Showing results: 2146 - 2160 of 3691 items found.
-
MC Model -
PJ Electronics, Inc.
Digital Surge, DC Hi-Pot & Built-In 3 Phase Test Selector Switch all-in-one versatile Tester. The DC Hi-Pot tester has separate panel meters for direct readout (voltage and current) so that no interpretation on the scope's display is ever needed and enables one to ascertain Polarization Index (PI) Test results.
-
DMT-4010RMS -
Monacor International GmbH & Co. KG
*True RMS measurement method*Dust and water protection according to IP class 67 with covered measuring sockets*Auto ranging for faster measurements*4000 digit resolution*Additional bar display*Voltage measurement up to DC/˜ 1000 V*Current measurement up to DC/˜ 10 A*Frequency measurement up to 10 MHz*Resistance measurement up to 40 MΩ*Capacitance measurement up to 40 mF*Temperature measurement -20 °C to +760 °C*Acoustic continuity test*diode test*Data hold (measured value memory)*peak hold*Maximum and minimum value recording*LC display with switchable background lighting*Automatic shutdown*overload protection*Supplied with test leads and protective case
-
460 -
Oersted Technology
The Model 460 is a 3-channel, high-resolution gaussmeter, for use with single or multi-axis probes. It is capable of measuring magnetic fields from 0.001 Gauss to 300kGauss, with a DC accuracy +/- 0.10%. This unit is designed for demanding applications, such as material analysis and field mapping, where low-noise, high-resolution magnetic measurements are necessary. Measurements of AC and DC magnetic fields are shown in Gauss or Tesla on the two-line vacuum fluorescent display. The Model 460 features RS232C and IEEE-488 ports, allowing the instrument to be controlled via a remote computer or automation equipment. The Model 460 can be used with a 3-axis probe or with three separate single-axis probes, effectively providing three Model 450 gaussmeters in one instrument. Probes are sold separately, and are available in a wide range of constructions.
-
HH2702 -
Colluck Company Limited
Basic Accuracy 4.0%. 5 Functions / 18 Ranges. Voltage test up to AC750V and DC 750V. Higher Current test up to 10A. Resistance test R X 1KΩ. Test Batteries 1.5V and 9V. Power: 2 x 1.5V "AA" battery
-
RD-22 -
Radian Research, Inc.
The RD-22 Dytronic Primary Transfer Standard represents the state-of-the-art technology in a commercially available true DC to AC accuracy transfer reference. The RD-22 has typical AC measurement accuracies within the limits of traceability. Repeatability of 1 ppm can be attained at 120 V and 5 A inputs of specific models.
-
GPS121 -
INSTOCK Wireless Components, Inc
Wideband Frequency (1000-2000 MHz)Low Insertion Loss (0.6 dB avg)High Port to Port Isolation (30 dB avg)Excellent VSWR (1.15 : 1 avg)15 VDC & 75 mA Max on DC Block PortsTri Alloy SMA Female (Jack) Low PIM
-
GPS161 -
INSTOCK Wireless Components, Inc
Wideband Frequency (1000-2000 MHz)Low Insertion Loss (0.6 dB avg)High Port to Port Isolation (30 dB avg)Excellent VSWR (1.15 : 1 avg)15 VDC & 75 mA Max on DC Block PortsTri Alloy SMA Female (Jack) Low PIM
-
Nanjing ELIKE Meter Co, Ltd.
DC current: 25/250mADC voltage: 0.5/2.5/10/50/250/500VAC voltage: 10/50/250/500VResistor: R x 1/R x 10/R x 1kSpecial functions:Low battery displayAnti-drop protective pouchesMulti-protective circuitGeneral characteristics:Colors: grey and yellowNet weight: approximately 130gWindows size: 54x44mmSize: 110x76x25.5mmPower: 1 x 1.5V, 7#
-
Model TWH -
Kusam Electrical Industries Limited
• Aux. Power AC 85 ~ 265V or DC 85 ~ 300V• High Accuracy 0.1% RO at 23 ° C ± 5 °C• Input / Output User Selectable• PC Plastic Case, DIN Rail or Wall Mounting• High Dielectric Strength (AC 1.5KV/Min, between Input / Output / Power)
-
HVP-40DM -
PINTEK Electronics
*DC 40KV CAT II Pollution 2.*2000MΩ Impedance.*3999 LCD display.*Accuracy 1.0% full range.*T.C. 100 ppm/oC*400V/4KV/40KV, 3 range.*Resolution 0.1V/1V/10V.*PEAK HOLD, Auto power off.*CE, TUV GS, UL, CUL, IEC1010
-
MZC-304 -
Sonel S.A.
# Measurements of impedance in a short circuit loop.- L-PE circuit,- L-N, L-L circuit,- L-PE(RCD) circuit - without tripping the circuit breaker > 30mA.# Low voltage resistance measurement:- continuity measurement - DC current +200mA with wire resistivity reset- low current resistance measurement with accoustic signalling,
-
Model TWL -
Kusam Electrical Industries Limited
• Aux. Power AC 85 ~ 265V or DC 85 ~ 300V• High Accuracy 0.1% RO at 23 °C ± 5 °C• Input / Output User Selectable• PC Plastic Case, DIN Rail or Wall Mounting• High Dielectric Strength (AC 1.5KV/Min, between Input / Output / Power)
-
HH2205K -
Colluck Company Limited
Basic Accuracy 1.0%. Jumbo LCD display 2000 count, 23.5mm figure heigh. Manual Ranging at your choice (19 Range). Rated CAT II 1000V. High Voltage test up to AC 750V and DC 1000V. Higher Current test up to 10A (fuse protected)
-
Model TWP / TWP2 -
Kusam Electrical Industries Limited
• Aux. Power AC 85 ~ 265V or DC 85 ~ 300V• High Accuracy 0.1% RO at 23 ° C - 5 °C• Input / Output User Selectable• PC Plastic Case, DIN Rail or Wall Mounting• High Dielectric Strength (AC 1.5KV/Min, between Input / Output / Power)
-
HMP4000 -
Rohde & Schwarz GmbH & Co. KG
The R&S®HMP DC Power supplies are primarily designed for industrial use. With three or four output channels and up to 10 A output current per channel, these rugged instruments are ideal for a wide variety of applications. They offer high efficiency with low residual ripple and many protection functions.