  • CombiVolt™ 1 Voltage/Continuity Tester

    DL6780 - Di-Log

    Testing of AC/ DC voltages from 12 to 690 V AC/DC Continuity testing with optical and acoustic indication Automatic switching between voltage and continuity Phase rotation test system Single pole phase indication Fully compliant with GS38 Fully operational voltage indication even when batteries are discharged Will not trip any RCD when testing across Live and Earth Single pole detection when L2 probe connected above 100V

  • Frequency Converter

    Georator Corporation

    A frequency converter, also known as a frequency changer, is a device that takes incoming power, normally 50 or 60 Hz and converts it to 400 Hz output power. Different types of power frequency converters exist, specifically, there are both rotary frequency converters and solid state frequency converters. Rotary frequency converters use electrical energy to drive a motor. Solid state frequency converters take incoming alternating current (AC) and converts it to direct current (DC).

  • Switch Mainframe

    SW1002 - HIOKI E.E. Corp

    Switch between voltmeter and battery tester while testing. 264 channels max. (2-wire) to 72 channels max. (4-terminal pair). Circuit design friendly for impedance measurements that minimize errors between channels (Effect: 0.01% f.s.*). For BT4560 100 mΩ range, R measurements, and a measurement frequency of 1 kHz. For OCV measurement, internal resistance measurement, and external potential measurement of battery cells. Measure battery modules up to 60 V DC.

  • HV Test System up to 20000 Volt

    LXinstruments GmbH

    Insulated test booth with large space for test items. 2 banana sockets for AC connection and 4 banana sockets for the DC connection of the DUTs. IC’s are tested in a long-term test. These are checked in an oil bath so that there are no air gaps to reduce the insulation. Maximum voltage 20 kV. Therefore, insulation tests must be carried out. Ensuring the standard-compliant test. For the safety of the operating personnel, the test cell is electrically locked while the high voltage measurement is active.

  • Connector Test

    Applied Relay Testing Ltd.

    A connector test system which provides expansion of up to 160 Kelvin pair connections. The system incorporates high voltage AC and DC power supplies with a maximum output of +/- 2100 Volts peak for Hi Pot, Insulation resistance measurement. LCR bridge control is provided with 4 terminal multiplexing in order to add precision capacitance, inductance and resistance measurement capability. An integral H.V. capacitor bias option permits capacitance measurement to be made at up to 2.1kV.

  • Ground-Fault Location Products for Ungrounded Systems

    Bender Inc.

    When combined with Bender's ground-fault detectors and current transformers, EDS series modules provide fast, automatic ground-fault location in ungrounded systems. Fault location takes place while the system remains online without the need to open branch circuit breakers or disconnect equipment. Bender's fault location system works on both AC and DC systems, as well as systems with variable frequency drives. A standalone, portable fault location system is also available.

  • Aging and Optical Attenuation Tester

    LS822 - Lisun Electronics Inc.

    • Build-in DC Power Supply: Forward current preset: 0.1-800mA (special order) Range of forward voltage: 0.1-20.00V • Range of luminous intensity: 1mcd-3,000cd • Range of luminous flux: 1mlm-9,999,000lm(depends on the size of sphere) • Accuracy of photometer: class1; accuracy of electricity: class0.5 • Aging time: 9999Hours 59Munites 59Seconds • Tolerance of time: ±1S/10H • Record time: 16000times • Hold data automatically when the power is off and continue to work automatically when the power is turned on.

  • Electronic Circuit Breaker Unit

    Astronics Corporation

    The CorePower® DC or AC Electronic Circuit Breaker Unit replaces conventional thermal mechanical circuit breakers and functions as both a breaker and a switch for controlling loads. By placing ECBUs closer to loads, aircraft manufacturers gain a significant reduction in wire weight, need fewer system components, and lower installation labor costs while increasing safety, efficiency, and reliability. This new smaller unit requires less space and provides more flexible mounting options.

