‑9401 can create three configurations: 8 digital inputs, 8 digital outputs, or four digital inputs and four digital outputs. With reconfigurable I/O (RIO) technology (CompactRIO only), you can use the LabVIEW FPGA Module to program the NI‑9401 for implementing custom, high-speed counter/timers; digital communication protocols; pulse generation; and more. Each channel features transient isolation between the I/O channels and the backplane.
-
product
Scales, Modules, Weighing Platforms
The weighing platform is a very precise measuring device for determining weights because of its resolution of 1 g and an accuracy of ± 0.1% of measuring range.
-
product
Modular Breakout System 8-Pin Power D-type Plugin Module for 40-192
95-192-001
The 95-192-001 Plugin Breakout Module is designed to be fitted to a PXI 40-192 Fault Insertion Switch as part of the Pickering MBoS. The Modular Breakout System is designed to Simplify HILS (Hardware In the Loop Simulation) Applications.
-
product
PXI 4 Slot BRIC 120x8 2-Pole (4 sub-cards)
40-561A-022-120X8
This version of our BRIC is part of a range of high-density PXI matrix modules. These modules are available in 2, 4 or 8 slot PXI sizes to suit all high performance matrix requirements and are constructed using instrumentation quality reed relays. With this high level of switching density, these PXI matrix modules allow a complete Functional ATE system to be housed in a single 3U PXI chassis. These BRIC matrix modules allow the use of lower cost 8 or 14-slot PXI chassis.
-
product
PXI/PXIe Microwave Relay, Dual SPDT, 18 GHz, 50 Ω, SMA, Internal Termination, Failsafe, Remote Mount
42-781A-022-E
The 40-781A-022 (PXI) and 42-781A-022 (PXIe) are dual failsafe SPDT 18 GHz microwave relay modules with internal terminations and remotely mounted relays. The 40/42-781A range is available with one or two SPDT switches capable of switching frequencies up to 50 GHz in 50 Ω. They are available with either internal or external terminations and connections are via front panel mounted high quality SMA, SMA 2.9 or SMA 2.4 connectors.
-
product
Motor Termination Units
Since the rise time of IGBTs are in the range of a few tens of nanoseconds (between 50ns-200ns), even short cables between PWM motor drives and motors cause voltage doubling at the motor terminals due to Travelling Wave Phenomenon as in transmission lines. The insulation of motor windings are prone to failure due to high voltage spikes if necessary precautions are not sufficiently taken. RC Type Output Filter Modules reduce these high voltage spikes to protect motors by connecting to stator terminals.
-
product
PXI/PXIe MEMS Optical Switch, Single Insert/Bypass
40-860A-012
The 40/42-860A-012 is a PXI/PXIe single insert/bypass switch with FC/APC connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications. They are also available with an optional hardware interlock which, when activated, will return all optical switches to their default unpowered state.
-
product
REM-11152, 16-Channel (Input), 24 V, 2-, 3-, 4-Wire Digital Module for Remote I/O
784743-01
The REM‑11152 is a digital input module for remote I/O. Remote I/O systems are low-cost, modular systems for simple machine control and measurements. A remote I/O system consists of an EtherCAT bus coupler and individual modules mounted on a DIN rail. You control the REM‑11152 from a real-time controller, such as a CompactRIO Controller or an Industrial Controller. You can use remote I/O hardware to add low-cost I/O for simple tasks while your controller handles advanced tasks such as image proc...show more -
product
PXI-4461, 204.8 kS/s, 2-Input/2-Output PXI Sound and Vibration Module
779687-01
204.8 kS/s, 2-Input/2-Output PXI Sound and Vibration Module—The PXI‑4461 is designed for sound and vibration applications. It provides two-channel dynamic signal generation and two-channel acquisition, and you can use one of six gain settings to configure your input range. The PXI‑4461 also includes software-configurable AC/DC coupling and IEPE conditioning. The PXI‑4461 includes the hardware and software needed to make precision measurements with microphones, accelerometers, and other transducers that have very large dynamic ranges. Common applications include audio test; automotive noise, vibration, and harshness (NVH); and machine condition monitoring.
