Showing results: 1141 - 1155 of 3691 items found.
-
84904K -
Keysight Technologies
The Keysight 84904K programmable step attenuator offers coaxial measurements to 26.5 GHz in a compact, rugged design. It offers repeatability of better than 0.03 dB, excellent life (greater than 5 million switching cycles per section) and attenuator range of 0 to 11 dB in 1-dB steps. This latest design evolution sets new standards for size and performance. High attenuation accuracy and low SWR are achieved through the use of miniature thin-film attenuation cards composed of high-stability tantalum nitride film of saphire substrate. Insertion loss is outstanding, with less than 2 dB of loss at 26.5 GHz. The compact size of the unit, 35% smaller than the Keysight 8495/7 (26.5 GHz) family, allows for easy integration into instruments and ATE systems.
-
84907L -
Keysight Technologies
The Keysight 84907L programmable step attenuator offers coaxial measurements to 40 GHz in a compact, rugged design. It offers repeatability of better than 0.03 dB, excellent life greater than 5 million switching cycles per section) and an attenuation range of 0 to 70 dB in 10-dB steps. This latest design evolution sets new standards for size and performance. High attenuation accuracy and low SWR are achieved through the use of miniature thin-film attenuation cards composed of high-stability tantalum nitride film of saphire substrate. Insertion loss is outstanding, with with only 2,4 dB of loss at 40 GHz. The compact size of the unit, 35% smaller than the Keysight 8495/7 (26.5 GHz) family, allows for easy integration into instruments and ATE systems.
-
N7954A -
Keysight Technologies
The N7954A is designed for automated test equipment (ATE) applications where high-speed dynamic sourcing and measurement is needed.
-
N7973A -
Keysight Technologies
The N7973A is designed for automated test equipment (ATE) applications where high-speed dynamic sourcing and measurement is needed.
-
PE8203 -
Pasternack Enterprises, Inc.
Pasternack adjustable phase trimmer PE8203 is part of our large selection of in-stock RF, microwave and millimeter wave components available for purchase. This adjustable phase trimmer is manufactured with SMA connectors and has a phase adjustment of 10 degrees. Our SMA adjustable phase trimmer has a minimum frequency of DC and a maximum frequency of 18 GHz.
-
72-3100 -
Tenma
600A 750V True RMS Clamp Meter with OLED Display.
-
CK521A -
Spanawave Corporation
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
CK520A -
Spanawave Corporation
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
85514A -
Keysight Technologies
Easily calibrate non-insertable devices with a type-N (m) 50 Ω open, short, load, and through in a compact unit
-
85519A -
Keysight Technologies
Easily calibrate non-insertable devices with this module combining an open, short, load, and through in a compact unit
-
85518A -
Keysight Technologies
Easily calibrate non-insertable devices with this module combining an open, short, load, and through in a compact unit
-
Extech 382275 -
Extech Instruments Corporation
The Extech 382275 power supply is an easy-to-configure, highly stable, lab grade DC power supply with maximum output power of 600 Watts. The new DC power supply offers two degrees of control over both current and voltage outputs (course and fine). Output is adjustable from 0 to 30 Volts DC and 0 to 20 Amps with (0.1 Volts/Amps resolution). Dual green LED displays offer easy-to-read, high contrast readouts of voltage and current values. The 382275 offers four operating modes: normal mode, with values controlled by front-panel knobs; preset mode, which offers three popular voltage presets at 20 Amps: 5.0 Volts, 13.8 Volts, and 25 Volts; set mode, with three user-customizable presets; and remote control mode, where the user can remotely adjust output power on/off, voltage and current. Other features include automatic constant current and voltage, high RFI immunity, excellent EMI, a thermostat-controlled variable speed fan, as well as over-voltage, over-temperature, and short circuit protection. The 382275 offers a compact, low profile design and small footprint without compromising output noise and transient response factors. Complete with power cord.
-
Extech 382276 -
Extech Instruments Corporation
382276 is a Switching Mode DC Power Supply has an adjustable output of 0 to 30V/ 20A with two user-defined presets and one 13.8V/20A factory preset. Power supply features dual LED displays, high RFI immunity, excellent EMI, and a Thermostatic Control Fan. Additional features include over-voltage, over-temperature, and short circuit protection. Operates at 220V, 50/60Hz and comes complete with AC power cord.
-
J7204B -
Keysight Technologies
The J7204B is a multi-channel (4-channels) attenuation solution for signal attenuation and conditioning of up to 4 devices under test (DUT). Operating frequency from DC to 18 GHz, with 121 dB, 1 dB steps. Exceptional 0.03 dB insertion loss repeatability per section for the entire 5 million cycles and excellent attenuation accuracy and flatness, the J7204B reduces cost of ownership and provide the best measurement accuracy.
-
J7205B -
Keysight Technologies
The J7205B is a multi-channel (5-channels) attenuation solution for signal attenuation and conditioning of up to 5 devices under test (DUT). Operating frequency from DC to 18 GHz, with 121 dB, 1 dB steps. Exceptional 0.03 dB insertion loss repeatability per section for the entire 5 million cycles and excellent attenuation accuracy and flatness, the J7205B reduces cost of ownership and provide the best measurement accuracy.