  • Frequency Demultiplexer

    Becker Nachrichtentechnik GmbH

    Modern receivers for broadcast have a large number of antenna inputs for the different radio bands. The devices of the FDMX series can be used to supply the antenna inputs with RF signals. The devices of the FDMX series splits a sum signal in frequency division multiplex into the individual broadcast bands and the L1 satellite navigation band (GNSS). Additionally, DC loads are provided for each antenna input to simulate active antennas. The presence of remote power supply is indicated by an LED on the units.

  • High Impedance Active Probes

    12C - Picoprobe

    A high speed, high input impedance active probe for measuring the internal node voltage of integrated circuits. The input is 1 megohm shunted by 0.1 pf and the rise/fall times are 0.8 ns. This instrument has full dc capability and can be used with any oscilloscope. The Model 12C was specially designed so that when used in conjunction with a high input impedance oscilloscope, signal attenuation is 10:1 and with a 50 Ohm input, signal attenuation is 20:1.

  • PXIe-4112, 2-Channel, 60 V, 1 A PXI Programmable Power Supply

    782857-01 - NI

    The PXIe‑4112 is a programmable DC power supply with isolated outputs. It helps simplify the task of designing automated test systems for a wide range of applications—from aerospace and defense to automotive and component test—by eliminating the need to mix multiple instrumentation form factors in a given test rack. It also has standard output disconnect functionality that allows isolation from the device under test (DUT) when not in use, and remote sense to correct for losses in system wiring.

  • PXIe-4113, 2-Channel, 10 V, 6 A PXI Programmable Power Supply

    782857-02 - NI

    The PXIe‑4113 is a programmable DC power supply with isolated outputs. It helps simplify the task of designing automated test systems for a wide range of applications—from aerospace and defense to automotive and component test—by eliminating the need to mix multiple instrumentation form factors in a given test rack. It also has standard output disconnect functionality that allows isolation from the device under test (DUT) when not in use, and remote sense to correct for losses in system wiring.

  • Dual LGA3647-P0 Intel® Xeon® Scalable EATX Server Board with 24 DDR4, 5 PCIe x16 + 1 PCIe x8, 10 SATA3.0, 6 USB3.0, Dual 10GbE, IPMI

    ASMB-935 - Advantech Co. Ltd.

    - EATX server board with dual Xeon Scalable processors- DDR4 2933 MHz RDIMM up to 3TB, support Intel Optane DC Persistent Memory- Five PCIe x16 (Gen3) and one PCIe x8 (Gen3) for three double-deck cards- Intel® X557-AT2 dual 10GbE ports- Ten SATA3.0 and six USB3.0 ports- One M.2 2280 (SATA / PCIe compatible)- 0 ~ 40 °C ambient operating temperature range

  • Phase Noise Analyzers

    Rohde & Schwarz GmbH & Co. KG

    The phase noise analyzer portfolio from Rohde & Schwarz offers an affordable, mid-range solution with high sensitivity and fast measurements as well as high-end ultra-high-sensitivity solutions with advanced measurements modes. Ideal for phase noise analysis and VCO tests, the industry-leading solutions enable two-path phase noise analysis with real-time cross correlation and fast VCO characterization with built-in low-noise DC sources. Additionally, high-end signal and spectrum analysis can be added into a single box.

  • Portable Multifunction Calibrator

    M143 - Clarke-Hess Communications Research

    The M143 Multifunction calibrator is a cost saving solution for calibration of electric meters with up to 1000 V and 20 A. It offersa basic accuracy of 0.01% in DC voltage for calibration of 3 and 4 digit multimeters. The resistance function is covered byeight fix resistors in range from 10 to 100 M. The calibrator offers TC temperature sensor simulation. It can be deliveredoptionally as well with RTD temperature sensor simulator. Thanks to its small dimensions and low weight the unit can be usedeasily for field calibration work.