Filter Results By:

Products

Applications

Manufacturers

DC

Direct Current

See Also: Direct Current


Showing results: 3166 - 3180 of 3660 items found.

  • HandyScope HS6-DIFF With SafeGround: 200 MS/s, 250MHz BW, 4 Channel (256MS/ch), USB Differential Digital Storage Oscilloscope, Spectrum Analyzer, Voltmeter, Transient Recorder

    HS6-DIFF-200XMG-W5 - TEAM SOLUTIONS, INC.

    - 1GS/s sampling and flexible resolution of 8-16 bit.- Four input channels up to 250 MHz analog bandwidth- Highly accurate 1 ppm time base- DC Accuracy of 0.25 % and 0.1 % typical- Very fast 200 MSamples per second USB streaming Data logger- Spectrum analyzer with 32 million bins- Optional SureConnect connection test on all channels- Up to 256 MSamples memory per channel

  • HandyScope HS6-DIFF With SafeGround With SafeGround & SureConnect

    HS6-DIFF-100XMSG-W5 - TEAM SOLUTIONS, INC.

    - 1GS/s sampling and flexible resolution of 8-16 bit.- Four input channels up to 250 MHz analog bandwidth- Highly accurate 1 ppm time base- DC Accuracy of 0.25 % and 0.1 % typical- Very fast 200 MSamples per second USB streaming Data logger- Spectrum analyzer with 32 million bins- Optional SureConnect connection test on all channels- Up to 256 MSamples memory per channel

  • Relay Test Set

    RNT-5A - Neutronics Manufacturing Co.

    This is a portable testing kit in one unit, suitable for testing protective relay, over current relay, earth fault relay, protective device, circuit breaker, tripping coils etc.The set is designed for both laboratory and field use. TECHNICAL FEATURES: INPUT : 230 Volts, single phase, 50Hz. AC. OUTPUTS : : 1) Current Output: a) 0- 1Amp. At 6/60Volts. (Continuous duty). b) 0- 5 Amps. At 6/60 Volts. (Continuous duty). c) 0- 10 Amps. At 6/60 Volts. (Continuous duty). d) 0- 20 Amps. At 6 Volts. (for30 min. duty). e) 0- 50 Amps. At 6Volts. (For 10 min. duty). f) 0-100 Amps. At 6 volts. (For10 min. duty). g) 0-200 Amps at 6Volts. (For 30 sec. duty). Current output is continuously variable and the output is taken out through a multi range C.T. The secondary is connected to an ammeter scaled in 0 to 100%. Output current range 1Amp. To 20Amps. Are selected by current range selector switch with common output terminals and for other three ranges three brass terminals are provided of proper ratting. 2) AC Voltage Output: Continuously variable 0 -230V AC. Capacity- 240VA (Max). OR DC Voltage Output: Continuously Variable 0-240V DC. Capacity-240VA.(max). One change over switch should be provided for selection of Volt. Meter for AC or DC voltage output & either AC or Dc voltage should be available at a time. 3) Time Measurement: 0-9.999Secs. & 0-99.99Secs. in two ranges. Accuracy: 1% CURRENT CIRCUIT: Loading transformer: Double winding loading transformer of suitable burden to provided corresponding current output specified before. One change over switch in current ckt. To be provided for voltage selection i.e. selection of 10volt. Or 50volt. Measuring CT: Multi ratio wound primary current transformer Ratio : 1-5-10-20-50-100-200A/5A. Variable auto transformer: For smooth variation of current output at various ranges selected. Tripping circuit: The current output will be cutoff incase of any overload for the range 200A or even if the relay under test actuated.

  • Three-Phase Transformer Demagnetizer

    DEM60C - IBEKO Power AB

    After a DC current test, such as winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remnant magnetism). It can cause various problems such as wrong diagnostics, inaccurate measurements on a transformer, inrush current at the start-up of a power transformer, or incorrect operation of protective relays due to magnetized CT cores. The best way to eliminate this source of potential problems is to use demagnetizer on the power or instrument transformer.The DEM60C is a fully automatic test instrument which performs three-phase transformer demagnetization. Transformer magnetic core demagnetization requires the application of AC current with magnitude decreasing to zero. DEM60C provides this AC current by internally changing the polarity of a controlled DC current. During the demagnetization process, the instrument supplies the current at decreasing magnitude for each step, following a proprietary algorithm. It can demagnetize single-phase and three-phase power transformers.The instrument can be connected to all three phases of a power transformer to be demagnetized, on either the primary or the secondary side. If a user selects specific vector diagrams for different types of transformers, DEM60C will run a specific demagnetization procedure for each transformer type (i.e., single phase, delta, wye/star, zig-zag.) without switching the test leads.DEM60C enables safe and efficient power transformer demagnetization. The instrument automatically regulates the injection of current and discharging energy from the inductance. During and after the operation, an intrinsically safe discharge circuit with an indicator rapidly dissipates the stored magnetic energy. The discharging circuit is independent of the power supply, which improves its reliability in case of loss of power.Test currents of up to 60 A DC enable efficient demagnetization of even the largest power transformers. Using a DV Win software, it is possible to control DEM60C externally.