-
product
PXI 5A Mux 8-Bank 5-Ch Isolated COM
40-651-014
This range of high density power multiplexer modules is suitable for switching inductive/capacitive loads up to 5A at 250VAC. It is available in the following 1-pole multiplexer formats: 1-bank 48-channel. 2-bank 24-channel. 4-bank 11-channel. 8-bank 5-channel.Connections are made via a front panel 50-way male D-type connector. Power multiplexer modules are intended for switching heavy AC or DC loads or for slaving up to large external relays, contactors and solenoids.
-
product
NI-9262, 1 MS/s/ch Simultaneous, ±10 V, 6-Channel C Series Voltage Output Module
785503-01
1 MS/s/ch Simultaneous, ±10 V, 6-Channel C Series Voltage Output Module - The NI-9262 is a simultaneously updating analog output module. It features overvoltage protection, short-circuit protection, low crosstalk, fast slew rate, high relative accuracy, and NIST-traceable calibration. The NI-9262 module includes a channel-to-earth ground isolation barrier for safety and noise immunity.
-
product
POWER INTERFACE BOX
The POWER Box is in charge to provide power supply lines towards the UUT simulating the power distribution unit. The box has been designed to host, in any mixed configuration, two kind of plug in modules:
-
product
Programming Module
PM Series
*Small, simple to use module for programming EM Research synthesizers *Programmed frequency easily read on large LED display *No programming experience needed to operate, clear instructions included *Integrates with EM Research products to get your system up and running as quick as possible
-
product
PXI 5A Power Multiplexer, 8-Bank, 5-Channel, Isolated Common
40-651A-014
The 40-651A-014 is part of our range of high density power multiplexer modules is suitable for switching inductive/capacitive loads up to 5A at 250VAC. It is available in the following 1-pole multiplexer formats.
-
product
RF Amplifier
SA1001H
Hangzhou Softel Optic Co., Ltd.
*SA1001H Indoor Bi-directional Amplifier are special amplifiers designed for the last”1km” of the bi-directional transmission network.. Special CATV RF modules packaged in SOT-115 are used as forward channel; Microwave tube push-pull circuit with low noise are used as backward channel ;It has the characteristics of low power consumption,high reliability and excellent cost performance. And it is suitable for small and medium sized CATV bi-directional transmission network*It is more convenie...show more -
product
VME Analog Output Module
DP-VME-2115
DP-VME-2115 is an industrial standard 24 channel D/A (Digital to Analog) board. It incorporates most of the features which are demanded in industrial applications. Each Digital to Analog Converter (DAC) is provided with a separate reference voltage selection either from internally generated reference or from the external input. This external input reference signal is passed into the protection circuits before it is fed to any active components. The input protection circuit is designed for ± 25Vp-p input ranges. The DAC output may be unipolar or bipolar and the output is jumper selectable, which is routed to the VME P2 connector, with short circuit protection of upto 30mA.
-
product
Data Acquisition Modules
Omega offers a high performance Data Acquisition products. Omega carries the right product for the input/output requirements of your application.
-
product
PXI 75 x Normally Closed Relay 1A 60W
40-145-101-NC
The 40-145/46/48 range of high density switching modules are available in Normally Open (SPST & DPST) and changeover (SPDT) configurations. Connections are made via a front panel 200 pin female connector.
-
product
Plug and Play Potentiometer Input Module
DSCUSB-PT
The DSCUSB-PT is a compact, high-precision potentiometer input module; converting a resistance based input (potentiometer) to a digital output. Can be used with resistance based sensors to indicate position, rotation and angle. Aimed at applications which require high accuracy. Simply by plugging the device into a PC, data can be extracted from the potentiometer input to the DSCUSB-PT for a wide range of applications. This is achieved using the DSCUSB Toolkit software, which is a simple configuration tool designed specifically for configuring DSCUSB modules. It allows configuration, calibration, logging and parameter management of the modules.