Showing results: 1 - 15 of 23 items found.
-
VCL -
Veer Electronics
Core loss testing has become one of the most important tests for quality assurance in the motor industry. The function of a core loss test is to determine weather a motor has damaged core iron. Damage could include shorts between laminations and electrical arching. Although it is possible for a motor to still run with damaged core but the efficiency of that motor will be greatly reduced. The Motor will consume more power to operate at normal levels and it will cause the Motor to generate more heat. Heat will reduce the reliability of the motor and its overall life. VEER make Core Loss Tester is portable & easy to use instrument which is very useful to measure AC magnetic properties of Electrical steel of core of different grade and size. We provide Free Computer software along with instrument to create test report in computer.
-
S30 and S30S Series -
Ferrites India
Stacks built with punched laminations can have a lot of quality issues. Even though the lamination material is tested in sheet format before any process, that alone is not sufficient to guarantee good quality stators. Wear and tear of the punch, bad welding, bad insulating coating in annealing add to the magnetic losses in the stator. It is always advisable to test the stator core in it's final format before winding to ensure good quality throughout the production batch.
-
-
SS-SML01 -
Sanshine Electronis Co., Ltd.
This SS-SML01 soft magnetic core power loss analyzer includes one set broadband power signal generator and on set W-A-V meter, the broadband power signal generator is specially researched and manufactured for the testing of the soft magnetism materials.
-
Anfkom International Co.,Limited
This test station do the auto-testing on 12 core(24 core) for insertion loss and return loss, highly efficient multi-core fiber insertion and return loss measurement and make high precision on the measurement result with OTDR mandrel free technical adopting.
-
DX-2012M -
Dexing Magnet Tech. Co., Ltd
Automatic measurement of the dynamic magnetic hysteresis loop of oriented and non-oriented silicon steel under the condition of 50 Hz, 60 Hz, 400 Hz and 1 kHz, accurate measurement of the static magnetic characteristic parameters such as amplitude permeability μa, loss angle δ, specific total loss Ps, remanence Br and coercivity Hc. With special testing fixture, it can directly measure the iron core and stator core of the transformer.
-
Model DW22 -
Gopal Electronics
Digital Iron Loss Tester Dw22 is single sheet core loss tester which is useful to evaluate iron loss of electrical steel sheet CRGO, CRNO material and suitable for testing EI lamination, Motor Stamping, Fan motor stamping etc. Single sheet tester is suitable for quick & tentative idea of iron loss of sample. however for precision measurement user has to use Epstein Tester.
-
Anfkom International Co.,Limited
Low insertion loss, high return lossMT based Multi-fiber Connector up to 12 fibersHigh credibility and stabilityGood in repeatability and exchangeabilityStandard: Telcordia GR-1435-CORE compliant
-
DX-30SST -
Dexing Magnet Tech. Co., Ltd
DX-30SST Silicon Steel Sheet Iron Loss Meter adopts SCM technique and analog electronics technique, the magnetic circuit of permeameter adopts low loss silicon steel iron core, it is a small tester for measuring the characteristics of silicon steel sheet, met the requirements of tracing the brand of silicon steel sheet.
-
2400 -
Photon Kinetics
The 2400 Fiber Geometry System is designed to provide high-speed automated measurements of optical fiber end-face geometry. Repeatable and accurate measurement of parameters such as core and cladding diameter, core and cladding non-circularity, as well as core-cladding concentricity provide invaluable process control information, and ensure that customer demands for low loss fiber splices are satisfied. Measurement options are available for both side view coating geometry measurement and fiber curl characterization.
-
IWATSU Electronic Co., Ltd.
Precise and accurate core loss measurementIwatsu's B-H analyzers which hiring CROSS-POWER method (IEC62044-3)enable precise and highly accurate measurement embedded minimized phase error integration on frequency spectrum with current detecting resisters and compensation on detecting circuit with full compensation on amplitude and phase characteristics.
-
Saluki Technology Inc.
SFS-2000H series is the core-to-core alignment (6 motors) fusion splicer. Light Weight, Touch Screen, Friendly UI, Fast Fusion and Heating, and more intelligent. The rich functionality and ultra-low splice loss make the splicer adaptive to fiber splicing in various environments.* Core to core alignment (6 motors)* 7s fast splicing, 14s highly efficient heating* 320/200 times image magnification, 5mm fusing for ultra-short cleave length* 10000 groups and 100 images of fusion records storage* 300 groups of splice modes, 100 groups of heating modes* 300 counts of splicing and heating cycles with build-in 6800mAh Li-on battery
-
MLS 7100 -
Schuetz Messtechnik GmbH
The MLS 7100 transformer loss measuring bridge was especially designed to greatly simplify the determination of transformer core and copper losses – an ideal choice when working on site. The measuring bridge features open circuit as well as short circuit measuring. Many transformers can be directly connected to the MLS 7100 without needing further transducers.
-
UI9730 -
Lisun Electronics Inc.
Parameters to be measured (absolute value): Measure hypo-class U, Iout, Hz, Hc, Br, Bm, Hm, Br /Bm, μm, magnetic core loss, B-H curve, U curve and I curve• Output capacity of the high frequency power: Uout: 1~300V, Iout: 0.05~5A, Pout: 300VA, frequency: 10~300kHz
-
CWM -
TOEI INDUSTRY CO, LTD.
The automatic measurement equipment to continuously measure magnetic property in commercial power frequency of magnetic steel sheet sample on line, is used for quality control. Core loss in definite time of magnetic flux density [B] or magnetic flux density [B] in definite time of strength of magnetic field [H] for excited magnetic steel sheet is measured on line.