  • Gauss Meters

    PCE Instruments

    A gauss meter displays electromagnetic wave measurements in Gauss (G), milliGauss (mG), milliTesla (mT) or microTesla (µT) units. A gauss meter can detect either static (DC) permanent (rare-earth) magnetic or dynamic (AC) electromagnetic fields (EMFs), or both. Thus, it is important to review the specifications of a gauss meter prior to purchase to ensure suitability for the intended application.Neodymium (NdFeB) permanent magnets are among the world's strongest and most widely used magnets. When testing magnets made of neodymium or other rare-earth elements, a gaussmeter or magnetometer capable of measuring DC magnetic fields is required. However, most electromagnetic fields encountered are generated by AC currents. Examples include electrical power lines, transformers and wiring for overhead lighting, solar panels and other electrical devices and equipment. Electromagnetic fields from electrical installations are believed to cause feelings of nervousness, anxiety and paranoia in EMF-sensitive human beings.Most gaussmeters offered by PCE Instruments can be calibrated and certified according to DIN ISO 9000 standards for an additional fee. Replacement gaussmeter probes and optional accessories are available for most gaussmeter models.

  • ±6 kV ANSI/ESDA/JEDEC 2-Pin HBM Tester

    HBM-S1-B - High Power Pulse Instruments GmbH

    *±6 kV Human-Body-Model (HBM) 2-pin tester according ANSI/ESDA/JEDEC JS-001 standard with C = 100 pF, R = 1.5 kΩ discharge network*True HBM: the classical discharge network of the HBM-S1-A according the standard ensures compliant waveforms for all load conditions*Optionally available upgrade for all HPPI TLP-3010C, 4010C, 8010A, and 8010C hardware systems and software (upgrade on request)*Suppression of trailing pulses*Integrated 10 kΩ charge removal resistor*Integrated DUT voltage and DUT current sensor for real time voltage and current monitoring*Integrated DC test DUT switchIntegrated hardware 50 Ω trigger output for high speed digital oscilloscopesIntegrated overvoltage protection of voltage sense and DC test interfaces for oscilloscope and SMU protection during high voltage HBM testing*Fast and efficient HBM measurements including transient waveform data management using the HPPI TLP software*Compact size 145 mm x 82.5 mm x 44 mm

  • High Voltage Isolator for Logic Analyzers

    LX-08 - Link Instruments

    The LX-08 series of high voltage logic analyzer adapters provides a safe isolated method of measuring high voltage control signals with a low voltage logic analyzer. All inbound signals are optically isolated and attenuated to a safe level for the delicate inputs typically found on logic analyzers. The inputs on the LX-08 are capable of withstanding voltages up to +/- 300V AC/DC, higher voltage configurations are available upon request. Rather than probing with multiple neon screwdrivers, the LX-08 can provide simultaneous viewing of up to 8 circuits in the STANDALONE mode via the indicator array. Need to catch a transient event or map out a timing sequence? Just add a logic analyzer to the outputs of the LX-08 and turn it into a high voltage logic analyzer. High voltage signals that were hazardous for a logic analyzer can now be measured safely. Typical outputs of a high speed PLC sequencer can be precisely timed and measured from both sides of the control relay. With the built in user selectable AC filter circuit, an AC signal can be measured as DC events or AC cycles.

  • 3.5" Embedded SBC With Intel® Pentium® Processor N4200 & Celeron® Processor N3350, VGA/LVDS, Dual LANs And Audio

    CAPA318 - Axiomtek Co., Ltd.

    The CAPA318 features the Intel® Pentium® processor N4200 or Celeron® processor N3350 (codename: Apollo Lake) with low power consumption. The integrated 3.5-inch embedded board is highly expandable and customizable. It comes with RS-232 ports, USB 3.0 ports, USB 2.0 ports, IN/OUT digital I/O ports, VGA port, LVDS port, and Gigabit Ethernet ports with Intel® i211AT Ethernet controller. For storage needs, the CAPA318 provides one SATA-600 socket and one mSATA interface. Additionally, Its compact and fanless design makes it perfect for use in space constricting environments. Additionally, the 3.5” single board computer can handle a wide operating temperature range from -20°C to +70°C (-4°F to +158°F) and requires +12V DC power input to ensure operational stability in a variety of harsh environments. This cost-effective 3.5” embedded motherboard is suitable for IoT/M2M related applications, industrial control, self-service terminals, digital signage, POS/kiosk displays, just name a few.

