Filter Results By:

Products

Applications

Manufacturers

DC

Direct Current

See Also: Direct Current


Showing results: 3346 - 3360 of 3691 items found.

  • Magneto-Electric Rotation Detector

    MP-981/AP-981 - Ono Sokki

    The MP-981 is a magneto-type detector using a hall element which is suitable for revolution (r/min) measurement from low speed to high speed.Magneto-type detectors use an internal hall element, a permanent magnet, DC amplifier, and voltage regulator and respond to flux, so that a rectangular wave form is derivable from much lower speed all the way though high speed.In addition, a signal indicator is provided in spite of the detector's compact design, making verification of operation and mounting position possible.Meanwhile, the AP-981 is the water and acid proof type, which conforms to Class ' of JIS C0920.

  • Single 8x2 1-Pole 16 Amp PXI Power Matrix

    40-552-002 - Pickering Interfaces Ltd.

    The 40-552 range of 16 Amp PXI power matrix modules is available in four configurations with matrix sizes of 8x2 and 4x4 and the ability to expand the matrix size with the Y-Axis loop-thru connections: e.g. 8x4, 12x4, 16x4, etc. (with 4x4 matrices) or 16x2, 24x2, 32x2, etc. (with 8x2 matrices). This range is capable of switching up to 16 Amps and up to 300VDC/250VAC hot switching and 400VDC/250VAC cold switching. These PXI power matrix modules are intended for switching heavy AC or DC loads or for the slave switching of large external relays, contactors, and solenoids.

  • Single 4x4 1-Pole 16 Amp PXI Power Matrix With Loop-Thru

    40-552-011 - Pickering Interfaces Ltd.

    The 40-552 range of 16 Amp PXI power matrix modules is available in four configurations with matrix sizes of 8x2 and 4x4 and the ability to expand the matrix size with the Y-Axis loop-thru connections: e.g. 8x4, 12x4, 16x4, etc. (with 4x4 matrices) or 16x2, 24x2, 32x2, etc. (with 8x2 matrices). This range is capable of switching up to 16 Amps and up to 300VDC/250VAC hot switching and 400VDC/250VAC cold switching. These PXI power matrix modules are intended for switching heavy AC or DC loads or for the slave switching of large external relays, contactors, and solenoids.

  • Single 8x2 1-Pole 16 Amp PXI Power Matrix With Loop-Thru

    40-552-012 - Pickering Interfaces Ltd.

    The 40-552 range of 16 Amp PXI power matrix modules is available in four configurations with matrix sizes of 8x2 and 4x4 and the ability to expand the matrix size with the Y-Axis loop-thru connections: e.g. 8x4, 12x4, 16x4, etc. (with 4x4 matrices) or 16x2, 24x2, 32x2, etc. (with 8x2 matrices). This range is capable of switching up to 16 Amps and up to 300VDC/250VAC hot switching and 400VDC/250VAC cold switching. These PXI power matrix modules are intended for switching heavy AC or DC loads or for the slave switching of large external relays, contactors, and solenoids.

  • PXI 8x4 1-Pole 10A Matrix With Loop-Thru

    40-551-101 - Pickering Interfaces Ltd.

    Used for switching inductive/capacitive loads up to 10A with 125VDC/250VAC hot switching and 400VDC/250VAC cold switching. X and Y connections are made via a 20-way GMCT plug, this module with loop-thru has an additional 20-way GMCT plug for module-to-module connection. This version of the 40-551 may be expanded to larger matrix sizes using cabling to daisy-chain the X and Y signals Power Matrix Modules are intended for switching heavy AC or DC loads or for slaving large external relays, contactors and solenoids. Suitable for applications requiring switching of either mains voltage or direct current.

  • Digital Protective Relay Test Set

    K1066+ - KINGSINE Electric Automation Co., Ltd.

    1. Adopts 6.4 large LCD screen, and provided with VGA video interface, making it available to connect to projector for training;2. With alarm function of housing grounding testing and external voltage input, to guaranty personal security;3. Offer independent Aux. DC to tested devices, 0 ~ 300V/0.6A(Poleless and adjustable);4. Two in one of meter and source, with function of both internal and external testing, self-calibration, oscillograph, and the duration of each oscillograph reaches 50S (optional function);5. Function of transducer and energy meter testing (optional function);

  • Solar Pump Inverter

    750w-18kw - Shenzhen Setec Power Co., Ltd.

    1. Solar pumping system is composed of a solar array,a pump and a solar pumping inverter. Based on the design philosophy that it is better to store water than electricity , there is no energy storing device such as storebattery in the system. The solar array,an aggregation of many solar modules connected in series and parallel , absorbs sunlight radiation and converts it into electrical energy , providing dynamical water for the whole system. The pumping inverter controls and adjusts the system operation and converts the DC produced by solar array into AC to drive the pump , and adjust the output frequency intensity to realize the maximumpower point tracking (MPPT) .

