Showing results: 766 - 780 of 867 items found.
-
8761A -
Keysight Technologies
The Keysight 8761A is a single-pole, double-throw coaxial switch with excellent electrical and mechanical characteristics for 50 ohm transmission systems operating from dc to 18 GHz. It features broadband operation, long life, low SWR, excellent repeatability, and magnetic latching solenoids. The Keysight 8761A switch is small and lightweight, making it ideal for applications where space is limited. Because of its versatility and excellent electrical performance, it is well suited for automated testing and systems applications.
-
Recon® V Ultra Lite -
Teledyne FLIR
Fully operational at less than three pounds, the breakthrough Recon V Ultra Lite provides mid-range target detection, recognition, recording and geo-location with an HD color camera and high sensitivity thermal channels. Powered by commercially available AA batteries, the unit has a run time greater than two and a half hours with smart power management. Combining with a highly accurate laser range finder, GPS, digital magnetic compass and intuitive user interface, targets can be quickly located 24/7.
-
OM-1500/1200 -
Ono Sokki
The OM-1500/1200 motor/gasoline engine RPM detector is designed for rotation measurement of a gasoline engine and an EV/HEV motor. It detects magnetic flux leakage from the motor itself or the engine’s ignition coil.This easy to use and durable detector can measure engine rotation by attaching in parallel with the ignition coil. When the EV/HEV motor rotation is measured, attach the OM-1500/1200 perpendicular to the motor rotating shaft.It is used with the engine tachometer by Ono Sokki (GE-2500, AR-7240B, CT-6520B, HT-6200, SE-1620, FT-2500, FT-7200).
-
HS6-DIFF-1000XMEGS-W -
TEAM SOLUTIONS, INC.
The powerful capabilities of the WiFiScope HS6-DIFF-1000XMEGS EMI analyzer give the user the possibility to quickly perform a good EMI compliance test. With this cost effective test, time and money are saved by avoiding extra visits to expensive EMC testing facilities. The supplied EMI probe set TP-EMI-HS6 contains three magnetic field (H field) probes and one electric field (E field) probe. The tripod ensures that the probes can be positioned properly at the object under test.
-
HS6-DIFF-1000XMEG-W5 -
TEAM SOLUTIONS, INC.
The powerful capabilities of the WiFiScope HS6-DIFF-1000XMEG EMI analyzer give the user the possibility to quickly perform a good EMI compliance test. With this cost effective test, time and money are saved by avoiding extra visits to expensive EMC testing facilities. The supplied EMI probe set TP-EMI-HS6 contains three magnetic field (H field) probes and one electric field (E field) probe. The tripod ensures that the probes can be positioned properly at the object under test.
-
STMicroelectronics
Protection against electrostatic discharges (ESD) is part of EMC Immunity (Electro Magnetic Compatibility) requirements. It is the ability for equipment to properly operate in its electromagnetic environment by limiting the reception of electromagnetic energy that may cause physical damage. ESD can be either conducted under the form of a transient voltage or can be radiated due to its fast rising time: powerful harmonics will generate erratic behavior by the application by coupling with other signals. Printed circuit boards must be protected against the effects of electrostatic discharge.
-
MR 8050 -
Schuetz Messtechnik GmbH
With the MR 8050 resistances highly inductive Resistance Meters windings of transformers, motors and reactors can be measured. (range 100 µΩ with 0.01µΩ resolution up to 6 kΩ). The performance of the test objects can be up to 800 MVA or even more. The magnetic loading of a transformer is performed quickly using a high loading voltage (60V). This is important for time critical measurements (cooling curves). The unloading of the transformers core is very fast, very safe, as the energy is total destroyed in the MR 8050.
-
LBA Group, Inc
EMI (Electromagnetic Interference) is often used interchangeably with RFI (Radio Frequency Interference). However, EMI can be any frequency of electromagnetic noise, whereas RFI is a relatively narrow range of electromagnetic noise on the EM spectrum. EMI Shielding can be used to mitigate electric and magnetic radiation across various spaces. Radio Frequency (RF) Shielding can be used to mitigate RFI with specifically designed enclosures that can block RFI. As well, RF Shielding can include application of RF Shielding paints, fabrics, and other materials.
-
TWA Advanced Series -
Amperis sl
The TWA advanced series instruments are designed for six-winding resistance measurement and simultaneous three phase on-load tap changer analysis of both the primary and the secondary transformer windings. This is performed with a one singlestep cable setup, with test currents of up to 40A. Each transformer configuration has a special measurement algorithm which is optimized for the fast stabilization of test results. The TWA instruments generate a true DC ripple-free current. Both the injection of the current and the discharge of energy from the magnetic circuit are automatically regulated.
-
TWA Standard Series -
Amperis sl
The TWA standard series instruments are designed to measure the resistance of six coils and simultaneously analyze the three-phase tap changer on load of the primary and secondary transformer coils (provided by model TWA40). This is done in a single cable configuration, with test currents up to 40A. Each transformer configuration has a special measurement algorithm that is optimized for rapid stabilization of test results. The TWA instruments generate a true DC current without ripple. Both current injection and magnetic circuit energy discharge are automatically regulated.
-
LXinstruments GmbH
In the past, LXinstruments has already implemented a number of application-specific system solutions which cater for these special requirements. These solutions are often used to replace systems which have been in production for many decades. Our systems are not only employed for testing signal box technology modules, but also for testing train control system which are installed in the track bed. Due to the strong magnetic fields which occur at the DUT in combination with high voltages, the test systems require specific technical safeguards.
-
Analog Devices Inc.
Analog Devices’ family of isolated I2C isolators support a complete isolated I2C interface. This portfolio is based on our iCoupler® chip scale transformer technology. iCoupler is a magnetic isolation technology with functional, performance, size, and power consumption advantages compared to optocouplers. By integrating iCoupler channels with semiconductor circuitry, our technology enables a complete, isolated I2C interface with a small form factor. Our I2C isolators covers applications such as central office switching, networking, and power over Ethernet.
-
UL 30 -
BAUR Prüf- und Messtechnik GmbH
Cable fault location with the BAUR UL 30. The UL 30 receiver is used together with a ground microphone (BM 30) and a surge voltage generator (SSG, STG) to pinpoint cable faults. With the coil integrated in the BM 30 for runtime measurement, the device determines the time difference between the magnetic and acoustic signal. This particularly offers special advantages when d ealing with faults difficult to locate acoustically.* Built-in speaker* Splashproof design* Large, illuminated display* Lightweight
-
B-1026 -
ROSS ENGINEERING CORPORATION
Ross Engineering Corporation has developed and manufactures a line of Electrostatic Discharge (ESD) testers. One model is designed for explosive proof testing per MIL-I-23659C, Paragraph 4.4.3.2 static discharge test. It incorporates high voltage electro magnetic or air pressure operated relays to safety ground, charge, and dump capacitors into the appropriate device under test. This ESD tester is a portable system utilizing 120V AC power. It is a high reliability device capable of many thousands of cycles.
-
Rocky Mountain Laboratories, Inc.
Scanning probe microscopy (SPM) refers to a family of measurement techniques that utilize a scanning probe. The most common measurement is Atomic Force Microscopy (AFM Analysis), which measures surface topography. Imaged areas can be from the nm scale to as large as 100 µm X 100 µm. Heights and depths of features can be measuredand many surface roughness parameters, e.g Ra, can be calculated. 3-D images can also be produced for dramatic data presentation. Magnetic and electrical response can also be measured with SPM.