  • 800MM 31.5In Digital Level Bevel Gauge w/ LCD Backlight Screen, Level Bubbles IP54 Standards

    DL411 - Advance Plus Trading Co., Ltd.

    Model Number: DL411 Key Specifications/Special Features: 800MM 31.5INCH Digital Level with level bubbles, 2 hand shanks, LCD bright backlight display, IP54 standards 1. 800mm 31.5inch level with 2 bubbles, 800*28*64mm(L*W*H), net weight: 700g;2. Resolution: 0.05°;3. Horizontal level measuring range: 0 to 360°;4. Accuracy: ±0.3°;5. Measures angle in degrees, IN/FT, mm/m, % slope or pitch;6. Audible tone at level, plump and setting angle;7. Automatic shut-off after 3 minutes;8. Backlight LCD;9. Self checking accuracy;10. Self calibration;11. Hold-function to freeze the measurement;12. Memory recall (9 measurements);13. 2pcs Handshanks design, easy to take and use;14. 2pcs high accuracy horizontal & vertical bubbles, clearly to check;15. Operated by DC 3V (2*LR03 AAA 1.5V batteries, not included); 16. IP54 waterproof & dusyproof industrial standard.

  • Non-Contact Type Magneto-Electric Rotation Detector

    MP-9820 - Ono Sokki

    MP-9820 is a magneto-electric-rotation detector using an internal hall element, a permanent magnet, DC amplifier, and voltage regulator in its compact body. Using MP-9820 in combination with detection gear enables deriving stable rectangular waveform from ultra low speed all the way through high speed. (1 Hz to 100 kHz)MP-9820 finds wide range of applications and rotational measurement objects by using with TM-3100 series tachometer and FV-1500 FV converter.

  • Digital Earth Resistance Tester

    ERT-1501 - Neutronics Manufacturing Co.

    Electronic Digital Earth Resistance Tester is direct replacement of the conventional hand generator type tester. It is designed for measurement of the resistance of earthing used in the electrical equipment as well as for measurement of ground resistivity. It can be used for measurements of the other low regular and liquid resistances. It can also be used for measurement of voltage AC, voltage DC and resistance. This instrument finds wide application for testing earthing installation in power based industries, telecommunication networks and electrical traction systems etc.

  • Signal Analyzer

    Anritsu Corporation

    Choose from an extensive selection of signal analyzer products from DC to 44.5 GHz and extendable to 325 GHz.With excellent total level accuracy, dynamic range and performance, Anritsu spectrum/signal analyzers not only can capture wideband signals but FFT technology supports multifunction signal analyses in both the time and frequency domains. Moreover, the built-in signal generators on some models outputs both continuous wave (CW) and modulated signals for use as a reference signal source.

  • PXI Single 8x2 1-Pole 10A Power Matrix

    40-551-002 - Pickering Interfaces Ltd.

    Used for switching inductive/capacitive loads up to 10A with 125VDC/250VAC hot switching and 400VDC/250VAC cold switching. X and Y connections are made via a 20-way GMCT plug, the 8x4 module with loop-thru has an additional 20-way GMCT plug for module-to-module connection. Power Matrix Modules are intended for switching heavy AC or DC loads or for slaving large external relays, contactors and solenoids. Suitable for applications requiring switching of either mains voltage or direct current.

  • Automated Connector Tester

    Get Control, Inc.

    GCI's Automated Connector Tester is a self-contained test bench providing reliable testing of filtered and non-filtered electrical connectors. The ACT automates the tedious process of testing each pin against all others and shell for DC and AC leakage. For filter connectors, the ACT accurately measures pin-to-shell capacitance. For pins protected by diodes, the ACT provides leakage and breakdown measurements. The ACT also verifies pins which are intentionally shorted to each other or to the shell.

  • Low Noise Amplifier

    ERAVANT

    Low noise amplifiers, or LNAs, are designed and manufactured by utilizing the most advanced PHEMT or MMIC devices, thin film technologies, and an improved DC power supply to deliver a low noise performance with broad operating bandwidths and good gain flatness. While standard models focus on general purpose applications, additional models with differing frequency ranges, gains and noise figures are listed on the website. Custom designs are also offered to meet any user’s specific needs.

Get Help