High Power Pulse Instruments GmbH

High Power Pulse Instruments GmbH (HPPI) is a supplier of ESD measurement equipment based on advanced Transmission Line Pulse (TLP) techniques. Our products enable the characterization of semiconductor devices and circuits in the pulsed high current and high voltage time domain.

  • +49(0)89 /878 06 98 – 440
  • +49 (0)89 / 878 06 98 – 444
  • info@hppi.de
  • Stadlerstrasse 6A
    Haar, D-85540
    Germany

Filter Results By:

Products

Applications

Showing results: 1 - 15 of 29 items found.

  • CC-TLP Probe

    CC-TLP-50-A1 - High Power Pulse Instruments GmbH

    *Capacitively coupled TLP probearm (CC-TLP) compatible with standard probing stations*18 GHz SMA connector*Tilt angle adjustment*Calibration gauge for needle height

  • Compact TLP/VF-TLP/HMM Probearm Set for Temperature Measurements

    PHD-4001A - High Power Pulse Instruments GmbH

    *Electrically isolated probearm kit for VF-TLP, TLP, HMM, HBM force and sense probingbased on the GGB Picoprobe Model 10 replacement probe tips*Buried coaxial cable channel for thermo-chuck in isolated chamber temperature measurements*Compatible with GGB Picoprobe Model 10 replacement probetips*Compatible with all standard micropositioner interfaces*High precision rotation of the probearm by backlash-free 80:1 gear*Rugged stainless steel design*SMA connectors

  • Flexible Pitch GND Fixture Clamps

    GF-A - High Power Pulse Instruments GmbH

    *Compatible with GGB picoprobe model 10 replacement probe tips*<1 ns rise time (200 ps possible with 5 mm GND wire length)*Custom selectable GND wire length 5-15 mm*Gold-coated spring-steel clamp with micro-machined groove for locking of the clamps on the probe tip*High conductivity and low inductance copper HF litz wire with 200 x Ø 0.02 mm strands*Easy to use clamping*Tungsten carbide probe needle with 1 inch length, 15° taper and 7.5 µm tip radius

  • Flexible Probearm for HBM and Flex-Pitch Applications

    TPA-GFG - High Power Pulse Instruments GmbH

    *Electrically isolated probearm for GND needle contact or general purpose DC, twin-wire HBM or flexible pitch VF-TLP/TLP/HMM/HBM force/sense probing based on the HPPI GF-A flexible pitch setup.*Flexible rotation of the probearm by precision gear 80:1*Suitable to mount the GF-A ground fixture needle for flexible pitch measurements. In addition a cable (e.g. for HBM) can be directly connected to the contact pin.*High stability

  • Manual Probearm for HBM and Flex-Pitch Applications

    TPA-GFM - High Power Pulse Instruments GmbH

    *Electrically isolated probearm for GND needle contact or general purpose DC, twin-wire HBM or flexible pitch VF-TLP/TLP/HMM/HBM force/sense probing based on the HPPI GF-A flexible pitch setup.*Suitable to mount the GF-A ground fixture needle for flexible pitch measurements. In addition a cable (e.g. for HBM) can be directly connected to the contact pin.*High stability

  • Portable Wafer Probe Station

    PS-5026B - High Power Pulse Instruments GmbH

    The PS-5026B is a rugged portable wafer probing solution which has been designed for high reliability, compact size and minimum cost.

  • Precision Picoprobe™ Micropositioner Probe Holder Kit

    PHD-3001A - High Power Pulse Instruments GmbH

    *Pulse force and pulse sense fixed pitch and flexible pitch RF probing solution for TLP/VF-TLP/HMM on-wafer measurements using Picoprobe™ Model 10*High peak current capability 80 A (100 ns)*DC – typ. 7 GHz bandwidth*Isolated probe-head ground shield for high pulse sense common mode signal rejection*Including fixed pitch replacement probe tip 50 Ω, right, 100 µm pad pitch*Including fixed pitch replacement probe tip 5 kΩ, left, 100 µm pad pitch*Including flexible pitch clamps plus 10-5k(0502)-125-W-1 and 10-50/30-125-W-1 replacement probe tips*True coaxial high-resolution 80:1 rotary probe-head for accurate probe tip adjustment

  • Pulse Width Extender

    TLP-3011C - High Power Pulse Instruments GmbH

    *Fully automatic pulsewidth extender*Pulse width up to 1.6 µs in 68 programmable steps of 25 ns*Ultra fast 50 Ω pulsewidth extension with typical 100 ps rise time*High pulse output current up to ±40 A*High performance and high quality components

  • TLP Probe Arm Kit

    TPA-95 - High Power Pulse Instruments GmbH

    *Flexible pulse force, pulse sense combined TLP probe arm kit based on TPA-95L and TPA-95R*Compatible with typical standard micropositioner mechanical interfaces*4.7 kΩ pulse sense voltage divider, which results in a voltage transfer ratio of (4700 + 50)/50 = 95 : 1 into 50 Ω*Variable probe pitch configuration*1 m flexible 50 Ω cables with SMA connector for pulse sense*0.1 m flexible 50 Ω cables with SMA connector for pulse force*Tungsten probe tips*Can be used for chuck backside grounded TLP measurements