  • Clamp Meters

    Fieldpiece Instruments, Inc

    The Compact Clamp Meter, incorporates a lot of big meter functions into a compact, easy to use design. While it’s not exactly an all-in-one multimeter, this auto ranging digital multimeter is an affordable meter for the HVACR electrical testing HVACR professionals use everyday. Along with standard multimeter ranges, we designed the SC220 to include microamps DC for flame rectification. Add to that, we designed it with built-in non-contact voltage and a continuity beeper to give you a powerful HVACR meter that’s under 8-inches tall. Makes a great backup or a solid performer for everyday testing.

  • PXI Single 6-Channel 30A Solid State MUX

    40-667-012 - Pickering Interfaces Ltd.

    The 40-667 is a high current multiplexer available in dual 3-channel or single 6-channel configurations occupying two slots of PXI chassis. Each multiplexer switch uses a fully isolated solid state relay which has been designed to offer fast operation under hot switching conditions and high inrush current with no operational life degradation. Each multiplexer channel can support 30A of continuous current and switch up to 40V signals. The switches can sustain inrush currents in excess of 120A. AC or DC signals can be switched since the switch is polarity insensitive.

  • PXI 8x4 Power Matrix, 2 Pole

    40-550-002 - Pickering Interfaces Ltd.

    Connections are made via a front panel 37-way D-Type male connector or two 20-way GMCT male connectors. Used for switching inductive/capacitive loads up to 5A at 250VAC. Power matrix modules are intended for switching heavy AC or DC loads or for slaving up to large external relays, contactors and solenoids. Used for applications requiring switching of either mains voltage or direct current. These modules are fitted with electro-mechanical power relays, gold-flash over silver alloy. A spare relay is built onto the circuit board to facilitate easy maintenance with minimum downtime.

  • Single 4x4 1-Pole 16 Amp PXI Power Matrix

    40-552-001 - Pickering Interfaces Ltd.

    The 40-552 range of 16 Amp PXI power matrix modules is available in four configurations with matrix sizes of 8x2 and 4x4 and the ability to expand the matrix size with the Y-Axis loop-thru connections: e.g. 8x4, 12x4, 16x4, etc. (with 4x4 matrices) or 16x2, 24x2, 32x2, etc. (with 8x2 matrices). This range is capable of switching up to 16 Amps and up to 300VDC/250VAC hot switching and 400VDC/250VAC cold switching. These PXI power matrix modules are intended for switching heavy AC or DC loads or for the slave switching of large external relays, contactors, and solenoids.

  • LED Driver Online Tester

    LEDLS-60/LEDLS-12 - Lisun Electronics Inc.

    • The tester includes A Group Measuring Module and B Group Measuring Module. The A Group measuring module can test 6pcs LED Driver AC Parameters. The B Group measuring module can test 6pcs LED Driver AC, DC and AC/DC Parameters. • There are 12 windows to display the input and output parameters, it is good for comparing and analyses. • Quick test for all of the parameters in 0.1 seconds. • It can set up the testing parameters PASS/FAIL range, it will have Noise/Light warning if it is Fail. We also supply handle port (Extra cost) • Software communicate with PC (Extra cost)

  • High Voltage EMC Surge Generator

    TM510 - T&M Tools Limited Co

    TM510 Surge Generator is mainly used for testing power cable high-resistance and arc-over fault whose grade range is 0-10kV, co-operating with cable fault tester and locating devices to test and locate faults. If the user choose the professional digital milli-ampere-meter, as for cable with grade range about 0- 6kV, the instrument can also be used to do DC&voltage resistance test and current leakage test after the fault is repaired. The instrument is internally equipped with voltage-rise rectifying and discharging device, has complete functions, and is also convenient and safe to be wired and operated.

  • Hipot & Electrical Safety Testers

    Xitron Technologies Inc.

    Vitrek hipot testers serve a range of different industries and are designed by experts who have made the company a global leader for supporting electrical safety tests. Each series of hipot testers is designed to handle AC and DC hipot, and select models can also measure IR insulation resistance. Vitrek manufactures two different series of hipot and electrical safety testers. These hipot testers have been designed to fit your testing application. Each series offers 6 different models with a wide variety of electrical safety test functions and capabilities.

  • Power Cable Fault Locator

    TM500  - T&M Tools Limited Co

    TM500 Power Cable Fault Locator adopts international advanced electronic testing technologies and SCM technology, and combines low-voltage pulse reflection and pulse current testing methods, is suitable for the precise range finding of power cable high resistance, flashover, disconnection, and low resistance. Low-voltage pulse reflection method applies to test the range of the low resistance and broken line, and the length and wave velocity of various cables. Pulse current testing method can be divided into breakthrough high-voltage flashover and DC high-voltage flashover for the high resistance and flashover cable fault finding.

Get Help