Showing results: 361 - 375 of 868 items found.
-
SU63 -
Validyne Engineering
The Validyne SU63 is an AC inductive speed pick-up used for RPM measurement on high-speed rotating equipment. The SU63 is a tightly-wound coil with a laminated core that can be conveniently mounted on rotating equipment so that the magnetic field of a magnetized nut or part passes through the coil windings. The moving magnetic field produces a voltage within the coil proportional to its rate of change and the strength of the permanent magnetized part. The frequency of this inductive voltage spike is fed into an oscilloscope or counter to determine RPM.
-
Bruker Corporation
Bruker offers advanced preclinical imaging solutions for a broad spectrum of application fields, such as oncology, neurology, cardiology, inflammation, infectious diseases, cancer research, functional and anatomical neuroimaging, orthopedics, cardiac imaging and stroke models. Our range of techniques includes MRI (Magnetic Resonance Imaging) , PET (Positron Emission Tomography), SPECT (Single Photon Emission Computed Tomography) micro-CT (Micro Computed Tomography), optical imaging and magnetic particle (MPI) imaging.
-
KOERZIMAT® 1.097 HCJ/J-H -
Foerster Instruments, Incorporated
Magnetic values such as coercivity HCJ correlate with numerous important process parameters and material properties in the production of sintered hard metals and powder-metallurgical components. The KOERZIMAT 1.097 HCJ measuring system by FOERSTER facilitates the accurate, automatic, and fast measurement of the coercivity HCJ. The largely geometry-free measurement is particularly suitable for testing samples with complex shapes. The extension module J-H measurement offers the possibility to determine the complete J-H Hysteresis on soft magnetic steel incl. the initial curve.
-
KO 3.1 -
MAGMESS Magnet-Messtechnik
For measurement of the coercive field strenght of soft magnetic materials. Digital display of the measured values. Measurement of small workpieces is also possible. Options: PC connection and plotter software.
-
MAGMESS Magnet-Messtechnik
To be used in research, or as magnetizers to generate magnetic field strenghts up to 3 T. The airgap can be adjusted via hand wheel. The pole pieces are exchangable. Water cooling is possible.
-
Omega Engineering, Inc
Magnetic flow meters, also known as electromagnetic flow meters or mag meters, are often selected because they are obstruction less, cost-effective, bi-directional, and highly accurate flow meters.
-
BioPlex® 2200 -
Bio-Rad Laboratories
The BioPlex 2200 fully-automated, random access, multiplex testing platform uses sets of magnetic beads coated with ligands as the basis for a range of autoimmune, infectious disease, and other immunoassays
-
WFG-D-120A -
Wuntronic GmbH
The Model WFG-D-120 magnetometer is a tri-axial vector magnetometer system with a high-speed digital interface that can transmit XYZ magnetic field values at up to 140 times per second.
-
Intusoft
Combines the ICAP/4Windows Power Deluxe tool suite (above); Magnetics Designer for the design and synthesis of all types of transformers and inductors; and Library Manager parts management system.
-
Ferrites India
Magnetostriction is a phenomenon where the sample is applied a magnetic field and change in its physical dimensions are measured using a strain gauge. Typical output of Magnetostricion measurement is shown below.
-
-
Sheen Instruments
Using the magnetic attraction principle, this traditional gauge offers reliable thickness measurement of coatings, electroplating, enamel, rubber, electroplated nickel on steel, or electroplated nickel on non-ferrous substrates.
-
ENVIROMUX-M-DCS -
Network Technologies Inc
Monitors access with a magnetic bridge sensor, which responds to any magnetic material (no special inserts necessary). Can also be used for monitoring side wall and covers. Includes mounting hardware. For normally closed circuit connection. 2-wire interface. Screw terminal. Maximum cable length: 1,000 ft. Wide actuating gap, approximately 1". Dimensions WxDxH (in): 0.5x0.5x2 (Switch), 0.5x0.5x2 (Magnet). Operating temperature: 32 to 158°F (0 to 70°C). Regulatory approvals: RoHS.
-
Kobold Instruments, Inc.
Magnetic level switches are used for the monitoring and control of liquid level in tanks. These level switches are specifically manufactured to customer specifications. The float switches are manufactured with a hermetically sealed contact which is located within the guide tube. The float sliding on the tube contains a ring magnet which activates the sealed contact in a non-contacting fashion. The sealed contacts are available as SPST (N/O or N/C) or SPDT (N/O + N/C). The float sliding up and down on the guide tube is the only moving part on the M-series magnetic float switches.
-
McLAREN Applied Technologies
DHE (Differential Hall Effect) sensors give an output when subjected to a changing magnetic field. The field is set up by a magnet inside the sensor body and changes when ferromagnetic teeth are passed beneath the sensor (no magnets are required in the target). To improve noise resistance, the sensor has two Hall effect elements and only responds to changes in magnetic field strength corresponding to tooth passing frequencies above 15Hz. As each tooth passes the sensor, the digital state of the output changes.