  • 48 Ω HMM Pulse Force Probe

    PHD-HMM-48-1 - High Power Pulse Instruments GmbH

    *High current wafer-level and package-level 98 Ω HMM probing with grounded DUT*Built-in high surge 48 Ω pulse reflection suppression resistor up to 80 A peak*Fast rise time < 0.5 ns due to low inductance GND loop*Variable pitch from 50 µm to 5 mm*Tungsten replacement probe tips*SMA pulse force pigtail*Compatible to PHD-3001A interface*High reliability

  • High Voltage 50 Ω Pulse Generator

    TLP-8010A - High Power Pulse Instruments GmbH

    *Wafer and package level TLP/HMM testing*Fast 50 Ω high voltage pulse output with typical 300 ps rise time*Up to 80 kW peak output power into 50 Ω load*Built-in HMM pulse up to ±15 kV with 50 Ω-configuration*High pulse output current up to ±80 A (short circuit) with 6 dB reflection suppression*High speed 50 Ω trigger output for oscilloscopes (synchronous to high voltage pulse output)*6 GPIB programmable pulse rise times: 300 ps to 50 ns*1 built-in pulse width: 100 ns*Optional external pulse width extensions 5/10/50/100/200/500 ns using an external pulse width extender TLP-8012A5*Fast measurement time, typically 0.2 s per pulse including one-point DC measurement between pulses*Efficient software for system control and waveform data management*The software can control automatic probers for fast measurements of complete wafers*High performance and high quality components

  • High Voltage 50 Ω Pulse Generator

    TLP-3010C - High Power Pulse Instruments GmbH

    *Wafer and package level TLP/VF-TLP/HMM testing*Ultra fast 50 Ω high voltage pulse output with typical 100 ps rise time*Built-in HMM (IEC 61000-4-2) pulse up to ±8 kV*High pulse output current up to ±30 A*High speed 50 Ω trigger output for oscilloscopes (synchronous to high voltage pulse output)*6 programmable pulse rise times: 100 ps to 50 ns*8 programmable pulse widths: 1 ns to 100 ns*Optional pulse width extender increases pulse width up to 1.6 µs in 68 programmable steps*Fast measurement time, typically 0.2 s per pulse including one-point DC measurement between pulses*Efficient software for system control and waveform data management*The software can control automatic probers for fast measurement of complete wafers*High performance and high quality components

  • High Voltage 50 Ω Pulse Generator

    TLP-4010C - High Power Pulse Instruments GmbH

    *Wafer and package level TLP/VF-TLP/HMM testing*Ultra fast 50 Ω high voltage pulse output with typical 100 ps rise time*Built-in HMM (IEC 61000-4-2) pulse up to ±10 kV*High pulse output current up to ±40 A*High speed 50 Ω trigger output for oscilloscopes (synchronous to high voltage pulse output)*6 programmable pulse rise times: 100 ps to 50 ns*8 programmable pulse widths: 1 ns to 100 ns*Optional pulse width extender increases pulse width up to 1.6 µs in 68 programmable steps*Fast measurement time, typically 0.2 s per pulse including one-point DC measurement between pulses*Efficient software for system control and waveform data management*The software can control automatic probers for fast measurement of complete wafers*High performance and high quality components

  • High Voltage 50 Ω Pulse Generator

    TLP-8010C - High Power Pulse Instruments GmbH

    *Wafer and package level TLP/VF-TLP/HMM testing*Combines TLP-8010A and TLP-4010C into one system*Can be operated together with TLP-8012A5 and TLP-3011C pulse width extenders*Ultra fast 50 Ω high voltage pulse output with typical rise time 100 ps (0-40 A) and 300 ps (> 40 A)*Up to 80 kW peak output power into 50 Ω load*Built-in HMM pulse up to ±15 kV with 50 Ω configuration*High pulse output current up to ±80 A (short circuit) with minimum 6 dB reflection suppression*High speed 50 Ω trigger output for oscilloscopes (synchronous to high voltage pulse output)*6 GPIB programmable pulse rise times: 100 ps to 50 ns*8 programmable pulse widths: 1 ns to 100 ns (0-40 A), 1 built-in pulse width: 100 ns (> 40 A)*The optional pulse width extender TLP-3011C enables pulse width up to 1.6 µs in 68 GPIB programmable steps (0-40 A)*Optional external pulse width extensions from 5 ns to 500 ns (> 40…80 A) using the external pulse width extender TLP-8012A5*Built-in pulse reflection suppression*Fast measurement time, typically less than 0.2 s per pulse including one-point DC measurement between pulses*Efficient software for system control and waveform data management*The software can control automatic probers for fast measurements of complete wafers*High performance and high quality components

  • 120 A Manual Pulse Width Extender

    TLP-12012A6 - High Power Pulse Instruments GmbH

    - Pulse width extender for the high current TLP/HMM test system TLP-12010A and TLP-12010C- 6 manual selectable pulse width: 5, 10, 50, 100, 200 and 500 ns- High pulse output current up to ±120 A- High performance and high quality components

Get Help